Photoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left hand remained static. The pulse width, time to peak (TTP), the time to the maximum slope (TTMas) were computed from 30sec DPW signals at three positions of the right hand with regard to heart level, i.e. 35 cm above heart level (+35 cm), at the level of the heart (0 cm), and 35 cm below the level of the heart (-35 cm). DPW characteristics were found to alter with hand position. On lowering the hand to -35 cm relative to heart level, DPW width from the middle finger increased by (6%), but lowering the arm decreased the TTP (by 11 %), TTMas (by 18 %). These changes in time-dependent DPW indices may be attributed to changes in hydrostatic pressure and the venoarterial reflex that changes the blood vessels filling from completely filled one at -35 cm due to arterial vasoconstriction and decreased venous return to partially emptied blood vessels due to arterial vasodilatation and increased venous return at +35 cm. It was assumed that these time-dependent morphological DPW indices alterations were controlled by changes in downstream venous resistance rather than arterial or arteriolar, resistance. Keywords: photo plethysmography, hand elevation, vasoconstriction, vasodilation, vascular mechanics
One of the most important human diseases that need to be considered in terms of development of the medical engineering devices is cardiovascular disease which is a significant cause of death globally recently. Valvular heart disease is normally treated by restoring or altering heart valves with an artificial one. But the new prosthetic valve designs necessitate testing for durability estimate and failure method. It is significant to simulate the circulation system by the building of a pulse duplicator system. This study is stated by clarifying the parameter and implementation steps of the pulse duplicator system in which the different researchers have utilized the system and tried to explain the design steps of using this system wit
... Show MoreThe nuclear size radii, density distributions and elastic electron scattering charge form factors for Fluorine isotopes (17,19,20,24,26F) were studied using the radial wave functions (WF) of harmonic-oscillator (HO) potential and free mean field described by spherical Hankel functions (SHF) for the core and the valence parts, respectively for all aforementioned isotopes. The parameters for HO potential (size parameter ) and SHF were chosen to regenerate the available experimental size radii. It was found that using spherical Hankel functions in our work improved the calculated results quantities in comparison with empirical data.
The objective of this experiment was to determine the effects of dietary supplementation with different fat sources on blood parameters of Japanese quail (Coturnix coturnix japonica). Eighty four 7-week old laying quail were randomly assigned to 4 treatment groups (21 birds per group) with 3 replicates for each treatment group and fed for three months on a commercial diet supplemented with 3% of either sunflower oil (T1), flax oil (T2), corn oil (T3) or fish oil (T4). The birds received water and feed ad libitum during the experiment. During the last month of experiment blood samples were collected fortnightly from each bird. The first blood samples collection was used to determine fresh blood parameters, while the second blood samples coll
... Show MoreCongenital hand and forearm anomalies pose a unique challenge in plastic and pediatric surgery. We present a case report of an 8- months-old girl with a congenital left sided hand and forearm anomaly, provisionally diagnosed as atypical left mirror hand anomaly. Classically there is absence of radius and duplication of ulna; however, our case had normal radius and ulna and a hand with seven digits arranged in two groups. We did a surgery which involved a ray amputation of the finger ulnar to the most radial digit, aiming to preserve an adequate first web space to reconstruct the thumb. The result of the surgical treatment in both functional and cosmetic aspects was, in authors’ opinion, good.
This work is focused on the design parameters and activity of artificial human finger for seven grips. At first, obtained the ideal kinematics of human fingers motion by analyzing the grips video which were recorded using a single digital camera recorder fitted on a tripod in sagital plane while the hand is moving. Special motion analysis software (Dartfish) the finger joint angles were studied using the video recording. Then the seven grips were modeled using static torque analysis, which calculates the amount of torque applied on the fingers joint grip depending on the results of the kinematic analysis. The last step of the work was to design the actuator (Muscle Wire) of artificial finger for the seven grips in a simple design approac
... Show MoreIn this research velocity of moving airplane from its recorded digital sound is introduced. The data of sound file is sliced into several frames using overlapping partitions. Then the array of each frame is transformed from time domain to frequency domain using Fourier Transform (FT). To determine the characteristic frequency of the sound, a moving window mechanics is used, the size of that window is made linearly proportional with the value of the tracked frequency. This proportionality is due to the existing linear relationship between the frequency and its Doppler shift. An algorithm was introduced to select the characteristic frequencies, this algorithm allocates the frequencies which satisfy the Doppler relation, beside that the tra
... Show Moreالزكاة فريضة من فرائض الإسلام وعبادة من العبادات التي اقرها الشرع الإسلامي هذه الفريضة المالية التعبدية بالإضافة الى دورها المعنوي الذي يهدف الى إرساء قواعد العدالة الاجتماعية والقضاء على مشكلة الفقر في المجتمع الاسلامي وكما ينص عليها الدين الإسلامي فان لها ابعادها ووظائفها الكثيرة التي تخدم اليات العمل الاقتصادي في مجتمع يعمل وفق نظام اقتصادي أسلامي .
ان انفاق الاموال المتحصلة من فريض
... Show MoreProsthetic is an artificial tool that replaces a member of the human frame that is absent because of ailment, damage, or distortion. The current research activities in Iraq draw interest to the upper limb discipline because of the growth in the number of amputees. Thus, it becomes necessary to increase researches in this subject to help in reducing the struggling patients. This paper describes the design and development of a prosthesis for people able and wear them from persons who have amputation in the hands. This design is composed of a hand with five fingers moving by means of a gearbox ism mechanism. The design of this artificial hand has 5 degrees of freedom. This artificial hand works based on the principle of &n
... Show More