Background: clinically significant macular edema (CSME) is the commonest cause of visual loss in patients with diabetes mellitus and laser focal photocoagulation is the golden standard for treating it. Patients and Methods: A frequency doubled Nd: YAG laser was used to treat all eyes included in this study with diabetic maculopathy. Thirty eyes of three insulin dependent and twenty six non insulin dependent diabetic Iraqi patients were included. The study involved twenty six males, three females and followed for one year. Their ages were ranging between 36- 59 years, all of them from patients attending ophthalmic out-patient department in the medical city in the period between January 2005 and June 2006. Eyes divided in to two groups (fifteen eyes in each group) and the disease severity was taken into account. The first group treated with 0.1 second and second group with 0.2 second pulse duration. Results: In group (1) improvement of V.A occurred in 19.99% (Statistically significant) and 60% (Statistically significant) in group (2). There was stabilization 80% (Statistically insignificant) in group (1) and 33.33% Stabilization (Statistically significant) in group (2), while worsening only in group (2) 6.67% (Statistically insignificant). Conclusion: The frequency doubled Nd:YAG laser is effective in controlling diabetic macular oedema when applied in focal treatment. The setting of 100µm 0.2sec., pulse exposure time show more improvement in V.A. than 100µm 0.1sec
In this work Polyynes was synthesized by pulse laser ablation of graphite target in ethanol solution. UV-Visible Spectrophotometer, Fourier Transform Infrared Spectroscopy (FTIR) and Transmission electron microscopy (TEM) were used to study the optical absorption, chemical bonding, particle size and the morphology. UV absorption peaks coincide with the electronic transitions corresponding to linear hydrogen – capped polyyne (Cn+1H2), the absorption peaks intensity increased when the polyynes were produced at different laser energies and the formation rats of polyynes increased with the increasing of laser pulse number. The FTIR absorption peak at 2368.4 cm-1, 1640.0 cm-1 and 1276.
... Show MoreThis study was conducted to determine the relationship between two most common diseases in Iraqis patients , which are Diabetic mellitus (DM) and Rheumatoid Arthritis (RA); seeking rheumatoid factor in hyperglycemic sera. The results revealed that ; 62.5% of hyperglycemic (HG) patients had positive rheumatoid factor (RF) . No difference in number between both gender of HG patients (20 males and 20 females ) , RF reaction was nearly similar in males and females of HG patients ( 12 &13 respectively ) . Only 40% out of patient controls had positive RF . None of the apparently healthy subjects had positive RF .
Diabetes Mellitus is a group of metabolic diseases characterized by increasing of glucose level in plasma compared with normal value (hyperglycemia). This disease also causes elevation of lipid profile levels except HDL (High density lipoproteins) which increased relatively. The effects of the polyphenolic mixture (catechins, epicatechins, procyanidin B1, procyanidin B2 and procyanidin C1) on total cholesterol (TC), triacylglycerol (TG), high density lipoprotein (HDL) and low density lipoprotein (LDL) were studied in (30) streptozotocin-induced diabetic mice with (20-25)gm weight. Mice were given (30 mg/mL) of Polyphenolic Cocoa beans Extracts (CE) once daily for (7) days before Streptozotocin STZ injection and for (21 day) there after. A
... Show MoreThe rapid spread of the COVID-19 coronavirus in 2019 infected many people, primarily affecting the respiratory system. Both COVID-19 and type 2 diabetes have been associated with numerous risks that have become life-threatening. The study studied the link between galectin levels and some clinical characteristics in Iraqis with type 2 diabetes and COVID-19 against those without diabetes. The study included 120 patients and healthy men. Three groups were formed for this study depending on the initial mutant cell line: 80 samples of individuals with type 2 diabetes, aged 40–60 years, with and without COVID-19, were included in each of the first and second groups. The control group consisted of 40 research participants who were matched for ag
... Show MoreThis study deals with thirty non-insulin dependent diabetes mellitus patients suffering from diabetic nephropathy in addition to twenty five healthy control.Some biochemical parameters were determined in the serum of all subjects enrolled in the study.These parameters are serum glucose,serum urea,serum creatinine,total serum protein and serum albumin.The aim of the present study was to estimate these parameters in diabetic nephropathy patients. The results of the present study revealed a significant increase in glucose,urea and creatinine in patients as compared to controls . Also a significant decrease was found in total serum protein, serum albumin and albumin to globulin ratio (A/G) in patients compared to controls,whi
... Show More
Abstract: Narrow laser pulses have been essential sources in optical communication system. High data rate optical communication network system demands compressed laser source with unique optical property. In this work using pulsed duration (9) ns, peak power 1.2297mW, full width half maximum (FWHM) 286 pm, and wavelength center 1546.7 nm as compression laser source. Mach Zehnder interferometer (MZI) is built by considering two ways. First, polarization maintaining fiber (PMF) with 10 cm length is used to connect between laser source and fiber brag grating analysis (FBGA). Second, Nested Mach Zehnder interferometer (NMZI) was designed by using three PMFs with 10 cm length. These three Fibers are splicing to sing
... Show MoreThis study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University. The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged
... Show MoreWith the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil’s mutual displacement and coupling coef
... Show More