Preferred Language
Articles
/
HRfIYo8BVTCNdQwCFHU6
The Effect of Hand Blood Flow on the Peripheral Fingertip Plethysmographic Waveforms Morphology and Pulse Wave Velocity
...Show More Authors

Photoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left hand remained static. The pulse width, time to peak (TTP), the time to the maximum slope (TTMas) were computed from 30sec DPW signals at three positions of the right hand with regard to heart level, i.e. 35 cm above heart level (+35 cm), at the level of the heart (0 cm), and 35 cm below the level of the heart (-35 cm). DPW characteristics were found to alter with hand position. On lowering the hand to -35 cm relative to heart level, DPW width from the middle finger increased by (6%), but lowering the arm decreased the TTP (by 11 %), TTMas (by 18 %). These changes in time-dependent DPW indices may be attributed to changes in hydrostatic pressure and the venoarterial reflex that changes the blood vessels filling from completely filled one at -35 cm due to arterial vasoconstriction and decreased venous return to partially emptied blood vessels due to arterial vasodilatation and increased venous return at +35 cm. It was assumed that these time-dependent morphological DPW indices alterations were controlled by changes in downstream venous resistance rather than arterial or arteriolar, resistance. Keywords: photo plethysmography, hand elevation, vasoconstriction, vasodilation, vascular mechanics

Crossref
View Publication
Publication Date
Thu Feb 29 2024
Journal Name
International Journal Of Heat And Technology
The Effect of Wall'S Porous Liner on MHD Couette Flow of Carreau Fluid in an Inclined Channel under the Convective Conditions
...Show More Authors

View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Tracked Robot Control with Hand Gesture Based on MediaPipe
...Show More Authors

Hand gestures are currently considered one of the most accurate ways to communicate in many applications, such as sign language, controlling robots, the virtual world, smart homes, and the field of video games. Several techniques are used to detect and classify hand gestures, for instance using gloves that contain several sensors or depending on computer vision. In this work, computer vision is utilized instead of using gloves to control the robot's movement. That is because gloves need complicated electrical connections that limit user mobility, sensors may be costly to replace, and gloves can spread skin illnesses between users. Based on computer vision, the MediaPipe (MP) method is used. This method is a modern method that is discover

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Sun Jun 05 2016
Journal Name
The Iraqi Journal Of Veterinary Medicine
Effect of L-Carnitine and Niacin addition on some blood parameters of fry Common Carp Cyprinus carpio
...Show More Authors

    The present study was conducted in order to focus on the effect of the addition of Carnitine and Niacin on some blood serum parameters of Common Carp Cyprinus Carpio. 48 fish carp mean weight 44.13 gm were distributed randomly on four feeding treatments (12 fish each) with replicates (6 fish each) in 8 glass aquaria. Treatments were as follows: fish were fed on basic diet without any addition and conducted as control (T1); addition of 200 mg Carnitine/ Kg diet, (T2) addition of 28 mg Niacin/Kg diet (T3), addition of a mixture of 200 mg Carnitine and 28 mg Niacin/ Kg diet as (T4). The experiment was conducted for 70 days and the results showed an increase in the Cholesterol concentration of T1 (187.6 mg/ 100 ml) and differed s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
THE INFLUENCE OF SUPPLEMENTING ELLAGIC ACID TO BROILER DIETS ON PRODUCTIVITY AND WHITE BLOOD CELL DIFFERENTIAL COUNTS: THE INFLUENCE OF SUPPLEMENTING ELLAGIC ACID TO BROILER DIETS ON PRODUCTIVITY AND WHITE BLOOD CELL DIFFERENTIAL COUNTS
...Show More Authors

This study has been carried out in the animal field of the college of agricultural engineering sciences, university of Baghdad, for the period from 12/15/2021 to 1/26 /2022 for 42 d, to investigate the effect of adding different levels of ellagic acid to the diet of broilers, on some physiological characteristics &  oxidation indicators in meat compared to vitamin C in meat,  225 Ross 308 chicks were used, divided randomly to five treatments such us: T1: control group without additives to diet, &  the other T2, T3, T4 was added  ellagic  acid (

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 03 2015
Journal Name
Al-kindy College Medical Journal
Compound fractures of the hand metacarpals and phalanges treated by using mini-external fixator
...Show More Authors

Background: A review of articles of method in treating compound phalangeal fractures by using mini-external fixator, elaborating the anatomy, mechanics, modalities of treatment, and complications of these types of fractures. Also, it compares between different studies regarding the functional results and final outcome. External fixation of phalangeal fractures is a good method for osteo synthesis in certain situations. The simplicity of the surgical procedure and the minimal disruption of the normal bone architecture also make it appealing. Objectives: Evaluating the functional results of the use of mini-external fixator for the treatment of compound fractures of phalangeal bones of the hand. Method: Our study consists of 15 patients, 12 we

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Compound fractures of the hand metacarpals and phalanges treated by using mini-external fixator
...Show More Authors

Background: A review of articles of method in treating compound phalangeal fractures by using mini-external fixator, elaborating the anatomy, mechanics, modalities of treatment, and complications of these types of fractures. Also, it compares between different studies regarding the functional results and final outcome. External fixation of phalangeal fractures is a good method for osteo synthesis in certain situations. The simplicity of the surgical procedure and the minimal disruption of the normal bone architecture also make it appealing.Objectives: Evaluating the functional results of the use of mini-external fixator for the treatment of compound fractures of phalangeal bones of the hand.Method: Our study consists of 15 patients, 12 w

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 17 2025
Journal Name
Baghdad Science Journal
Utilizing an Atomic Force Microscopy with Continuous Flow Injection Analysis using NAG-4(sources)x3 with Three Solar Cells (NAG-4SX3-3D) Analyzer for Studying the Surface Morphology of the Precipitate of the Cyproheptadine-HCl and Loratadine
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Investigations on the Impact of Using Elliptic Groynes on the Flow in Open Channels
...Show More Authors

This paper presents a numerical simulation of the flow around elliptic groynes by using CFD ‎software. The flow was simulated in a flume with 4m long, 0.4m wide, ‎and 0.175m ‎high ‎‎with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow ‎‎inlet with a ‎constant the Groyne height of 10cm and a 1cm thickness, and the ‎width of Groynes equals ‎7cm‎. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of ‎0.0057‎m3/sec. The CFD ‎model showed a good ability to simulate the flow ‎around ‎Groynes with ‎ good accuracy. The results of ‎CFD software showed that when using double elliptic Groy

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 01 2002
Journal Name
University Of Baghdad
theoretical study of the drift velocity of electron in sf6-n2
...Show More Authors

Publication Date
Sun Jan 01 2023
Journal Name
International Journal Of Research In Social Sciences And Humanities
The Effect of Default Risk on Cash Flow Profitability Indicators: Analytical Research for a Sample of Iraqi Private Banks
...Show More Authors

Focusing on the negative role of default risk on banks, as it is one of the most important risks facing banks, which are difficult to determine accurately, and its reflection on the indicators of profitability of cash flows. The increasing competition between banks led to an increase in the credit facilities granted by banks, and was accompanied by an increase in exposure to the risks of default, which led to an impact on the level of performance of banks in terms of achieving the required return according to the levels of high competition. Therefore, the problem of this study focused on the extent to which the risk indicators of default affect the profitability indicators of the cash flows of the banks research sample in the profit

... Show More
View Publication Preview PDF
Crossref