This paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the reference specimen by 156.2% for a composite beam with GFRP with shear connectors, 148.6% for composite beams with GFRP without connectors, and 96% for the composite beam with a steel I-section.
To decrease the impact on the environment of building waste, the recycled aggregate may be used in various sustainable engineering applications, such as roller compacted concrete pavement (RCCP). This research examined how using recycled aggregate as a partial replacement for natural aggregate as coarse or fine affected the mechanical properties of roller-compacted concrete pavement. The recycled aggregate was crushed and sieved to coarse and fine aggregate before being used in the roller-compacted concrete pavement. Compressive strength, splitting tensile strength, and flexural strength were all evaluated after the samples were prepared at 28 and 90 days of curing. According to the study's findings, the partial replacem
... Show MoreBackground: One of the major problems in endodontics is micro-leakage of root canal fillings which might contribute to the failure of endodontic treatment. To avoid this problem, a variety of sealers have been tested. The objective of this, in vitro, study was to evaluate the shear bond strength of four resin based sealers (AH plus, silver free AH26, RealSeal SE and Perma Evolution permanent root canal filling material) to dentin. Materials and Methods: Forty non-carious extracted lower premolars were used. The 2mm of the occlusal surfaces of teeth were sectioned, to expose the dentin surface. The exposed dentin surfaces of teeth were washed with 5ml of 2.5% NaOCl solution followed by 5ml of 17 % EDTA then rinsed by deionized water to remov
... Show More
Abstract:
We can notice cluster data in social, health and behavioral sciences, so this type of data have a link between its observations and we can express these clusters through the relationship between measurements on units within the same group.
In this research, I estimate the reliability function of cluster function by using the seemingly unrelate
... Show MoreMost of the big companies and especially the intillictual ones become a ware of an important fact, and That is, The intillictual capital in new global economy, is a new source for Them & This Valuable source exceed in importance. The other company's sources.
The Traditional disclouser systemes are unable to supply the decisions makers with the Fundimental information require to handel the on going operations which are based on Knowledge and intangible source. But the measuring of this source and the disclose for it in the financial Statements will lead to gain features Statements which will benefit all the parties and lead to make the value of the company great.
And as a resul
... Show MoreThe research aims at introducing the principles of six sigma and if it had any effect of the dimensions of six sigma to improve the performance of the dentists and the availability of an appropriate environment in the center Specialist respondent to the application of six sigma principles and how to adopt Specialized Center under the dimensions of the six sigma and if there informed enough with the management methodology six sigma, and if you can adopt six sigma as one of the entrances to reduce medical errors. So Search creating six sigma five dimensions and are (the commitment and support of senior management, the focus on the patient, continuous improvement, training and civil, and infrastructure) as a variable int
... Show MoreThe inhibitive action of polyvinyl alcohol –sodium nitrite (PVASN) composite on the corrosion of mild steel in simulated cooling water (SCW) has been investigated by weight loss and potentiodynamic polarization. The effect of composite concentration (PVA/SN) , pH, and exposure time on corrosion rate of mild steel were verified using 2 levels factorial design and surface response analysis through weight loss approach, while the electrochemical measurements were used to study the behavior of mild steel in (SCW) with pH between 6 and 8 and in absence and presence of (PVA) in solution containing different concentration of NaNO2. It was verified that all three main variables studied were statistically significant while their interaction is
... Show MoreIn the coming decade, a substantial rise in energy consumption within the buildings sector is predicted to lead to a 30% increase in greenhouse gas emissions. The choice of materials for building envelopes significantly influences the overall energy demand of HVAC systems, which contribute significantly to electricity usage. To enhance compatibility between grey clay and straw, a suggested approach involves using a composite material comprising rice water and grey clay, enriched with a high proportion of rice straw and soaked in rice water. This environmentally friendly technique yields a green construction material capable of reducing energy consumption in HVAC systems by up to 35.6% over a 24-h period. The potential energy savings of this
... Show MoreIn this research the relation between skin resistances and standard penetration test of over consolidated
clay soils has been studied. The research includes doing boreholes at Babil governorate in Iraq to get
undisturbed samples and standard penetration test. Determination skin friction from direct shear test between
smooth concrete and soil was explored in laboratory for design purposes and correlated with standard
penetration test values. In many foundation design problems, the shear strength between soil and
foundation materials were estimated or correlated without any direct methods for measurement.
Twelve strain controlled direct shear tests were performed simulate the shear strength interaction
between smooth c