Lowering specific energy consumption (SEC) in reverse osmosis (RO) plants is one of the most important criteria in water treatment industry. The present work focused on best suggested RO pilot plant configurations for minimizing specific energy consumption, finding the best configurations experimentally to recover the water with minimizing salts in permeate side in RO module, study the factors affecting the performance of single and two stage systems, TFC membrane is used in spiral wound module. Brackish water is used as feed solution with different concentrations (2000, 3000, 4000 and 5000 ppm). The operating parameters studied were permeate flux, rejection and SEC. The experimental results showed the permeate concentration increased and water flux decreased with increasing in time from 0 to 60 min if concentrated stream at any ratio recycled to feed vessel. Also, the permeate concentrations increased and flux decreased with increasing in feed concentrations from 2000 to 5000 mg/L. At fixed operational pressure, rising of pressure from 4 to 7 bar extract more flux and permeate concentration decreased, in fixed feed concentration, for single stage operation mode, recycling 50% permeate to the feed makes the best permeate flux and the lowest SEC, for C f = 2000 ppm, Jw = 12.03 LMH and SEC = 0.551 kWh/m3, for the two stage operation mode, recycling 50% of permeate first stage and second one to the feed of second stage system has the best results that average J w = 10.746 and 10.623 LMH for the first stage and second respectively with total SEC = 0.55 kWh/m3.
In this paper the process of metal ions extraction (Zn(II) and Cu(II)) was studied in PEG-KCl aqueous two phase system was investigated without using an extracting agent. The experimental runs were performance at constant temperature (25 oC), constant mixing time (30 min), and constant PH of the solution (about 3). The effect of KCl salt concentration (from 10% to 25%), volumetric phase ratio of PEG solution to KCl solution (from 0.5 to 2), and the initial metal ion concentration (from 0.25 ml to 2 ml of 1 gm/L solution) were investigated on the percent extraction of Zn(II) and Cu(II). The results indicated that the percent extraction of metal ions increase with increasing of salt concentration and phase ratio, and slightly de
... Show MoreThe aim of the current research is to analyze the content of the two science books (chemistry units) for the two grades ( first and second intermediate ) according to environmental ethics, as the research community and its sample of the two science books (chemistry units) for the two grades ( first and second intermediate ), approved by the Iraqi Ministry of Education for the academic year ( 2021-2022 ), and the two researchers adopted the descriptive ( analytical ) approach, and the researchers built a standard for environmental ethics, and the validity of the tool was confirmed by presenting it to a group of experts, and then the researchers analyzed the two books in light of the standard prepared based on the implicit explicit idea, and
... Show MoreTo develop a petrol engine so that it works under the bi-engine pattern (producer gas-petrol) without any additional engine modifications, a single-point injection method inside the intake manifold is a simple and inexpensive method. Still, it leads to poor mixing performance between the air and producer gas. This deficiency can cause unsatisfactory engine performance and high exhaust emissions. In order to improve the mixing inside the intake manifold, nine separate cases were modelled to evaluate the impact of the position and angle orientation inside the intake manifold on the uniformity and spread of the mixture under AFR=2.07. A petrol engine (1.6 L), the maximum engine speed (8000 rpm), and bi-engine mode (petrol-producer ga
... Show MoreL1 adaptive controller has proven to provide fast adaptation with guaranteed transients in a large variety of systems. It is commonly used for controlling systems with uncertain time-varying unknown parameters. The effectiveness of L1 adaptive controller for position control of single axis has been examined and compared with Model Reference Adaptive Controller (MRAC). The Linear servo motor is one of the main constituting elements of the x-y table which is mostly used in automation application. It is characterized by time-varying friction and disturbance.
The tracking and steady state performances of both controllers have been assessed fo
... Show MorePhase change materials are known to be good in use in latent heat thermal energy storage (LHTES) systems, but one of their drawbacks is the slow melting and solidification processes. So that, in this work, enhancing heat transfer of phase change material is studied experimentally for in charging and discharging processes by the addition of high thermal conductive material such as copper in the form of brushes, which were added in both PCM and air sides. The additions of brushes have been carried out with different void fractions (97%, 94% and 90%) and the effect of four different air velocities was tested. The results indicate that the minimum brush void fraction gave the maximum heat transfer in PCM and reduced the time
... Show More