Preferred Language
Articles
/
DhYV5osBVTCNdQwCJOS7
Far Infrared Laser Detector Based on Multi-Walled Carbon Nanotubes and Blend of (Polyaniline - Polymethyl Methacrylate) Polymers with Methyl Blue Dye for Photoconductive Applications
...Show More Authors

Infrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector are improved by coating the MWCNTs films with a thin layer of a blend (polyaniline - polymethyl methacrylate) polymer with methylene blue dye. The coated MWCNTs films showed better performances, so this type of coating can be considered as a surface treatment of the detector film, which highly increased the responsivity and specific detectivity of the fabricated IR laser detector-based MWCNTs. The photocurrent response for the coated films was increased about 25 times than that for uncoated films. The results proved the role of the polymer in the enhancement of the performance of the IR photoconductive detectors. Keywords: Carbon nanotubes, Infrared detector, Polyaniline polymer, Polymethyl methacrylate polymer, Methyl Blue dye.

Clarivate Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Biomedical & Pharmacology Journal
Antioxidants and Hepatoprotective Studyof a Purified Bauhinia Variegate Leaves and Flowers against Carbon Tetrachloride-Induced Toxicity in Experimental Rats
...Show More Authors

This study was designed to investigate the hepatoprotective activity and antioxidant enzymes of purified Bauhinia variegate leaves extract and purified flowers extract were administered (200 mg/kg, orally once daily) to reduce the effect of carbon tetrachloride-damage in rat’sliver for three weeks. Thereafter, the levels of some serum biochemical factorssuch as alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase,and the activity of three different antioxidant enzymes (glutathione, superoxide dismutase, and catalase) were investigated.Liver homogenate can used to estimated antioxidant parameters: glutathione, superoxide dismutase and catalase. The purified Bauhinia variegate leaves and purified flowers significantly

... Show More
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Pulse Profile Rule in Laser Heating of Opaque Targets in Air
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account the power temporal variation throughout an incident laser pulse, (i.e. pulse shape, or simply: pulse profile).
Three proposed profiles are employed and results are compared with the square pulse approximation of a constant power.

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 23 2020
Journal Name
Iraqi Journal Of Laser
Fractional CO2 Laser Treatment of Mild Periorbital Wrinkles in Iraqi Patients
...Show More Authors

Background and Objective: Public demand for procedures to rejuvenate photodamaged facial skin have stimulated the use of fractional CO2 laser as a precise and predictable treatment modality. The purpose of this study was to assess the effect of fractional CO2 laser system for reducing periorbital rhytids.

Materials and Methods: twenty seven subjects with mild periocular wrinkles, and photoaged skin of the face were prospectively treated two to three times (according to clinical response) in the periorbital area with a fractional CO2 laser device equipped with a scanning hand piece. Improvements in eyelid wrinkles was evaluated clinically and photographically. Subjects also scored satisfaction and

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystal

... Show More
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic analysis of magnesium-aluminum alloys by laser induced breakdown spectroscopy
...Show More Authors

In this work, the spectra of plasma glow produced by Nd:YAG laser operated at 1.064 μm on Al-Mg alloys with same molar ratio samples in air were analyzed by comparing the atomic lines of aluminum and magnesium with that of strong standard lines. The effect of laser energies on spectral lines, produced by laser ablation, were investigated using optical spectroscopy, the electron density was measured utilizing the Stark broadening of magnesium-aluminum lines and the electron temperature was calculated from the standard Boltzmann plot method. The results that show the electron temperature increases in magnesium and aluminum targets but decreases in magnesium: aluminum alloy target, also show the electron density increase all the aluminum,

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Spot Welding of Dissimilar Metals Using an Automated Nd:YAG Laser System
...Show More Authors

An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.

View Publication Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Evaluation of 940 nm Diode Laser in Esthetic Crown Lengthening
...Show More Authors

Abstract Background: Crown lengthening is a surgical procedure that apically positions the gingival edge and/or removes supporting bone in order to increase the amount of supra gingival tooth structure for restorative or cosmetic purposes.

The objective of the study: The purpose of this study was to evaluate the efficacy of the 940nm diode laser in esthetic crown lengthening surgery through clinical observations, patient questionnaires, clinical photographs, and gingival healing following gingival operations. Material and methods: In this randomized clinical trial, 16 patients (11 females and 5 males) had their crowns surgically lengthened using a diode laser (940 nm) in continuou

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 15 2015
Journal Name
Journal Of Physical Vapor Deposition Science And Technology (jpvdst)
Physical Properties of Nanostructured Silicon Dioxide Prepared by Pulsed-Laser Deposition
...Show More Authors

Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Generation of 629 nm Pulsed Laser Using an Optical Parametric Amplifier
...Show More Authors

The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.

View Publication Preview PDF
Publication Date
Mon Dec 11 2006
Journal Name
Iraqi Journal Of Laser
Treatment of Bilateral Vocal Cord Paralysis by 810 nm Diode Laser
...Show More Authors

This is prospective study began in Jan. 2003 and concluded in April 2004, was undertaken to examine the benefits of 810 nm diode laser in treatment of four patient with bilateral vocal cord paralysis also to compare the results with conventional treatment Material and methods: 810 nm diode laser 15 watts was used in these cases under general anesthesia, and induction of anesthetic drug done through tracheostomy tube in all patients. All patients were decanulated “Tracheostomy tube removed”, the voice of all preserved within normal. Laser surgery in this case has more benefit and advantage than conventional methods even if the patient need more than on session of laser operation because of high success rate, less complication and easy

... Show More
View Publication Preview PDF