Preferred Language
Articles
/
FXjUIKEBuRolNscLA_j0
Recovery of Cold Impacted Escherichia Coli O157:H7 Bacteria in Ground Beef
...Show More Authors
Abstract<p> <italic>Escherichia coli</italic> in fresh minced meat was injured by cooling at 4 °C. A bacterial population has three different physiology which are uninjured or normal cells, sublethally injured cells (or injured cells ), and lethally injured cells (or dead cells). Cell injury is defined as any damage to the components of cells themselves by any stresses which weaken the ability of cells to survive or multiply. This will increase the sensitivity of cells to any harmful factors. The cells can repair their injury which can be extended 48hour depending on the nature of stress and degree of injury. The purpose of this study was to: supplemented some cultural media and preparation new cultural media to isolated <italic>E.coli</italic> with compounds that supplemented the bacterial growth such as yeast extract, sodium pyruvate, n-propyl gallate, catalase, and Tween. Various concentrations of the compound were tested minced beef meat with mixed it and compared with traditional media. The rest of the compound had variable effects on the recovery of cold stressed cells but they weren’t as efficient as needed. It is, therefore recommended that 0.5% of both catalase and tween 80 be used to supplement tryptic soy agar (TSA) in the repair detection procedure.</p>
Scopus Crossref
View Publication
Publication Date
Wed Dec 01 2021
Journal Name
Iraqi Journal Of Veterinary Sciences
RAPD-PCR and phylogenetic analysis of E. coli isolated from human and cattle urinary tract infections
...Show More Authors

This study aimed at isolating uropathogenic Escherichia coli from urinary tract infections (UTIs) of human and cattle to examine the molecular diversity and phylogenetic relationship of the isolates. A total of 100 urine samples were collected from UTIs of human and cattle. The isolates identification was done using routine diagnostic methods and confirmed by Vitek2. Antimicrobial susceptibility was tested against 10 antimicrobials. Random amplified polymorphic DNA (RAPD)-polymerase chain reaction (PCR) was applied to identify the genetic diversity among E. coli isolates from human and animal origin by using five different octamer primers. The gelJ software for the phylogenetic analysis created Dendrograms. Out of 50 human urine samples, E.

... Show More
View Publication Preview PDF
Scopus (7)
Scopus Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Biogas Recovery from Anaerobic Co-Digestion of Poultry House Wastes for Clean Energy Production
...Show More Authors

Anaerobic digestion is a technology widely used for treatment of organic waste for biogas production as a source for clean energy. In this study, poultry house wastes (PHW) material was examined as a source for biogas production. The effects of inoculum addition, pretreatment of the substrate, and temperature on the biogas production were taken into full consideration. Results revealed that the effect of inoculum addition was more significant than the alkaline pretreatment of raw waste materials. The biogas recovery from inoculated waste materials exceeds its production from wastes without inoculation by approximately 70% at mesophilic conditions. Whereby, the increase of biogas recovery from pretreated wastes was by 20% higher than its

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
The use of laurylamine hydrocholoride CH3(CH2)11 NH3 –Cl for secondary oil recovery
...Show More Authors

Laurylamine hydrochloride CH3(CH2)11 NH3 – Cl has been chosen from cationic surfactants to produce secondary oil using lab. model shown in fig. (1). The relationship between interfacial tension and (temperature, salinity and solution concentration) have been studied as shown in fig. (2, 3, 4) respectively. The optimum values of these three variables are taken (those values that give the lowest interfacial tension). Saturation, permeability and porosity are measured in the lab. The primary oil recovery was displaced by water injection until no more oil can be obtained, then laurylamine chloride is injected as a secondary oil recovery. The total oil recovery is 96.6% or 88.8% of the residual oil has been recovered by this technique as shown

