Preferred Language
Articles
/
DhYV5osBVTCNdQwCJOS7
Far Infrared Laser Detector Based on Multi-Walled Carbon Nanotubes and Blend of (Polyaniline - Polymethyl Methacrylate) Polymers with Methyl Blue Dye for Photoconductive Applications
...Show More Authors

Infrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector are improved by coating the MWCNTs films with a thin layer of a blend (polyaniline - polymethyl methacrylate) polymer with methylene blue dye. The coated MWCNTs films showed better performances, so this type of coating can be considered as a surface treatment of the detector film, which highly increased the responsivity and specific detectivity of the fabricated IR laser detector-based MWCNTs. The photocurrent response for the coated films was increased about 25 times than that for uncoated films. The results proved the role of the polymer in the enhancement of the performance of the IR photoconductive detectors. Keywords: Carbon nanotubes, Infrared detector, Polyaniline polymer, Polymethyl methacrylate polymer, Methyl Blue dye.

Clarivate Crossref
View Publication
Publication Date
Sat Apr 01 2023
Journal Name
The Ocular Surface
Detecting dry eye from ocular surface videos based on deep learning
...Show More Authors

View Publication
Scopus (21)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sat Jun 15 2024
Journal Name
Iraqi Journal Of Laser
Estimation of mean photon number based on single photon detection of weak coherent pulses
...Show More Authors

The demand for single photon sources in quantum key distribution (QKD) systems has necessitated the use of weak coherent pulses (WCPs) characterized by a Poissonian distribution. Ensuring security against eavesdropping attacks requires keeping the mean photon number (µ) small and known to legitimate partners. However, accurately determining µ poses challenges due to discrepancies between theoretical calculations and practical implementation. This paper introduces two experiments. The first experiment involves theoretical calculations of µ using several filters to generate the WCPs. The second experiment utilizes a variable attenuator to generate the WCPs, and the value of µ was estimated from the photons detected by the BB

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 30 2024
Journal Name
Iraqi Journal Of Science
Corrosion Behavior of Titanium in the Presence of Some Drugs Based on Amino Groups
...Show More Authors

This study evaluated the effect of two different types of amino group-containing pharmacological inhibitors on titanium corrosion under acidic conditions. The first inhibitor examined was the antibiotic trimethoprim. The second inhibitor studied was the nonsteroidal anti-inflammatory drug voltaren. The results showed that titanium had a high corrosion current in the absence of a corrosion inhibitor, however, trimethoprim notably enhanced corrosion resistance and protection percentages of titanium (%IE) at higher concentrations by adhering to the metal surface, as evidenced by improved protection percentages. Furthermore, the results showed that as Voltaren concentration was increased, both corrosion resistance and inhibition efficie

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Sat Sep 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Implementation of Transmitter Zigbee System based on Wireless Sensor Network of IEEE 802.15.4 Standard
...Show More Authors

Abstract

 

Zigbee is considered to be one of the wireless sensor networks (WSNs) designed for short-range communications applications. It follows IEEE 802.15.4 specifications that aim to design networks with lowest cost and power consuming in addition to the minimum possible data rate. In this paper, a transmitter Zigbee system is designed based on PHY layer specifications of this standard. The modulation technique applied in this design is the offset quadrature phase shift keying (OQPSK) with half sine pulse-shaping for achieving a minimum possible amount of phase transitions. In addition, the applied spreading technique is direct sequence spread spectrum (DSSS) technique, which has

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Oct 31 2023
Journal Name
College Of Islamic Sciences
The fatwa based on the statement of Zafar In the Hanafi school of thought
...Show More Authors

