Preferred Language
Articles
/
EBdeSI8BVTCNdQwC8WlM
Geology, Pb and S Isotope Geochemistry, and Genesis of the Na Bop-Pu Sap Lead-Zinc Deposit in the Cho Don area, Northeastern Vietnam
...Show More Authors

The Na Bop-Pu Sap Pb-Zn ore bodies represent a typical vein-type lead-zinc deposit situated in the Cho Don area and are currently being extracted for their lead and zinc resources. This deposit is characterized by its significant scale and quality and is considered one of the prominent lead-zinc deposits in the Cho Don area. Despite its significance, this deposit has not received adequate attention, resulting in limited knowledge of its geology, mineralization, and deposit genesis model. To address this knowledge gap, our study utilized several methodologies, including field surveying, ore mineral analysis under a microscope, and S and Pb isotopic geochemistry. By employing these approaches, we were able to obtain specific insights into the origin of mineralization and the deposit model. Our field survey suggests that the ore deposits are formed as Pb-Zn-bearing veins along Devonian shale, claystone, and limestone faults. Microscopic analyses of the veins reveal the presence of galena, sphalerite, chalcopyrite, pyrite, arsenopyrite, and pyrrhotite as ore minerals, and quartz, calcite, dolomite, and chalcedony as gangue minerals. Sulfur-isotope values (δ34SCDT) of galena 5.3 to 0.1‰ (average 2.8‰), sphalerite 6.8 to 2.5‰ (average 5.3‰), and pyrite 5.8 to 4.1‰ (average 4.9‰) indicate that the sulfide mineralization may be related to a deep source, possibly originating from magmatic activity in the region and contaminated by carbonate-bearing marine sedimentary rocks. Lead-isotope studies indicate a model age of 598-424 Ma for the lead reservoir, consistent with the possible presence of local source rocks containing sulfur. The lead and sulfur in the ore veins were probably contaminated by Devonian carbonate-bearing marine sedimentary rocks and leached from Neoproterozoic to Cambrian magmatic activity. The lead-zinc deposits in Na Bop-Pu Sap do not display any Mississippi valley-type (MVT) or Sedimentary exhalative (SEDEX) lead-zinc deposit characteristics, as they appear to be related to shear zone-hosted lead-zinc deposits.

Scopus Crossref
View Publication
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Spectroscopic and structural properties of Zinc-Phthalocyanine prepared by pulsed laser deposition
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Apr 05 2019
Journal Name
International Journal Of Nanoelectronics And Materials
Characterization and Responsivity of Graphene Loaded Zinc Sulphide within Visible Light Spectrum
...Show More Authors

In this study, the nanocrystal-ZnS-loaded graphene was synthesized by a facile coprecipitation route. The effect of graphene on the characterization of Zinc Sulphide (ZnS) was investigated. The X-ray Diffraction (XRD) results reveal that ZnS has cubic system while hexagonal structure which is observed by loading graphene during the preparation of ZnS. Energy Dispersive X-ray Spectroscopy (EDS) analysis proved the presence of all expected elements in the prepared materials. Nanosize of fabricated materials has been measured using Scanning Electron Microscopy (SEM) technique. This study also found that the graphene plays a critical role in lowering the optical energy gap of ZnS nanoparticles from 4 eV to 3.2 eV. The characterization of detec

... Show More
Scopus (2)
Scopus
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study and Mathematical Modelling of Zinc Removal by Reverse Osmosis Membranes
...Show More Authors

In this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied. The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was found is 54.

... Show More
Preview PDF
Publication Date
Thu Nov 01 2012
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Direct melanocytes transplant from normal donor area into vitiliginous recipient area by dermabrasion technique
...Show More Authors

KE Sharquie, AA Noaimi, HA Al-Mudaris, Journal of Cosmetics, Dermatological Sciences and Applications, 2012 - Cited by 6

View Publication
Publication Date
Sat Nov 01 2014
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Therapeutic evaluation of 2% tea lotion in comparison with 5% zinc sulfate solution in the treatment of acne rosacea
...Show More Authors

KE Sharquie, AA Noaimi, SA Al-Hashimy, MM Al-Salih, Journal of Cosmetics, Dermatological Sciences and Applications, 2014 - Cited by 12

View Publication
Publication Date
Sun Jan 01 2023
Journal Name
Caspian Journal Of Environmental Sciences
Efficacy of nanoparticle zinc oxide in the resistance of fungus Rhizoctonia solani causing black scurf disease in local potatoes
...Show More Authors

Scopus (10)
Scopus
Publication Date
Mon Oct 28 2019
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Kinetic profile of silver and zinc oxide nanoparticles by intraperitoneal injection in mice , a comparative study
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Al-nahrain University
DETERMINATION OF SERUM TRACE ELEMENTSMAGNESIUM, COPPER, ZINC, AND SELENIUM IN ASTHMATIC PATIENTS BY ATOMIC ABSORPTION SPECTROPHOTOMETRY
...Show More Authors

The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in

... Show More
Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Bioremediation of Nickel and Lead contaminated soil by Vica faba L. plant and AM fungi Glomus mosseae
...Show More Authors

This study is conducted to determine the activity of plant Vica faba and two isolated from arbuscular mycorrhizae fungi (A,B) in bioremediation of soil pollution by Nickel and Lead elements in north and south of Baghdad city. The results showed that the average of soil pollution by Nickel and Lead elements in north of Baghdad was less than the average of soil pollution in the south of Baghdad which recorded 29.0,9.0PPm and 42.0, 25.0PPm respectively. The results show that the isolate A from the polluted soil is more active from isolate B which isolate from unpolluted soil for bioremediation. Vica faba recorded more in accumulate the Lead element in shoot system which was 19.65PPm and in root system was 27.2PPm and for Nickel element 24.65

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Separation of Lead (Pb2+) and Cadmium (Cd2+) from Single and Binary Salt Aqueous Solutions Using Nanofiltration Membranes
...Show More Authors

The present work reports on the performance of three types of nanofiltration membranes in the removal of highly polluting and toxic lead (Pb2+) and cadmium (Cd2+) from single and binary salt aqueous solutions simulating real wastewaters. The effect of the operating variables (pH (5.5-6.5), types of NF membrane and initial ions concentration (10-250 ppm)) on the separation process and water flux was investigated. It was observed that the rejection efficiency increased with increasing pH of solution and decreasing the initial metal ions concentrations. While the flux decreased with increasing pH of solution and increasing initial metal ions concentrations. The maximum rejection of lead and cadmium ion

... Show More
View Publication Preview PDF