In petroleum refineries, cooling towers, steam engines, and vacuum distillation all require a large volume of water. Before being dumped into the water bodies, it is then transported to an industrial water treatment facility. One of the study's objectives is to verify how well different processing units in the industrial wastewater treatment plant at the cycle refinery remove concentrations of chemical and biological oxygen demand (COD) and BOD. Five samples of industrial wastewater were collected before and after each treatment unit and one sample of wastewater was drained as a final product to the Tigris River. Over the summer, the BOD5 values after each processing unit were 180.8, 175.2, 111, 43, and 37 ppm. Winter readings were 106.8, 99.6, 81.2, 33.8, and 31 ppm, with summer and winter complete elimination rates of 79% and 71%, respectively. The reason for higher BOD5 concentrations in summer than in winter is due to higher temperatures that lead to evaporation and increased concentrations of BOD5 and COD pollutants. While COD concentrations were during the summer after each processing unit 399.6, 383.2, 187.2, 72.8, and 55.4 ppm, in winter they were 324.4, 310.2, 115, 46, and 42.6 ppm with a total removal rate of 86% in summer and 87% in winter. It was found that the refinery's water-drained treatment method, which includes a high proportion of BOD5 and COD concentrations in the main treatment plant, is effective. The water that flowed from the treatment plant into the river was within the national standard of the river water.
Al-Chibayish Marsh (CM) is considered as the major part of Central Marshes area of this marsh is 1050 Km². The water quality of these marshes is suffering from salt accumulation due to intensive dam construction, limited supply of water from sources, climate change impacts, and the absence of outlet flow from these marshes, specifically at low flow periods. So, the current research aims to assess and improve these marshes' hydraulic behavior and water quality and define the best location for outlet drains. Field measurements and laboratory tests were conducted for two periods (November 2020 and February 2021) to define the (TDS) concentrations at nine different locations. Samples were also examined for water's phy
... Show MoreAn infant incubator in the neonatal intensive care unit (NICU) is a medical instrument of care that provides oxygen, warmth and moisture to a newborn baby. Due to environmental conditions affecting the infants foster babies may experience discomfort and pain at some point. Thus, this study aimed to assess ambient air quality in neonatal incubators to improve the environmental quality of neonatal intensive care units and safety. Air pollutants concentrations consisting of particulate matter (pm2.5, pm10), hydrocarbons (HOCH), volatile organic compounds (VOC), air quality index (AQI), humidity and temperature, were measured at four selected Baghdad hospitals (Al-Karkh and Rusafa) . The results showed that the increase in rela
... Show MoreOily carwash wastewater is a high organic and chemical wastewater. This paper targeted to investigate a treatment to decrease the water consumption and contaminants in car-washing stations. Electrocoagulation combined with ultrasonic energy (Sono-Electrocoagulation) was suggested so that the carwash wastewater is treated to be reused. The effect of both the voltage and time of treatment on the removal of COD, turbidity, conductivity, and total dissolved solids (TDS) were studied at constant initial pH 7 and electrode distance 2 cm. The results showed the best results of removal COD, turbidity, TDS, and reduce electrical conductivity is when the voltage was 30 V and a treatment time of 90 minutes.
<
... Show MoreThis study investigated the treatment of dairy wastewater using the electrocoagulation method with iron filings as electrodes. The study dealt with real samples collected from local factory for dairy products in Baghdad. The Response Surface Methodology (RSM) was used to optimize five experimental variables at six levels for each variable, for estimating chemical oxygen demand (COD) removal efficiency. These variables were the distance between electrodes, detention time, dosage of NaCl as electrolyte, initial COD concentration, and current density. RSM was investigated the direct and complex interaction effects between parameters to estimate the optimum values. The respective optimum value was 1 cm for the distance between electrodes, (6
... Show MoreThe study aimed to spread the culture of efficient performance between nursing staffs, which would contribute and achieve health care quality, and to clarify the role of nursing in improving the quality of high-quality health care, as well as to clarify how to reach national standards for the quality of health care in Iraq, Therefore, the study dealt with the efficiency of nursing performance as an explanatory variable, and the quality of health care as a dependent variable. The fact that the health sector is the foundation for building a healthy society free from diseases, so hospital of IBN AL-NAFIS as an institution and it's nursing teams were taken as a community for this study. The results to be objective and reflect the rea
... Show MoreBackground: World Health Organization (WHO) and United Nation International Children Fund (UNICEF) developed a strategy known as Integrated Management of Childhood Illness (IMCI); which aims to reduce less than five years children morbidity and mortality in developing countries.
Objective: To assess the completion of the IMCI format status in primary health care centers, Baghdad.
Methods: A cross sectional study with analytic element was conducted during the period from 15th of January till 15th May 2016 in selected Primary health centers in Baghdad, Iraq. The sample consists of form of child files less than 2 months and form from 2
... Show MoreA procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using t
... Show MoreVascular plants that have been identified during the study seasons in the Island. The cultivated plants were 126 species belong to 103 genera and to 49 families of the year 2001-2002 . The natural vegetation in this Island has been subjected to a total disturbance and subsidence due to the comprehensive turbidity of the Island environment.Number of names of that natural vegetation has been mentioned in the study within the weed plants.The results of the study of the period of flowering and their attitudes show clear seasonal differences. During the cold months of winter, the number of the cultivated and the natural plants was at the rate of 15%.These kinds of flowers require high level of care to increase their numbers. While in the spring
... Show MoreThe gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa