The aim: Infection with the hepatitis B virus (HBV) caused by blood transfusion is a big problem throughout the world. The aim of study is to determine the faster and more accurate methods for detection of hepatitis B infections by serological screening and PCR- amplification. Materials and methods: A total of 140528 donors were tested for HBsAg and total anti-HBc from January to October 2021 in Iraq’s National Blood Transfusion Center; however, only 100 samples with HBsAg (-) and anti-HBc (+) were collected and tested for HBV DNA using quantitative real-time PCR. Results: From 2015 to 2021, the percentage of HBsAg positive donors was 0.33 percent in 2015, 0.32 percent in 2016, 0.30 percent in 2017, 0.28 percent in 2018, 0.23 percent in 2019, 0.22 percent in 2020, and 0.27 percent in 2021. Between January and October of 2021, the overall anti-HBc rate among the (140528) donors was 4.42 percent. According to our findings, only 7% of blood samples from NBTC donors with HBsAg (-) anti-HBc (+) were positive for HBV DNA. The results showed no significant change in HBs Ag (+) and total anti-HBc rates among blood donors between 2015 and 2021. Conclusions: HBV infection could be transmitted from a blood donor with OBI. PCR (RT PCR) is substantially more sensitive and effective. Despite this the use of an anti-HBc test for blood donors could be seen as a second choice to control HBV from spreading during blood transfusions.
This study investigated the shear performance of concrete beams with GFRP stirrups vs. traditional steel stirrups. Longitudinal glass fiber‐reinforced polymer (GFRP) bars were used to doubly reinforce the tested beams at both the top and bottom of their cross sections. To accomplish this, several stirrup spacings were provided. Eight beam specimens, measuring 300 × 250 × 2400 mm, were used in an experimental program to test under a two‐point concentrated load with an equal span‐to‐depth ratio until failure. Four beams in Group I have standard mild steel stirrups of 8 mm diameter, while four beams in Group II have GFRP stirrups with the same adopted diameter. The difference betwe
In this research, the covariance estimates were used to estimate the population mean in the stratified random sampling and combined regression estimates. were compared by employing the robust variance-covariance matrices estimates with combined regression estimates by employing the traditional variance-covariance matrices estimates when estimating the regression parameter, through the two efficiency criteria (RE) and mean squared error (MSE). We found that robust estimates significantly improved the quality of combined regression estimates by reducing the effect of outliers using robust covariance and covariance matrices estimates (MCD, MVE) when estimating the regression parameter. In addition, the results of the simulation study proved
... Show MoreWe study the physics of flow due to the interaction between a viscous dipole and boundaries that permit slip. This includes partial and free slip, and interactions near corners. The problem is investigated by using a two relaxation time lattice Boltzmann equation with moment-based boundary conditions. Navier-slip conditions, which involve gradients of the velocity, are formulated and applied locally. The implementation of free-slip conditions with the moment-based approach is discussed. Collision angles of 0°, 30°, and 45° are investigated. Stable simulations are shown for Reynolds numbers between 625 and 10 000 and various slip lengths. Vorticity generation on the wall is shown to be affected by slip length, angle of incidence,
... Show MoreIn this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
In current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show Moreسرطان البنكرياس هو مرض ذو معدل وفيات مرتفع، ولا يزال التشخيص المبكر لسرطان البنكرياس يمثل تحديًا. يظل معدل البقاء النسبي لمدة 5 سنوات أقل من 8%، والاستراتيجيات العلاجية غير فعالة في زيادة معدلات بقاء المريض على قيد الحياة. في خلايا سرطان البنكرياس، ارتبطت مقاومة العلاج بالتغيرات الجينية التي تؤدي إلى ظهور مسارات خلوية شاذة؛ ولذلك، هناك ما يبرر ايجاد استراتيجيات جديدة لعلاج هذا المرض. هنا، سعينا لاستكشاف
... Show MoreThe study aims to identify the educational research obstacles as perceived by the faculty members at the universities of south in the west bank. As for study population, it included all (60) faculty-member in the colleges of education (bait lahem, alahliyah, al-khalil, and al-Quds almaftoha). To collect study data, the researcher used a questionnaire that consisted of (43) item; it has categorized into seven-domains: academic working conditions, academic management, resources and information, faculty members, publication, planning, and funding educational research. The findings revealed that Educational research obstacles were high with an average of (4, 39), no significant differences among sample averages and stander deviations on the
... Show More