Preferred Language
Articles
/
HRYKU4cBVTCNdQwC2kV5
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Modeling of Plasma Affected Thermal Profile in Solids During Laser Materials Processing
...Show More Authors

A new scheme of plasma-mediated thermal coupling has been implemented which yields the temporal distributions of the thermal flux which reaches the metal surface, from which the spatial and temporal temperature profiles can be calculated. The model has shown that the temperature of evaporating surface is determined by the balance between the absorbed power and the rate of energy loss due to evaporation. When the laser power intensity range is 107 to108 W/cm2 the temperature of vapor could increase beyond the critical temperature of plasma ignition, i.e. plasma will be ignited above the metal surface. The plasma density has been analyzed at different values of vapor temperature and pressure using Boltzmann’s code for calculation of elec

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 11 2019
Journal Name
Aip Conference Proceedings
Estimation of shock wave position in plasma plume using Sedov-Taylor model
...Show More Authors

In this work, radius of shock wave of plasma plume (R) and speed of plasma (U) have been calculated theoretically using Matlab program.

Publication Date
Fri Mar 01 2013
Journal Name
International Journal Of Recent Research And Review
Influence of Discharge Pressure on the Plasma Parameter in a Planar Dc-Sputtering Discharge of Argon
...Show More Authors

Abstract- Plasma parameters in a planar dc-sputtering discharge in argon were measured by cylindrical electrostatic probe (Langmuir probe).Electron density, electron temperature, floating potential, and space potential were monitored as a function of working discharge pressure. Electrostatic probe and supporting circuit were described and used to plot the current – voltage characteristics. Plasma properties were inferred from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values are in the range of (10-16 -10-17) m-3 and (2.93 – 5.3) eV for the electron density and the electron temperature respectively.

Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
International Journal Of Science And Research (ijsr)
Salivary TNF-α andAlkaline Phosphatase in Relation to Gingival Health Condition According to Nutritional Status among a Group of School Children
...Show More Authors

View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Kuwait Journal Of Science
The effect of magnetic field variations on the spectral properties of tornado plasma
...Show More Authors

At atmospheric pressure and at a frequency of 9.1 kHz, a constructed magnetically stabilized tornado gliding arc discharge (MSGAD) system was utilized in this study to generate a non-thermal plasma with an alternating voltage source from 2,4,6,8 to 10 kV. Argon gas was used to generate the arc plasma with an adjustable flow rate using a flow meter regulator to stabilize the gas flow rate to 2 L/min. A gliding plasma discharge is achieved by a magnetic field for the purpose of a planned investigation. The influence of the magnetically stabilized tornado gliding arc discharge parameters such as magnetic field and applied voltage on microscopic tornado plasma parameters was studied. The electron temperature1was measured using a Boltzmann plot

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jun 20 2030
Journal Name
Al-kindy College Medical Journal
The Functional Results of Surgical Percutaneous Joystick Reduction Therapy for Isolated Severely Angulated Radial Neck Fracture in Children
...Show More Authors

Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 24 2020
Journal Name
Al-kindy College Medical Journal
The Functional Results of Surgical Percutaneous Joystick Reduction Therapy for Isolated Severely Angulated Radial Neck Fracture in Children
...Show More Authors

Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 10 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Adherence to American Society of Health-System Pharmacists Surgical Antibiotic Prophylaxis Guideline in Medical City Teaching Hospitals/Baghdad
...Show More Authors

Surgical site infections are the second most common type of adverse events occurring in hospitalized patients. Surgical antibiotic prophylaxis refers to the use of preoperative and postoperative antibiotics to decrease the incidence of postoperative wound infections. The objective of this study was to evaluate the antibiotic administration pattern for surgical antibiotic prophylaxis and the adherence to American Society of Health-System Pharmacists surgical antibiotic prophylaxis guideline in Medical City Teaching Hospitals/Baghdad. The medical records of one hundred patients who underwent elective surgical procedures were reviewed. Adherence to the recommendations of American society of health‑system pharmacists guideline was ass

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Arpn Journal Of Engineering And Applied Sciences
Achieving a theoretical approximation characterize the stopping power of heavy ion in D-T plasma
...Show More Authors

The dependence of the energy losses or the stopping power for the ion contribution in D- T hot plasma fuels upon the corresponding energies and the related penetrating factorare arrive by using by a theoretical approximation models. In this work we reach a compatible agreement between our results and the corresponding experimental results.

View Publication Preview PDF
Scopus
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Stomatology
The effectiveness of limited flap design in surgical removal of fully impacted lower third molars: a comparative clinical study
...Show More Authors

View Publication
Crossref (3)
Crossref