Preferred Language
Articles
/
GBcKiI4BVTCNdQwCc0wn
Experimental study on thermo‐hydraulic performance of metal foam twisted tape in a double pipe heat exchanger
...Show More Authors
Abstract<p>A recent study compared experimentally the hydraulic and thermal activity of twisted tape inserts for two types, metal foam twisted tape (MFTT) and traditional twisted tape (TTT), in a double pipe heat exchanger. The investigation goal of the innovatively designed MFTT is to enhance the heat transfer process, which provides a higher thermal enhancement factor over those of TTT under the same conditions. Heat transfer activity in terms of Nusselt number (<italic>Nu</italic>) and Nusselt number ratio (<italic>Nu</italic>/<italic>Nu</italic><sub>o</sub>) as the heat exchanger equipped with the proposed MFTT and TTT inserts with various tape‐twist ratios (<italic>y</italic>/<italic>W</italic> = 3.6, 5.2, and 6.8) are considered over various values of Reynolds numbers (16,300 < <italic>Re</italic> < 32,500). The results reveal an improvement in heat transfer rate with both MFTT and TTT and this improvement is proportional inversely to the twisted ratio, but the MFTT showed the highest value of heat transfer compared to TTT and clear tube. Also, the <italic>Nu</italic> of MFTT augments averaged about 175%–230% compared to the TTT depending on the twist ratio and about 275% and 500% over that of the clear tube. At a twist ratio of 3.6, the heat transfer coefficient is recorded at 37% and 45% for MFTT and TTT models, respectively, with an increase in Re. However, friction factor (<italic>f</italic>) increases about 35% for MFTT with decreasing in twist ratio (from 6.8 to 3.6). The effectiveness of the proposed MFTT in the range of <italic>Re</italic> used is found to be about 12%, 15%, and 18% higher than those induced by TTT at twisted tape ratio (<italic>y</italic>/<italic>w</italic> = 3.6, 5.2, and 6.8), respectively.</p>
Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jun 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study of Thermophysical Properties of TiO2 Nanofluid
...Show More Authors

Titanium-dioxide (TiO2) nanoparticles suspended in water, and ethanol based fluids have been prepared using one step method and characterized by scanning electron microscopy (SEM), and UV–visible spectrophotometer. The TiO2 nanoparticles were added to base fluids with different volume concentrations from 0.1% to1.5% by dispersing the synthesized nanoparticles in deionized water and ethanol solutions. The effective thermal conductivity, viscosity and pH of prepared nanofluids at different temperatures from 15 to 30 oC were carried out and investigated. It was observed that the thermal conductivity, pH, and viscosity of nanofluids increases with the increase in TiO2 nanoparticle volume fraction

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 06 2001
Journal Name
مجلة العلوم الاقتصادية والادارية
Double cross-over and cross-over with extra period designs -comparative study-
...Show More Authors

The goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.

Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Theoretical Study of the Energy Flow of a Two Stages Four Generators Adsorption Chiller
...Show More Authors

This work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C.  As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Nov 04 2012
Journal Name
Journal Of The College Of Basic Education
Double Stage Shrinkage Estimator in Pareto Distribution
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Vibration analysis of angle-ply laminates composite plate under thermo-mechanical effect
...Show More Authors

The paper presents mainly the dynamic response of an angle ply composite laminated plates subjected to thermo-mechanical loading. The response are analyzed by analytically using Newmark direct integration method with Navier solution, numerically by ANSYS. The experimental investigation is to fabricate the laminates and to find mechanical and thermal properties of glass-polyester such as longitudinal, transverse young modulus, shear modulus, longitudinal and transverse thermal expansion. Present of temperature could increase dynamic response of plate also depending on lamination angle, type of mechanical load and the value of temperature.

 

View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The role of TD-ABC approach in decreasing of cost per unit: Applied study in the General company of Hydraulic Industries \ Plastic Factory
...Show More Authors

The aim of the research is to use this technique and to determine the effect of this method in reduce cost per unit of the company. The traditional method used in the company the research sample to determine the indirect costs, the definition of the concepts and characteristics of the method of cost-based activity and the cost method based on time-driven activity and justifications applied to companies.   In order to achieve the research objectives, the main hypotheses were formulated. That was represented: (The applied of (TDABC) Time driven activity based costing method in reducing indirect costs, leads reduce cost per unit than the use of the traditional method of allocating indirect costs in the research sample company).&nb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
The Role of the values of accounting culture in maximizing financial performance - A field study in a sample of Iraqi banks
...Show More Authors

The influence of culture on accounting systems and practices, including financial reports and accounting information through the values ​​identified by Gray and derived from social-cultural values, and the four accounting values ​​were derived from generally accepted accounting principles represented by (Conservatism, Uniformity, Secrecy, and Professionalism). Important and significant in maximizing financial performance, and measuring the extent of the role of these values ​​in improving financial performance through attention to the values ​​of accounting culture, this research

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 10 2023
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Detection of Multiple Sclerosis Lesions in Supra- and Infra-Tentorial Anatomical Regions by Double Inversion Recovery, Flair, and T2 MRI Sequences: A Comparative Study in Iraqi Patients
...Show More Authors

Background: In young adults, multiple sclerosis is a prevalent chronic inflammatory demyelinating condition. It is characterized by white matter affection, but many individuals also have significant gray matter involvement. A double-inversion recovery pulse (DIR) pattern was recently proposed to improve the visibility of multiple sclerosis lesions. Objective: To find out how well a DIR sequence, FLAIR, and T2-weighted pulse sequences can find MS lesions in the supratentorial and infratentorial regions. Methods: A total of 37 patients with established diagnoses of multiple sclerosis were included in this cross-sectional study. Brain MRI was done using double inversion recovery, T2, and FLAIR sequences. The number of lesions was count

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Experimental Investigating of Unsupported Excavation Considering Its Effect on a Nearby Axially Loaded Pile
...Show More Authors

An experimental model is used to simulate the loss of soil lateral confinement due to excavation nearby an individual axially loaded pile. The effects of various parameters, such as the horizontal distance of excavation, depth of excavation and pile slenderness ratios are investigated. The experimental analysis results showed the effect of excavation is more remarkable as the horizontal distance of excavation becomes closer to the pile than half pile length. The effect of excavation diminishes gradually as the horizontal distance increases beyond that distance for all the investigated pile slenderness ratios and depths of excavation. The pile head deflection, settlement and bending moments along pile increase with decreasing horizontal d

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Sust Journal Of Engineering And Computer Science (jecs)
Virtual failure influence of Roseires dam on Khartoum city using HEC-RAS Hydraulic simulation modeling
...Show More Authors

Dam break is series phenomenon that can result in fatal consequences and loss of properties. Unfortunately, the observed consequences can only be available after the dam breaks. Therefore, it is important to anticipate what will happen prior to dam break to issue suitable warning and locate the possible risk areas. This study attempts to simulate the case of dam break in Blue Nile at Roseires dam and see its consequences downstream. Roseires dam lies at a distance of 630 km south of Khartoum, Sennar dam lies at about 260 km downstream of Roseires dam. In this study hydraulic model is developed based of Hydraulic Engineering Centre (HEC), River Analysis System (RAS), and HEC- RAS. The HEC-RAS based model is calibrated and validated usi

... Show More