Background: The objective of this study was to investigate the possibility of standardizing the Bolton ratio analysis as a diagnostic measure for both Iraqi and Egyptian orthodontic populations within three Angle' classification groups. Materials and methods: Two hundred forty pretreatment study casts (one hundred twenty of each population) were included in this study and divided into three Angle' classification groups. The mesiodistal crown diameters of all teeth were measured for computing the anterior and total Bolton ratios. Analysis of variance was performed to compare the mean ratios of Bolton analysis as a function of the Angle classification.HSD test was used to specify the classes of malocclusion that have significant differences.
... Show MoreAbstract Background The aim of this study was to identify differences in oral cancer incidence among sexes, age groups and oral sites over time in Iraqi population. Methods Data was obtained from Iraqi cancer registry, differences and trends were assessed with the Wilcoxon matched-pairs signed-ranks test and Regression test, respectively. Results In Iraq from 2000 to 2008, there were 1787 new cases of oral cancer registered, 1035 in men and 752 in women. Cancer at all oral sites affected men more than women. The Tongue other (ICD-02) is the most frequent site follow by lip (ICD-00). Conclusion The decrease in the percent of oral cancer incidence in Iraq not compatible with the high percent of exposure to the risk factors, Iraqi cancer regis
... Show MoreBackground: Potentially malignant oral disorders (PMODs) are common precursors of oral squamous cell carcinoma (OSCC). Neoangiogenesis and signalling are important intermediate biomarkers that may govern the progression of dysplastic mucosa into carcinoma. Aims: Evaluate the importance of CD34 and Wnt3 expression in PMODs and OSCCs in relation to their clinicopathological parameters. Settings and Design: Prospective cross-sectional study. Materials and Methods: Immunohistochemical staining for CD34 and Wnt3 was performed for 41 samples. These included 27 PMODs, six OSCCs and eight normal gingival and alveolar mucosa. Analysis of variance (ANOVA) and post-hoc tests were applied. P<0.05 was considered statistically significant. Results: CD34
... Show MoreIn this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed
A theoretical and experimental investigation was carried out to study the behavior of a two-phase closed thermosyphon loop (TPCTL) during steady-state operation using different working fluids. Three working fluids were investigated, i.e., distilled water, methanol, and ethanol. The TPCTL was constructed from an evaporator, condenser, and two pipelines (riser and downcomer). The driving force is the difference in pressure between the evaporator and condenser sections and the fluid returns to the heating section by gravity. In this study, the significant parameters used in the experiments were filling ratios (FR%) of 50%, 75%, and 100% and heat-input range at the evaporator section of 215-860.2 W. When the loop reached to
... Show MoreIn this study, thermal characteristics of a two-phase closed heat pipe were investigated experimentally and theoretically. A two-phase closed heat pipe (copper container, Fluorocarbon FC-72 (C6F14) working fluid) was fabricated to examine its performance under the effect of input heat flux range of 250–1253 W/m2 , 70% fill charge ratio and various tilt angles. The temperature distribution along the heat pipe, input heat to evaporator section, and output heat from condenser were monitored. A comprehensive mathematical model was developed to investigate the steadystate heat transfer performance of a two-phase closed heat pipe. A steady state analytical model, is presented to determine important parameters on the design of two-phase close
... Show MoreObjective: The aim of this study was to develop a bioadhesive gel of gatifloxacin for the treatment of periodontal diseases.Methods: Periodontal gels of gatifloxacin were prepared using different hydrophilic polymers such as carbopol 940 (CP 940), carboxymethyl cellulose (CMC) and hydroxypropylmethyl cellulose (HPMC) in varied concentrations, either alone or as a combination. The prepared gels were evaluated for their physical appearance, pH, drug content, viscosity, bioadhesiveness and in vitro drug release profile. The influence of the type and the concentration of polymer on the drug release as well as on viscosity and mucoadhesiveness of prepared gels were investigated.Results: The prepared gels showed acceptable physical proper
... Show MoreFLI1 is a member of ETS family of transcription factors that regulate a variety of normal biologic activities including cell proliferation, differentiation, and apoptosis. The expression of FLI1 and its correlation with well-known breast cancer prognostic markers (ER, PR and HER2) was determined in primary breast tumors as well as four breast cancer lines including: MCF-7, T47D, MDA-MB-231 and MDA-MB-468 using RT-qPCR with either 18S rRNA or ACTB (β-actin) for normalization of data. FLI1 mRNA level was decreased in the breast cancer cell lines under study compared to the normal breast tissue; however, Jurkat cells, which were used as a positive control, showed overexpression compared to the normal breast. Regarding primary breast carcinoma
... Show MoreHydrate dissociation equilibrium conditions for carbon dioxide + methane with water, nitrogen + methane with water and carbon dioxide + nitrogen with water were measured using cryogenic sapphire cell. Measurements were performed in the temperature range of 275.75 K–293.95 K and for pressures ranging from 5 MPa to 25 MPa. The resulting data indicate that as the carbon dioxide concentration is increased in the gas mixture, the gas hydrate equilibrium temperature increases. In contrast, by increasing the nitrogen concentration in the gas mixtures containing methane or carbon dioxide decreased the gas hydrate equilibrium temperatures. Furthermore, the cage occupancies for the carbon dioxide + methane system were evaluated using the Van der Wa
... Show More