Background: clinically significant macular edema (CSME) is the commonest cause of visual loss in patients with diabetes mellitus and laser focal photocoagulation is the golden standard for treating it. Patients and Methods: A frequency doubled Nd: YAG laser was used to treat all eyes included in this study with diabetic maculopathy. Thirty eyes of three insulin dependent and twenty six non insulin dependent diabetic Iraqi patients were included. The study involved twenty six males, three females and followed for one year. Their ages were ranging between 36- 59 years, all of them from patients attending ophthalmic out-patient department in the medical city in the period between January 2005 and June 2006. Eyes divided in to two groups (fifteen eyes in each group) and the disease severity was taken into account. The first group treated with 0.1 second and second group with 0.2 second pulse duration. Results: In group (1) improvement of V.A occurred in 19.99% (Statistically significant) and 60% (Statistically significant) in group (2). There was stabilization 80% (Statistically insignificant) in group (1) and 33.33% Stabilization (Statistically significant) in group (2), while worsening only in group (2) 6.67% (Statistically insignificant). Conclusion: The frequency doubled Nd:YAG laser is effective in controlling diabetic macular oedema when applied in focal treatment. The setting of 100µm 0.2sec., pulse exposure time show more improvement in V.A. than 100µm 0.1sec
Background: Bimaxillary protrusion is considered as one of the most important causes to seek the orthodontic treatment to get better esthetics. This study aimed to test the effect of orthodontic treatment in improvement the facial esthetics. Materials and Methods: Ten Iraqi Arab females having bimaxillary protrusion based on Class I malocclusions treated with fixed orthodontic appliance and extraction of the maxillary and mandibular 1st permanent premolars. Pre and post-treatment facial profile photographs were taken for each patients and the effect of treatment was tested in comparison with the pre-treatment photographs by using seven angular measurements. Results: After treatment, the upper and lower lip projections were decreased signifi
... Show MoreIn this study, successive electrocoagulation (EC) and electro-oxidation (EO) processes were used to minimize some of the major pollutants in real wastewater, such as organics (detected by chemical oxygen demand (COD)), and turbidity. The wastewater utilized in the present study was collected from the Midland Refinery Company in Baghdad-Iraq. The performance of the successive batch EC-EO processes was studied by utilizing Graphite and Aluminum (Al) as monopolar anode electrodes and stainless steel (st.st.) as the cathode. The Taguchi experimental design approach was used to attain the best experimental conditions for COD reduction as a major response. Starting from chemical oxygen demand COD of (600 ppm), the effects of current densi
... Show MoreThis study was undertaken to diagnose routine settling problems within a third-party oil and gas companies’ Mono-Ethylene Glycol (MEG) regeneration system. Two primary issues were identified including; a) low particle size (<40 μm) resulting in poor settlement within high viscosity MEG solution and b) exposure to hydrocarbon condensate causing modification of particle surface properties through oil-wetting of the particle surface. Analysis of oil-wetted quartz and iron carbonate (FeCO₃) settlement behavior found a greater tendency to remain suspended in the solution and be removed in the rich MEG effluent stream or to strongly float and accumulate at the liquid-vapor interface in comparison to naturally water-wetted particles. As su
... Show MoreIn this study, successive electrocoagulation (EC) and electro-oxidation (EO) processes were used to minimize some of the major pollutants in real wastewater, such as organics (detected by chemical oxygen demand (COD)), and turbidity. The wastewater utilized in the present study was collected from the Midland Refinery Company in Baghdad-Iraq. The performance of the successive batch EC-EO processes was studied by utilizing Graphite and Aluminum (Al) as monopolar anode electrodes and stainless steel (st.st.) as the cathode. The Taguchi experimental design approach was used to attain the best experimental conditions for COD reduction as a major response. Starting from chemical oxygen demand COD of (600 ppm), the effects of current density (C
... Show MoreBackground: Oral health represents an important base for human well-being; the heath of the body begins from oral cavity. Great deal has been applied to increase knowledge in the field of oral health in order to develop appropriate preventive program. This study was conducted in order to estimate the percentage and severity of dental caries and gingivitis among children attending Preventive Department in Collage of Dentistry, University of Baghdad and to determine dental treatment need for those patients, further more to study the relation of these variables with dental knowledge. Materials and Methods: The study group consists of 163 children with an age ranged from 6 to 14 years, who attended the preventive clinic for the first time to be
... Show MoreKE Sharquie, AA Al-Nuaimy, WJ Kadhum, Saudi medical journal, 2006 - Cited by 3
The present study analyzes the effect of couple stress fluid (CSF) with the activity of connected inclined magnetic field (IMF) of a non-uniform channel (NUC) through a porous medium (PM), taking into account the sliding speed effect on channel walls and the effect of nonlinear particle size, applying long wavelength and low Reynolds count estimates. The mathematical expressions of axial velocity, stream function, mechanical effect and increase in pressure have been analytically determined. The effect of the physical parameter is included in the present model in the computational results. The results of this algorithm have been presented in chart form by applying the mathematical program.
Abstract Background: Articular cartilage lesions in the knee joint are frequently seen,its treatment represents a challenge for orthopedic surgeons especially in young age patients and if left untreated,then they can progress to advanced osteoarthritis that may affect the functional status of the patients.Many treatment modalities had developed for these lesions, in the current study arthroscopic micro fracture plus intra articular whole bone marrow(WBM) injection was used as modality of treating these lesions. Objectives: to assess the effectiveness of arthroscopic micro fracture plus WBM intra articular injection as a treatment modality for knee articular cartilage lesions. Patients and Methods : a prospective experimental study was perf
... Show MoreLaser shock peening (LSP) is deemed as a deep-rooted technology for stimulating compressive residual stresses below the surface of metallic elements. As a result, fatigue lifespan is improved, and the substance properties become further resistant to wear and corrosion. The LSP provides more unfailing surface treatment and a potential decrease in microstructural damage. Laser shock peening is a well-organized method measured up to the mechanical shoot peening. This kind of surface handling can be fulfilled via an intense laser pulse focused on a substantial surface in extremely shorter intervals. In this work, Hydrofluoric Acid (HF) and pure water as a coating layer were utilized as a new technique to improve the properti
... Show MorePhotobiomodulation (PBM) is a form of the use of visible red and Near-infrared (NIR) light at low power, where a laser light photon is absorbed at the electronic level, without heat production. PBM can be applied in wide range of treatment to help the wound, inflammation, edema, and pain reduction. However, there is a lack of scientific documentation regarding its actual effects. Objectives: This study assesses the impact of PBM on the release of M1-related cytokine in monocyte cells with particular emphasis on interleukin-1β (IL-1β) and Tumour Necrosis Factor α (TNF-α). Methods: Tamm-Horsfall Protein 1 (THP-1) macrophages M1 cells have been exposed to the light from the diode laser of 850nmat different doses (0, 0.6, 1.2 and 3.
... Show More