One of the most important processes to obtain gasoline with high octane numbers is isomerization. In this paper, Pt/TiO2 was prepared successfully by using the sol–gel method by hydrolysis of titanium tetraisopropoxide as a titania source with ethanol and then platinum was loaded on the synthesized catalyst; the result shows that the sample prepared has a good crystallinity with a surface area of about 85 m2 /g and a pore volume of 0.1938 cm3 /g, while XRD shows that the prepared sample was anatase phase. The efect of both temperature and liquid hourly space velocity of the prepared catalyst was achieved by hydroisomerization of n-hexane in a fxed bed reactor with a temperature of 200–275 °C and LHSV 0.5–2h−1. The results show that the conversion of n-hexane was increased with increasing temperature and decreasing LHSV; the maximum conversion achieved at temperature 275 °C and 0.5 h−1 was 63.54% at atmospheric pressure.
Aniline and its derivatives are common contaminants in various wastewaters and represent a serious worry for societies health and a challenge to ecologists due to their dangers effects on to the human health.
ZSM-5 zeolite was prepared from locally available materials (kaolin and rice husk) for adsorption of aniline from synthetic wastewater. Characterization of the prepared zsm-5, kinetics and thermodynamic of the adsorption process were investigated.
The characterization results of the prepared zsm-5 zeolite showed that the surface area was 270.1 m2/g and pore volume 0.21828 cm3/g. The silica to alumina ratio (Si/Al) was 166. 47 and the sodium content was 11 wt. %. The atomic force microscope (AFM)
... Show MoreThe present work reports a direct experimental comparison of the catalytic hydrodesulfurization of
thiophene over Co-Mo/Al2O3 in fixed- and fluidized-bed reactors under the same conditions. An
experimental pilot plant scale was constructed in the laboratories of chemical engineering department,
Baghdad University; fixed-bed unit (2.54 cm diameter, and 60cm length) and fluidized-bed unit (diameter of 2.54 cm and 40 cm long with a separation zone of 30 cm long and 12.7 cm diameter). The affecting
variables studied in the two systems were reaction temperature of (308 – 460) oC, Liquid hourly space
velocity of (2 – 5) hr-1, and catalyst particle size of (0.075-0.5) mm. It was found in both operations that the
conversion
KE Sharquie, AA Noaimi, ER Shwail, J Clin Exp Dermatol Res, 2012 - Cited by 41
Complexes of Au(III) ,Pd (II) , Pt (IV ) and Rh(III) with S – propynyle -2- thiobenzimidazole (BENZA) have been prepared and characterized by IR and UV- Visible spectral methods in addition to magnetic and conductivity measurements and micro – elemental analysis (CHN).The probable structures of the new complexes have been suggested.
Increasing demands on producing environmentally friendly products are becoming a driving force for designing highly active catalysts. Thus, surfaces that efficiently catalyse the nitrogen reduction reactions are greatly sought in moderating air-pollutant emissions. This contribution aims to computationally investigate the hydrodenitrogenation (HDN) networks of pyridine over the γ-Mo2N(111) surface using a density functional theory (DFT) approach. Various adsorption configurations have been considered for the molecularly adsorbed pyridine. Findings indicate that pyridine can be adsorbed via side-on and end-on modes in six geometries in which one adsorption site is revealed to have the lowest adsorption energy (–45.3 kcal/mol). Over a nitr
... Show MoreThe aim: In this study, we present and evaluate the vest-over-pants technique as a simple way to correct urethrocutaneous fistulas after hypospadias. Materials and methods: Between October 2018 and June 2020, twenty male patients aged 5 to 20 years came to us with post hypospadias repair fistula, these patients underwent vest-over-pant repair of their fistula. The size of fistula was ranging between 2.5-5 mm. The distribution of fistula was coronal (3 patients), distal penile (9 patients), midshaft (2 patients) and proximal penile (6 patients). In 14 patients there were single fistula and 6 patients had more than one fistula. Eleven of patients were exposed to a previous failed fistula repair procedure. Results: Six months after the operati
... Show MoreIn this study; a three-dimensional model was created to simulate groundwater in Al-Haydariyah area of the governorate of Al-Najaf. A solid model was created to utilize the cross sections of 25 boreholes in the research region, and it was made out of two layers: sand and clay. The steady-state calibration was employed in six observation wells to calibrate the model and establish the hydraulic conductivity, which was 17.49 m/d for sand and 1.042 m/d for clay, with a recharge rate of 0.00007 m/day. The wells in the research region were reallocated with a distance of 1500 m between each well, resulting in 140 wells evenly distributed throughout the study area and with a discharge of 5 l/s, and the scenarios were run for 1000
... Show MoreIn this paper the queuing system (M/Er/1/N) has been considered in equilibrium. The method of stages introduced by Erlang has been used. The system of equations which governs the equilibrium probabilities of various stages has been given. For general N the probability of j stages of service are left in the system, has been introduced. And the probability for the empty system has been calculated in the explicit form.