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri May 31 2024
Journal Name
Chemical Papers
Experimental investigation of low salinity water to improve oil recovery at Nassiriyah oil field
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
The Relationship Between the Above-Ground Biomass and the Vegetation Cover Indices at Different Salinity Levels
...Show More Authors
Abstract<p>The current study was carried out to find out the relationship between the Above-Ground Biomass and the spectral vegetative indices (Normalized Difference Vegetation Index, Soil Adjusted Vegetation Index, Difference Vegetation Index) (NDVI, SAVI, DVI) for soils with different salinity levels. Al Salamiyat Project was chosen as a study area located at an altitude of 34 m above sea level and within the geographical coordinates (E 44°.09´13.65´´ N 33°.25´ 07.87´´ and E 44°.17´ 46.03´´ N 33°.2l´40.72´´), with a total area of 14265 Dunum. Surface and subsurface soil samples were chosen from the study area and according to the previously defined salinity units, except for th</p> ... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Oct 28 2024
Journal Name
Deep Underground Science And Engineering
Ground vibration isolation using mass scatters: A comparative study with trench barriers and wave‐impeding blocks
...Show More Authors
Abstract<p>Traffic‐induced ground vibrations cause significant problems for residents and nearby structures. Reducing the effect of these vibrations on the neighboring environment is a key challenge, particularly in urban areas. This study presents both numerical and experimental investigations of the performance of mass scatters for screening ground vibrations. A three‐dimensional numerical model is validated and extended to conduct a comparative study on the efficiency of three geotechnical methods of isolation. These methods include trench barriers, wave‐impeding blocks (WIBs), and mass scatters. The results showed that mass scatters represent an efficient way of scattering ground vi</p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (6)
Scopus Crossref
Publication Date
Wed Sep 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of medicinal compounds from botanicals using bulk liquid membrane in rotating film contactor: Recovery of vinblastine from catharanthus roseus.
...Show More Authors

The interest of application of liquid membrane (pertraction) processes for recovery of medicinal compounds from dilute ammoniacal leach solutions is demonstrated. Selectivity of the liquid membrane ensures a preferential transport of the desired solute from the native extract into the strip solution, vinblastine was successfully extracted from basic media (pH 9.2) and stripped by acidic media of sulfuric acid (pH= 1.3) applying continuous pertraction in a rotating discs contactor and using n-decane as liquid membrane. Transport of vinblastine in three-liquid-phase system was studied and performed by means of a kinetic model involving two consecutive irreversible first-order reactions. The kinetic parameters (apparent rate constants of th

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Bioadsorption of Heavy Metals From Industrial Wastewater Using Some Species of Bacteria
...Show More Authors

Three isolated bacteria were examined to remove heavy metals from the industrial wastewater of the Diala State Company of Electrical Industries, Diyala-Iraq. The isolated bacteria were identified as Pseudomonas aeruginosa, Escherichia coli and Sulfate Reducing Bacteria (SRB). The three isolates were used as an adsorption factor for different concentrations of Lead and Copper (100, 150, and 200 ppm.), in order to examine the adsorption efficiency of these isolates. In addition, the effect of three factors on heavy metals adsorption were examined; temperature (25, 30, and 37 ?C), pH (3 and 4.5) and contact time (2 and 24 hrs). The results showed that the highest level of lead adsorption was obtained at 37 ?C by E. coli, P, aerugenosa and

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue May 30 2023
Journal Name
Iraqi Journal Of Science
Ground State Structure of Helium and Phosphorus Isotopes using the Radial Wave Functions of Harmonic-Oscillator and Hulthen Potentials
...Show More Authors

     The ground state density distributions and electron scattering Coulomb form factors of Helium (4,6,8He) and Phosphorate (27,31P) isotopes are investigated in the framework of nuclear shell model. For stable (4He) and (31P) nuclei, the core and valence parts are studied through Harmonic-oscillator (HO) and Hulthen potentials. Correspondingly, for exotic (6,8He) and (27P) nuclei, the HO potential is applied to the core parts only, while the Hulthen potential is applied to valence parts. The parameters for HO and Hulthen are chosen to reproduce the available experimental size radii for all nuclei under study. Finally, the CO component of electron scattering charge form factors are also investigated. Unfortunately, there is no

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Effect of Waste Water Bacteria and some chemical properties on drinking Water in AL-Mada,in Treatment Plan Station
...Show More Authors

Three stations were chosen on the water treatment plan of al- madaan .The Samples collected from the (Raw water) and the Sedimentation, filtration and storage water and the drinking water of outlet. Coliform densities T.S and F.C and TS and F.S and total bacterial count as bacteriological pollution indicators, as moste probable number (MPN) method was studied in test. Also some of the chemical characteristics of the water like pH , total suspended solid T.S.S, T.D.D.and S04 , T.Hardness , Ca++ , Mg++ . From the results it were indicated . The study showed the drinking water of outlet (distriputed in system) was agree with WHO criteria and Iraqi limits standards .

View Publication Preview PDF
Crossref