Preferred Language
Articles
/
Dhf0m5IBVTCNdQwCS7oZ
UV Photovoltaic detector based on Bi doped TiO2 Fabricated by Pulse Laser Deposition
...Show More Authors

Pure and doped TiO 2 with Bi films are obtained by pulse laser deposition technique at RT under vacume 10-3 mbar, and the influence of Bi content on the photocvoltaic properties of TiO 2 hetrojunctions is studied. All the films display photovoltaic in the near visible region. A broad double peaks are observed around λ= 300nm for pure TiO 2 at RT in the spectral response of the photocurrent, which corresponds approximately to the absorption edge and this peak shift to higher wavelength (600 nm) when Bi content increase by 7% then decrease by 9%. The result is confirmed with the decreasing of the energy gap in optical properties. Also, the increasing is due to an increase in the amount of Bi content, and shifted to 400nm when annealed at 523 K as results of decreasing the energy gap

Publication Date
Thu Jan 01 2015
Journal Name
The 2d International Conference Of Buildings, Construction And Environmental Engineering (bcee2-2015)
Terrestrial Laser Scanning to Preserve Cultural Heritage in Iraq Using Monitoring Techniques
...Show More Authors

English

View Publication
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
Study of optical bistability in a fully optimized laser Fabry-Perot system
...Show More Authors

The analytical study of optical bistability is concerned in a fully
optimized laser Fabry-Perot system. The related phenomena of
switching dynamics and optimization procedure are also included.
From the steady state of optical bistability equation can plot the
incident intensity versus the round trip phase shift (φ) for different
values of dark mistuning 




12
,
6
,
3
,
1.5
0 , o
   
 or finesse (F= 1, 5, 20,
100). In order to obtain different optical bistable loops. The inputoutput
characteristic for a nonlinear Fabry-Perot etalon of a different
values of finesse (F) and using different initial detuning (φ0) are used
in this rese

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Design and study for transmitter system of laser Nd-YAG (1.06 ?m)
...Show More Authors

In this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.

View Publication Preview PDF
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
The Efficacy of (810 Nm) Diode Laser in Treatment of Idiopathic Epistaxis
...Show More Authors

There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2013
Journal Name
Optics & Laser Technology
Evaluation of PMMA joining to stainless steel 304 using pulsed Nd:YAG laser
...Show More Authors

This paper reports an experimental study of welding of dissimilar materials between transparent Polymethylmethacrylate (PMMA) and stainless steel 304 sheets using a pulsed mode Nd:YAG laser. The process was carried out for two cases; laser transmission joining (LTJ) and conduction joining (CJ). The former is achieved when the joint is irradiated from the polymer side and the latter when the joint is irradiated from the opposite side (metal side). The light and process parameters represented by the peak power (Pp), pulse duration (τ), pulse repetition rate (PRR), scanning speed (ν) and pulse shape have a significant effect on the joint strength (Fb), joint bead width (b), joint quality and appearance. The optimum parameters were determined

... Show More
View Publication
Scopus (79)
Crossref (71)
Scopus Clarivate Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Using of Laser Therapy in the Treatment of Patients With Plantar Fasciitis
...Show More Authors

Background: planter fasciitis is a common condition
seen in adults and sport men, it is characterized by dull
pain in the heel, especially when getting up and
standing on the foot in the morning or after sitting for a
long time.
Recently low level laser therapy is used as a method of
treatment.
Objective: to evaluate the benefit of laser therapy in
treatment of planter fasciitis.
Methods: Out of twenty five patients with planter
fasciitis exposed to laser therapy. Laser used is (diode
type) given in two cessions per week for four weeks,
time for each cession is about (12 minutes).
Results: complete recovery seen in (32%) of patients,
moderate improvement in (16%), mild improvement in
(24%), no

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Hyperpigmentation using Q-Switched (1064nm and 532nm) Nd:YAG Laser
...Show More Authors

Hyperpigmentation is the increase in the natural color of the skin. The purpose of this study is to evaluate the efficacy and safety of Q-Switched Nd:YAG (1064 & 532 nm) Laser in treatment of skin hyper pigmentation. This study was done in the research clinic of Institute of laser for postgraduate Studies/University of Baghdad from October 2008 to the end of January 2009. After clinical assessment of skin hyperpigmentation color, twenty six patients were divided according to their lesions. Eight Patients with freckles, seven patients with melasma, four patients with tattoo. Cases with tattoo, were subdivided into amateur tattoos two, professional tattoos one, and one traumatic tattoo. Four Patients with post inflammatory hyperpigment

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2004
Journal Name
Iraqi Journal Of Laser
Low Power He:Ne Laser Radiation in Killing Photosensitized Helicobacter pylori in Vitro
...Show More Authors

Four photosensitizers were used to test inhibitory effect of Helicobacter pylori bacteria using
low power helium: neon red laser radiation. Biopsies were collected from 176 patients and H. pylori were
isolated, identified and bacterial suspension was prepared. Samples of this suspension were mixed with
various low concentrations of the test sensitizer. The mixture samples were exposed to different laser
radiation doses. The samples were then inoculated and the inhibition zones were studied and compared
with their analogues of control samples. The most effective sensitizer with optimum concentration and
irradiation dose was determined. Statistical analysis of results was performed. The sensitizers' toluidine
blue and

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 01 2013
Journal Name
Journal Of Physical Science And Application
Photobleaching Influence in Different Phases for Coumarin 307 and Acriflavine Laser Dyes
...Show More Authors

Abstract: Under high-excitation irradiance conditions to induce fluorescence, the dependence of photobleaching of Coumarin 307 (C307) and acriflavine (ACF) laser dyes in liquid and solid phases have been studied. A cw LD laser source of 1 mW and 407 nm wavelength was used as an exciting source. For one hour exposure time, it was found that the solid dye samples suffer photobleaching more than the liquid dye samples. This is because in liquid solutions the dye molecules can circulate during the irradiation, while the photobleaching is a serious problem when the dye is incorporated into solid matrix and cannot circulate.

Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF