Preferred Language
Articles
/
EeaOd50BmraWrQ4dtll7
Industrial Wastewater Efficiency Assessment of Al-Dora Refinery Plant in Baghdad by Decreasing BOD5 and COD Concentrations
...Show More Authors

In petroleum refineries, cooling towers, steam engines, and vacuum distillation all require a large volume of water. Before being dumped into the water bodies, it is then transported to an industrial water treatment facility. One of the study's objectives is to verify how well different processing units in the industrial wastewater treatment plant at the cycle refinery remove concentrations of chemical and biological oxygen demand (COD) and BOD. Five samples of industrial wastewater were collected before and after each treatment unit and one sample of wastewater was drained as a final product to the Tigris River. Over the summer, the BOD5 values after each processing unit were 180.8, 175.2, 111, 43, and 37 ppm. Winter readings were 106.8, 99.6, 81.2, 33.8, and 31 ppm, with summer and winter complete elimination rates of 79% and 71%, respectively. The reason for higher BOD5 concentrations in summer than in winter is due to higher temperatures that lead to evaporation and increased concentrations of BOD5 and COD pollutants. While COD concentrations were during the summer after each processing unit 399.6, 383.2, 187.2, 72.8, and 55.4 ppm, in winter they were 324.4, 310.2, 115, 46, and 42.6 ppm with a total removal rate of 86% in summer and 87% in winter. It was found that the refinery's water-drained treatment method, which includes a high proportion of BOD5 and COD concentrations in the main treatment plant, is effective. The water that flowed from the treatment plant into the river was within the national standard of the river water.

Scopus Crossref
View Publication
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effects of Operating Variables on Efficancy of Water Disinfection by Sodium Hypochlorite Using Al-Wathba Wastewater
...Show More Authors

The aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Ecological Engineering
Explore the Impact of Surfactant Type on the Stability and Separation Efficiency of Oil–Water Emulsions of Real Wastewater from Al-Basrah Crude Oil Using Microbubble Air Flotation
...Show More Authors

Among several separation processes, the air flotation distinguish as remarkably high potential separation process related to its high separation efficiency and throughput, energy-efficient, simple process, cost-effective, applicable to a wide range of oily wastewater and no by-products. The current study aimed to investigate the effect of the type and concentration of surfactant on the stability of oil-water emulsion and efficiency of the separation process. For this purpose, three types of surfactant where used (anionic SDS, mixed nonionic Span 85/Tween 80, and cationic CTAB). The results demonstrated that the Span 85/Tween 80 surfactant has the best stability, and it increases with the surfactant concentration augmentation. The removal ef

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Dec 05 2022
Journal Name
Baghdad Science Journal
Land use change in Baghdad City and assessment of the Jadriyah and Umm Al- Khanazeer Island Important Bird Area (IBA) from 1984 to 2020
...Show More Authors

Land use change, particularly the expansion of urban areas and associated human activities at the expense of natural and semi-natural areas, is a major ecological issue in urban areas around the world. Climate change being a very strong additional driver for changing the temperature and habitat in the cities. This also applies to Baghdad, Iraq, where urbanisation and climate change exerts a major pressure on the natural habitats of the city, and thus may affect the ability of city planners to adapt to future climate change scenarios. Here we present evidence of substantial growth in urban areas, increases in temperature, and degradation of natural vegetation within Baghdad city by using Remote Sensing techniques and an assessment for the

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (7)
Scopus Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More
Publication Date
Fri Mar 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Low Carbon Steel in Different HCl Concentrations by Phenythiourea
...Show More Authors

Phenylthiourea  (PHTU),was  tested  as  inhibitor for  the  corrosion  of  low  carbon  steel  in different  HCI  acid concentration by mass loss ,and polarization measurements .it was found that (PHTU) is a good inhibitor for the corrosion of low carbon steel in 1,3,and 5N HCI solution ,and its inhibition efficiency (0) increases with its concentration and attains approximately 97% at l g/I .polarization curves indicate that (PHTU) acts as an anodic type inhibitor .the inhibitor was adsorbed on the low carbon steel surface according to the Langmuir adsorption isotherm model. Results show that the rate of corrosion of low carbon steel increased with increasing temperature o

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 06 2025
Journal Name
Plasmonics
Removal of Mercury Hg(II) from Industrial Wastewater by Formation of TiO₂@Ag/HNT Nanocomposite Using Bio-microwaved Synthesized TiO₂@Ag NPs (Core Shell)
...Show More Authors

An environmentally friendly technique was used to prepare titanium dioxide@ silver (core shell) (TiO₂@Ag NPs) using chard leaf extract, a natural stabilizer and reductant. A nanocomposite (NCs) of TiO₂@Ag supported by halloysite nanotubes (HNTs), TiO2@Ag/HNT NCs, was prepared under microwave irradiation. The microwave technique is used to accelerate the reaction and enhance the homogeneity of nanoparticle distribution. Spectroscopic and structural analyses were performed on the resulting nanocomposite. X-ray diffraction (XRD) revealed a clear crystalline structure with grain sizes ranging from 7 to 15 nm, with an average of ~11 nm, the transmission electron microscope (TEM) revealed that the size of nanoparticles in the TiO₂@Ag/HNT N

... Show More
Scopus Crossref
Publication Date
Mon Oct 06 2025
Journal Name
Plasmonics
Removal of Mercury Hg(II) from Industrial Wastewater by Formation of TiO₂@Ag/HNT Nanocomposite Using Bio-microwaved Synthesized TiO₂@Ag NPs (Core Shell)
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Apr 30 2025
Journal Name
International Journal Of Environmental Impacts
Analysis of the Effect of Heavy Elements in Polluted Industrial Water and its Environmental Treatment: An Applied Study on the Gas Power Plant/ 1 (Central Region) in Southern Baghdad and its Discharge into the Tigris River
...Show More Authors

Water produced from power plants is one of the most important sources of water pollution, especially for areas like Baghdad, Contaminated industrial wastewater is a major environmental challenge due to the rapid growth of industries, leading to increased accumulation of harmful pollutants in water resources, the work is intended to study the impact of water generated from a power plant in the south on the level of heavy metals before and after the treatment process and after its discharge to the Tigris River. Objective is to determine the extent of heavy metals such as iron, copper, chromium, and zinc concentration in water extracted from various points and subsequently study the monthly variations of these elements with a view to assessmen

... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Measurement the Concentrations of Radon and Thoron and Their Progeny in the Air Samples of Al-Haswaa City in Babylon province
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Dec 07 2008
Journal Name
Baghdad Science Journal
Measurements of Radon-222 and its Daughters Concentrations in Buildings of Department Physics in College of Sciences of Baghdad University
...Show More Authors

The present work aims to investigate approaches, measures and detection of indoor radon level in buildings of the department of physics in college of science of Baghdad University. CR-39 solid state nuclear track detectors were used to measure the radon concentrations inside the rooms, including five laboratories and five workplace rooms in ground and first storey of the department. The average radon concentration at first storey was found to be 43.1±13.2 Bq/m3 and 40.1±13.4 Bq/m3 at the ground storey. The highest level of radon concentration at the first storey in the radioactive sources store was 87.5±29 Bq/m3 while at the ground storey in room(2) was 70.2±24 Bq/m3 which is due to the existence radioactive sources in some selected

... Show More
View Publication Preview PDF
Crossref