Two‐dimensional buoyancy‐induced flow and heat transfer inside a square enclosure partially occupied by copper metallic foam subjected to a symmetric side cooling and constant heat flux bottom heating was tested numerically. Finite Element Method was employed to solve the governing partial differential equations of the flow field and the Local Thermal Equilibrium model was used for the energy equation. The system boundaries were defined as lower heated wall by constant heat flux, cooled lateral walls, and insulated top wall. The three parameters elected to conduct the study are heater length (7 ≤
Current design codes and specifications allow for part of the bonded flexure tension reinforcement to be distributed over an effective flange width when the T-beams' flanges are in tension. This study presents an experimental and numerical investigation on the reinforced concrete flanged section's flexural behavior when reinforcement in the tension flange is laterally distributed. To achieve the goals of the study, numerical analysis using the finite element method was conducted on discretized flanged beam models validated via experimentally tested T-beam specimen. Parametric study was performed to investigate the effect of different parameters on the T-beams flexural behavior. The study revealed that a significant reduction in the
... Show MoreExperimental and theoretical studies were carried out to investigate the depressurization induced by steam jet using subsonic steam ejector with flat-plate solar thermal collector. Saline water flash evaporation could be realized by such depressurization in water desalination systems. The most critical component in such systems is the steam ejector nozzle where the Mach number within the ejector is highly influenced by its geometry. The main objective of the research is to evaluate the effect of different operating parameters on evaporation performance which can be specified by two factors; first is the subsonic ejector efficiency governed by the steam entrainment ratio, and second is the percentage gain of distilled water productivity. Tha
... Show MoreBackground: periodontitis is a chronic inflammatory disease causing destruction of the tooth supporting structures, initiated by dental plaque and modified by environmental and genetic risk factors. Cyclooxygenase-2 (COX-2) enzyme is responsible for the production of prostaglandin E2, an important mediator in the chronic periodontitis (CP) pathogenesis. Polymorphisms in COX-2 gene have linked to CP in different populations. Aim: To study the association between Cyclooxygenase-2 single nucleotide polymorphism rs689466 (-1195A/G SNP) and chronic periodontitis in a sample of Iraqi population. Methods: One hundred Iraqi subjects divided into two groups: case group consisted of 70 CP patient (35 males and 35 females) with age range 30-55 year
... Show MoreThe purpose of this research highlight the achievement of the effectiveness of small and medium enterprises dimensions and conformable to analyze the relationship between business strategies and human resources management strategies , and launched search of a dilemma thought provoking fundamental questions revolve around the search is the lack of appropriate strategies in these enterprises to help them continuity and permanence in business and markets , as these enterprises lack the human resources management strategies appropriate , as well as business strategies that make them withstand the changes in the market environment is changing and volatile . It was to
... Show MoreThis study conducted an analytical investigation on the behavior of concrete beams with openings reinforced by glass-fiber-reinforced polymer (GFRP) bars. In this study, five proposed beams reinforced by GFRP bars as flexural and shear reinforcement with openings were numerically examined. The variables were the opening orientation (vertical and horizontal) and the number of openings. These openings were located within the flexural zone of the proposed beams. The result shows that the vertical openings had a significant effect over the horizontal openings on reducing the ultimate load and increasing the mid-span deflection compared with the control beam. Moreover, the results showed t
This study conducted an analytical investigation on the behavior of concrete beams with openings reinforced by glass-fiber-reinforced polymer (GFRP) bars. In this study, five proposed beams reinforced by GFRP bars as flexural and shear reinforcement with openings were numerically examined. The variables were the opening orientation (vertical and horizontal) and the number of openings. These openings were located within the flexural zone of the proposed beams. The result shows that the vertical openings had a significant effect over the horizontal openings on reducing the ultimate load and increasing the mid-span deflection compared with the control beam. Moreover, the results showed t
This study deals with free convection heat transfer for the outer surface of two
cylinders of the shape of (Triangular & Rectangular fined cylinders with 8-fins),
putted into two different spaces; small one with dimension of (Length=1.2m,
height=1m, width=0.9m) and large one with dimension of (Length=3.6m, height =3m,
width=2.7m). The experimental work was conducted with air as a heat transport
medium. These cylinders were fixed at different slope angles (0o, 30o, 60o and 90o)
.The heat fluxes were (279, 1012, 1958, 3005, 4419) W/m2, where heat transferred by
convection and radiation. In large space, the results show that the heat transfer from
the triangular finned cylinder is maximum at a slope angle equals
The cost-effective carbon cross-linked Y zeolite nanocrystals composite (NYC) was prepared using an eco-friendly substrate prepared from bio-waste and organic adhesive at intermediate conditions. The green synthesis method dependent in this study assures using chemically harmless compounds to ensure homogeneous distribution of zeolite over porous carbon. The greenly prepared cross-linked composite was extensively characterized using Fourier transform infrared, nitrogen adsorption/desorption, Field emission scanning electron microscope, Dispersive analysis by X-ray, Thermogravimetric analysis, and X-ray diffraction. NYC had a surface area of 176.44 m2/g, and a pore volume of 0.0573 cm3/g. NYC had a multi-function nature, sustained at a long-
... Show MoreBackground: The presence of anatomic variations within the maxillary sinus such as septa has been reported to increase the risk of sinus membrane perforation during sinus elevation procedure for implant placement. This study aimed to measure the septal heights and correlate it with different types of septa. Material and methods: Thirty patients (15 males and 15 females) with partially edentulous maxillae and mean age (35) years were enrolled in this study. Sixty sinuses scanned with Spiral multislice Computed Tompgraphy, septal height measured after evaluation of septal type whether it was primary or secondary. Results: The results showed that 72.5 % of the septa detected were primary and this is statistically significant when compared w
... Show MoreRudimentary non-communicating functional uterine horn with unicornuate uterus, originating from anomalous embryological development of one Mullerian duct, is prone to different complications either at the gynecological or obstetrical level such as chronic pelvic pain, hematometra, subfertility and decreased quality of life. This unique case report presents a 14-year-old female with a history of severe chronic pelvic pain. She was diagnosed with Familial Mediterranean Fever (FMF) and had an appendectomy for suspected appendicitis within the symptoms’ interval. Ultrasound showed a right 5*6 cm right complex cystic mass assuming ovarian in place. She underwent a suspected endometrioma cystectomy operation and was diagnosed with left unico
... Show More