Each school of Islamic jurisprudence has principles and rules upon which the diligent work in these schools is based. This is due to the view of sanctification of these rulings, as they are divine rulings. Therefore, the goal is to reach a ruling that represents the intent of the legislator as much as possible.
Hence, these schools of thought established rules for issuing fatwas with the intention of restricting the performance of a fatwa to the hands of those who are qualified for it and have met its conditions, so they gave priority to the most knowledgeable person over others to perform the fatwa. In the Hanafi school of thought, for example, the saying of Imam Abu Hanifa (may God have mercy on him) is given precedence over others,

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 11 2022
Journal Name
Journal Of Petroleum Research And Studies
Distribution of Petrophysical Properties Based on Conceptual Facies Model, Mishrif Reservoir/South of Iraq
...Show More Authors

A 3D geological model is an essential step to reveal reservoir heterogeneity and reservoir properties distribution. In the present study, a three-dimensional geological model for the Mishrif reservoir was built based on data obtained from seven wells and core data. The methodology includes building a 3D grid and populating it with petrophysical properties such as (facies, porosity, water saturation, and net to gross ratio). The structural model was built based on a base contour map obtained from 2D seismic interpretation along with well tops from seven wells. A simple grid method was used to build the structural framework with 234x278x91 grid cells in the X, Y, and Z directions, respectively, with lengths equal to 150 meters. The to

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Al-khwarizmi Engineering Journal
Adsorption of Indigo Carmen Dye by Using Corn Leaves as Natural Adsorbent Material
...Show More Authors

    In this paper, the ability of using corn leaves as low-cost natural biowaste adsorbent material for the removal of Indigo Carmen (IC) dye was studied. Batch mode system was used to study several parameters such as, contact time (4 days), concentration of dye (10-50) ppm, adsorbent dosage (0.05-0.25) gram, pH (2-12) and temperature (30-60) oC. The corn leaf was characterized by Fourier-transform infrared spectroscopy device before and after the adsorption process of the IC dye and scanning electron microscope device was used to find the morphology of the adsorbent material. The experimental data was imputing with several isotherms where it fits with Freundlich (R2 = 0.9937) and followed pseudo second order kinetic. The hi

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Decolorizing of Malachite Green Dye by Adsorption Using Corn Leaves as Adsorbent Material
...Show More Authors

This paper presents the ability to use cheap adsorbent (corn leaf) for the removal of Malachite Green (MG) dye from its aqueous solution. A batch mode was used to study several factors, dye concentration (50-150) ppm, adsorbent dosage (0.5-2.5) g/L, contact time (1-4) day, pH (2-10), and temperature (30-60)   The results indicated that the removal efficiency increases with the increase of adsorbent dosage and contact time, while inversely proportional to the increase in pH and temperature. An SEM device characterized the adsorbent corn leaves. The adsorption's resulting data were in agreement with Freundlich isotherm according to the regression analysis, and the kinetics data followed pseudo-first-order kinetic with a correlation

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Al-khwarizmi Engineering Journal
Adsorption of Indigo Carmen Dye by Using Corn Leaves as Natural Adsorbent Material
...Show More Authors

   

In this paper, the ability of using corn leaves as low-cost natural biowaste adsorbent material for the removal of Indigo Carmen (IC) dye was studied. Batch mode system was used to study several parameters such as, contact time (4 days), concentration of dye (10-50) ppm, adsorbent dosage (0.05-0.25) gram, pH (2-12) and temperature (30-60) oC. The corn leaf was characterized by Fourier-transform infrared spectroscopy device before and after the adsorption process of the IC dye and scanning electron microscope device was used to find the morphology of the adsorbent material. The experimental data was imputing with several isotherms where it fits with Freundlich (R2 = 0.9

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Tue May 05 2015
Journal Name
International Journal Of Research In Pharmacy And Chemistry
NEW APPROACH FOR DETERMINATION OF MEBEVERINE BY QUENCHED FLUORESCENCE OF ANALYTICALLY INTERESTED SPECIES USING CONTINUOUS FLOW INJECTION LASER DIODE FLUORIMETER ANALYSER
...Show More Authors

The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit

... Show More
View Publication