Preferred Language
Articles
/
ERjiW5QBVTCNdQwC9BMU
Capacitance and Resistivity Measurements of Polythiophene /Metallic Nanoparticles-based Humidity Sensors
...Show More Authors

Capacitive–resistive humidity sensors based on polythiophene (P3HT) organic semiconductor as an active material hybrid with three types of metallic nanoparticles (NP) (Ag, Al, and Cu) were synthesized by pulsed laser ablation (PLA). The hybrid P3HT/metallic nanoparticles were deposited on indium-tin-oxide (ITO) substrate at room temperature. The surface morphology of theses samples was studied by using field emission scanning electron micrographs (FE-SEM), which indicated the formation of nanoparticles with grain size of about 50nm. The electrical characteristics of the sensors were examined as a function of the relative humidity levels. The sensors showed an increase in the capacitance with variation in the humidity level.  While the resistivity While the resistivity decrease nonlinearity in the variation of humidity level from 10% to 100%.. The results show that the recovery and response times were higher for the Al/P3HT/Cu/Al sensor compared with those of the other nanoparticles.   

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 21 2015
Journal Name
Environmental Monitoring And Assessment
Water quality monitoring of Al-Habbaniyah Lake using remote sensing and in situ measurements
...Show More Authors

View Publication
Scopus (37)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Thu Apr 18 2024
Journal Name
Geomatics And Environmental Engineering
Error Analysis of Stonex X300 Laser Scanner Close-range Measurements
...Show More Authors

This research reports an error analysis of close-range measurements from a Stonex X300 laser scanner in order to address range uncertainty behavior based on indoor experiments under fixed environmental conditions. The analysis includes procedures for estimating the precision and accuracy of the observational errors estimated from the Stonex X300 observations and conducted at intervals of 5 m within a range of 5 to 30 m. The laser 3D point cloud data of the individual scans is analyzed following a roughness analysis prior to the implementation of a Levenberg–Marquardt iterative closest points (LM-ICP) registration. This leads to identifying the level of roughness that was encountered due to the range-finder’s limitations in close

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Apr 01 2018
Journal Name
Iraqi Journal Of Science
Estimation of The Zenith Path Delay using RTK-DGPS measurements
...Show More Authors

In this paper, the method of estimating the variation of Zenith Path Delay (ZPD) estimation method will be illustrate and evaluate using Real Time Kinematic Differential Global Positioning System (RTK-DGPS). The GPS provides a relative method to remotely sense atmospheric water vapor in any weather condition. The GPS signal delay in the atmosphere can be expressed as ZPD. In order to evaluate the results, four points had been chosen in the university of Baghdad campus to be rover ones, with a fixed Base point. For each rover position a 155 day of coordinates measurements was collected to overcome the results. Many models and mathematic calculations were used to extract the ZPD using the Matlab environment. The result shows that the ZPD valu

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Apr 21 2023
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees22fr
Effect of Ag doping on optical constant and hall effect measurements of SnS thin films
...Show More Authors

In this report Silver doped Tin Sulfide (SnS) thin films with ratio of (0.03) were prepared using thermal evaporation with a vacuum of 4*10-6 mbar on glass with (400) nm thickness and the sample annealing with ( 573K ). The optical constants for the wavelengths in the range (300-900) nm and Hall effect for (SnS and SnS:3% Ag) films are investigated and calculated before and after annealing at 573 K. Transition metal doped SnS thin films the regular absorption 70% in the visible region, the doping level intensification the optical band gap values from 1.5- 2 eV. Silver doped tin sulfide (SnS) its direct optical band gap. Hall Effect results of (SnS and SnS:3% Ag) films show all films were (p-type) electrical conductivity with resistivity of

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 16 2021
Journal Name
Application Of Optical Fiber In Engineering
Modified Single Mode Optical Fiber Ammonia Sensors Deploying PANI Thin Films
...Show More Authors

Modified optical fiber sensors received increasing attention because of their superior properties over electrical sensors. These properties include their immunity towards electromagnetic interference and the ability to be deployed in corrosive and volatile environment. Several optical fiber platforms have been developed for chemical sensing applications based on modifying optical fiber cladding layer such as etched, tapered, D-shaped and etched-tapered. The modifications purpose is to extend the evanescent wave propagating out of the core physical dimensions. Thus, evanescent wave interaction with analyte is enhanced. Modified optical transducing platforms are integrated in gas sensing applications, such as ammonia. Modified optical

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Impact of geometric factor in accumulation factor measurements of gamma rays
...Show More Authors

In this research a study process to calculate the factor accumulation of gamma rays for aluminum and exporters cobalt 60 Mika Atktron volts and actively radiation Vdrh 1.406 Mika Bq been studying the effect of the angle of reimbursement and the distance between the shield and detector In measurements factor accumulation Adhrt results in line with the theoretical results published

View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Bioautomation
Model for Prediction of the Weight and Height Measurements of Patients with Disabilities for Diagnosis and Therapy
...Show More Authors

Background: Accurate measurement of a patient’s height and weight is an essential part of diagnosis and therapy, but there is some controversy as to how to calculate the height and weight of patients with disabilities. Objective: This study aims to use anthropometric measurements (arm span, length of leg, chest circumference, and waist circumference) to find a model (alternatives) that can allow the calculation of the height and the body weight of patients with disabilities. Additionally, a model for the prediction of weight and height measurements of patients with disabilities was established. Method: Four hander patients aged 20-80 years were enrolled in this study and divided into two groups, 210 (52.5%) male and 190 (47.5%) fe

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Fri Dec 06 2019
Journal Name
Karbala International Journal Of Modern Science
Stereo Photogrammetry vs Computed Tomography for 3D Medical Measurements
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Particle size effect on XRF measurements of Copper and Zinc particles suspended in hydrocarbon materials
...Show More Authors

Copper and Zinc powders with different particle sizes were subjected to sieving of range (20-100?m) and He-Ne laser system to determine the particle size . 1wt% from each powders was blended carefully with 99wt% from Iraqi oil . Microscopic examination were carried for all samples to reveal the particle size distribution . XRF intensity measurements were conducted for all suspended samples , and the relation between XRF intensity and the particle size was found .

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Aip Conference Proceedings
Performance measurements of single server fuzzy queues with unreliable server using left and right method
...Show More Authors

The fuzzy assignment models (FAMs) have been explored by various literature to access classical values, which are more precise in our real-life accomplishment. The novelty of this paper contributed positively to a unique application of pentagonal fuzzy numbers for the evaluation of FAMs. The new method namely Pascal's triangle graded mean (PT-GM) has presented a new algorithm in accessing the critical path to solve the assignment problems (AP) based on the fuzzy objective function of minimising total cost. The results obtained have been compared to the existing methods such as, the centroid formula (CF) and centroid formula integration (CFI). It has been demonstrated that operational efficiency of this conducted method is exquisitely develo

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref