Preferred Language
Articles
/
FRaGq4sBVTCNdQwCc9Zx
Seasonal Variations of the Optimum Reliable Frequencies During Maximum and Minimum Periods of Solar Cycle 24
...Show More Authors

In this research, the seasonal Optimal Reliable Frequency (ORF) variations between different transmitter/receiver stations have been determined. Mosul, Baghdad, and Basra have been chosen as tested transmitting stations that located in the northern, center, and southern of Iraqi zone. In this research, the minimum and maximum years (2009 and 2014) of solar cycle 24 have been chosen to examine the effect of solar activity on the determined seasonal ORF parameter. Mathematical model has been proposed which leads to generate the Optimal Reliable Frequency that can maintain the seasonal connection links for different path lengths and bearings. The suggested ORF parameter represented by a different orders polynomial equation. The polynomial equation has been determined depending on different selected parameters (path length, bearing, time (day), months and BUF values). The suggested seasonal ORF parameter was examined for the three stations of the adopted years. The value of the seasonal ORF ionospheric parameter increased with the increase of path length and varies with the bearing between the transmitting and receiving stations also, the seasonal ORF values were higher at maximum solar cycle (2014) than the minimum solar cycle (2009).

Crossref
View Publication
Publication Date
Mon Oct 24 2022
Journal Name
Energies
Double-Slope Solar Still Productivity Based on the Number of Rubber Scraper Motions
...Show More Authors

In low-latitude areas less than 10° in latitude angle, the solar radiation that goes into the solar still increases as the cover slope approaches the latitude angle. However, the amount of water that is condensed and then falls toward the solar-still basin is also increased in this case. Consequently, the solar yield still is significantly decreased, and the accuracy of the prediction method is affected. This reduction in the yield and the accuracy of the prediction method is inversely proportional to the time in which the condensed water stays on the inner side of the condensing cover without collection because more drops will fall down into the basin of the solar-still. Different numbers of scraper motions per hour (NSM), that is

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
New Technique for Treatment of the dust accumulation from PV solar panels surface
...Show More Authors

One of the most important problems facing the world today is the energy problem. The solution was in finding renewable energy sources such as solar energy. The solar energy applications in Iraq is facing many problems . One of the most important problems is the accumulation of dust on the solar panels surface which causes decreasing its performance sharply. In the present work, a new technique was presented by using two-axis solar tracking system to reduce the accumulated dust on the solar panel surface and compared it with the fixed solar panels which installed at tilt angles 30° and 45°. The results indicated that the maximum losses of the output power due to accumulation of dust on the fixed solar panels is about 31.4% and 23.1% res

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH3 – H2O SYSTEM
...Show More Authors

This work was conducted to study the coefficient of performance for solar absorption refrigeration by using direct solar energy using aqueous ammonia 0.45 mass fraction (ammonia – water).The experiments were carried out in solar absorption system .The system consisted of solar collector generator (0.25 m × 0.25 m × 0.04m) and condenser cooled by a water bath followed by liquid receiver and evaporator. The results showed that the maximum generator temperature was (92° - 97°) during June 2009, and the minimum evaporator temperature was (5°C - 10°C) for aqua ammonia system.. It was, also, found that the coefficient of performance, cooling ratio and amount of cooling obtainable increased with increasing maximum generator temperature

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Renewable And Sustainable Energy Reviews
Review on the development of natural dye photosensitizer for dye-sensitized solar cells
...Show More Authors

View Publication
Scopus (372)
Crossref (349)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Full Text Book Of Minar Congress8
SECTION OF VETERINARY MEDICINE: MICROBIOLOGY, IMMUNITY AND VIROLOGY. THE BACTERIAL CONTAMINATION WITH PROTEUS AND E. COLI IN CERVIX AND UTERINE OF COWS DURING THE DIFFERENT ESTRUS PHASES
...Show More Authors

The herein research was carried out in order to identified the presence of bacteria in cervix and uterine lumen in Iraqi cattle during the different estrus phase with focusing on Protus and E coli. Estrus phases were determined by the structures which found on ovary (follicular growth for pro-estrus, mature growing follicle for estrus, hemorrhagic corpus luteam for meta-estrus and active corpus luteam for di-eatrus). Forty cervical swabs (ten for each estrus phase) and forty uterine swabs (ten for each estrus phase) were taken from macroscopically healthy reproductive animals after slaughtering and cultivated on nutrient agar and blood agar, the bacterial isolation were identified with biochemical teats. The present study found that

... Show More
Crossref
Publication Date
Sun Jun 05 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Level of professional pressures during the use of e-learning teaching method among teachers of the Faculties of Physical Education and Sports Sciences in Baghdad
...Show More Authors

View Publication
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Sat Oct 12 2019
Journal Name
Journal Of Engineering And Applied Sciences
Characterization of (CIGS)/(CdS) Hetrojunction for Solar Cell
...Show More Authors

The CIGS/CdS p-n junction thin films were fabricated and deposited at room temperature with rate of deposition 5, and 6 nm secG1 , on ITO glass substrates with 1mm thickness by thermal evaporation technique at high vacuum pressure 2×10G5 mbar, with area of 1 cm2 and Aluminum electrode as back contact. The thickness of absorber layer (CIGS) was 1 µm while the thickness of the window layer CdS film was 300 nm. The X-ray Diffraction results have shown that all thin films were polycrystalline with orientation of 112 and 211 for CIGS thin films and 111 for CdS films. The direct energy gaps for CIGS and CdS thin films were 1.85 and 2.4 eV, respectively. Atomic Force Microscopy measurement proves that both films CIGS and CdS films have nanostru

... Show More
Publication Date
Sun Jun 30 2019
Journal Name
Journal Of Engineering
Thermal Performance of Plastic Receiver in Solar Collector
...Show More Authors

A plastic tubes used as absorber of active flat plate solar collector (FPSC) for heating water were studied numerically and experimentally. The set-up is located in Babylon (republic of Iraq) 43.80 East longitude and 32.30 North latitude with titled of 450 toward the south direction.  The study involved three dimensions mathematical model for flat coil plastic absorber which solved by FLUENT-ANSYS-R.18 program. Experiments were conducted at outdoor conditions for clear days on January and February 2018 with various water volume flow rates namely (500, 750, 1000, 1250, and 1500 Liter per hour LPH) on each month for Reynolds number range of (1 x 104 to 5 x 104) th

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Sep 06 2020
Journal Name
European Journal Of Dental Education
Evaluation of technology‐based learning by dental students during the pandemic outbreak of coronavirus disease 2019
...Show More Authors

View Publication
Crossref (54)
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Modern Sport
Vertical Resistance and Its Relationship with Speed-Strength and Biomechanical Variables During the Takeoff Phase and the Performance of Selected Activities in Individual and Team Sports
...Show More Authors

Jumping ability is a fundamental variable in many sports, as its execution requires an integration of muscular strength Q1 and certain biomechanical variables. This is particularly evident in gymnastics jumping events and jump shots in ball games, both of which rely on a high level of vertical resistance. Vertical resistance serves as an indicator of an athlete’s ability to overcome their body weight while counteracting gravitational force to achieve optimal performance. As such, it is considered one of the key factors in movements that demand explosive power and speed. The researchers believe that despite the significant relationship between vertical resistance, speed-strength of the arms and legs, and certain biomechanical varia

... Show More
View Publication
Crossref (1)
Crossref