Preferred Language
Articles
/
DUKPCpoBMeyNPGM3D7xx
Hematological Parameters in Liver Metastasis: A Comprehensive Clinical Evaluation for Early Detection in Iraqi Patients
...Show More Authors

Background: Liver metastasis significantly complicates cancer prognosis, yet easily accessible markers for its early detection and monitoring remain crucial. This study aimed to comprehensively evaluate key hematological parameters as potential indicators for liver metastasis in Iraqi patients. Methods: We conducted a cross-sectional study comparing hematological profiles between 90 patients (presumably with liver metastasis) and 30 healthy controls. White Blood Cell (WBC) count, Lymphocyte percentage, Neutrophil percentage, and Neutrophil-to-Lymphocyte Ratio (NLR) were analyzed. Given non-normal data distributions (confirmed by the Shapiro-Wilk test), group comparisons were performed using the non-parametric Mann-Whitney U test. Results: Statistically significant differences were observed across all investigated hematological parameters between the patient and control groups. Patients exhibited elevated WBC counts (p<0.0001) and neutrophil percentages (p=0.0310), indicative of systemic inflammation. Conversely, a highly reduction in lymphocyte percentage (p<0.0001) was noted in the patient group, suggesting relative lymphopenia and a potential shift towards innate over adaptive immune responses. Most notably, the Neutrophil-to-Lymphocyte Ratio (NLR) was significantly higher in patients (p<0.0001), reflecting a pronounced systemic inflammatory state and immune imbalance associated with advanced disease. Conclusion: This study demonstrates a robust association between altered hematological profiles and disease status in patients, consistent with the immune dysregulation characteristic of liver metastasis. These parameters may serve as valuable indicators for early diagnosis and risk stratification in patients with liver metastasis. Their clinical utility could enhance treatment decision-making and patient monitoring in routine practice, and cost-effective and non-invasive markers for early detection, risk stratification, and therapeutic monitoring in Iraqi patients with liver metastasis. Further research is warranted to validate their role in specific clinical algorithms.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 28 2021
Journal Name
International Journal Of Intelligent Engineering And Systems
Intelligent System for Parasitized Malaria Infection Detection Using Local Descriptors
...Show More Authors

Malaria is a curative disease, with therapeutics available for patients, such as drugs that can prevent future malaria infections in countries vulnerable to malaria. Though, there is no effective malaria vaccine until now, although it is an interesting research area in medicine. Local descriptors of blood smear image are exploited in this paper to solve parasitized malaria infection detection problem. Swarm intelligence is used to separate the red blood cells from the background of the blood slide image in adaptive manner. After that, the effective corner points are detected and localized using Harris corner detection method. Two types of local descriptors are generated from the local regions of the effective corners which are Gabor based f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Al-mansoor College
An Improvement to Face Detection Algorithm for Non-Frontal Faces
...Show More Authors

Publication Date
Sat Apr 05 2025
Journal Name
2025 Ieee 4th International Conference On Computing And Machine Intelligence (icmi)
From Pixels to Diagnosis: AI-Powered CNN for Pneumonia Detection
...Show More Authors

View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Journal Of The College Of Education For Women
Minimum Spanning Tree Algorithm for Skin Cancer Image Object Detection
...Show More Authors

This paper proposes a new method Object Detection in Skin Cancer Image, the minimum
spanning tree Detection descriptor (MST). This ObjectDetection descriptor builds on the
structure of the minimum spanning tree constructed on the targettraining set of Skin Cancer
Images only. The Skin Cancer Image Detection of test objects relies on their distances to the
closest edge of thattree. Our experimentsshow that the Minimum Spanning Tree (MST) performs
especially well in case of Fogginessimage problems and in highNoisespaces for Skin Cancer
Image.
The proposed method of Object Detection Skin Cancer Image wasimplemented and tested on
different Skin Cancer Images. We obtained very good results . The experiment showed that

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Practical Study for the Properties of Hueckel Edge Detection Operator
...Show More Authors

View Publication
Crossref (4)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
DNA Encoding and STR Extraction for Anomaly Intrusion Detection Systems
...Show More Authors

View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Neuroscience Informatics
Epileptic EEG activity detection for children using entropy-based biomarkers
...Show More Authors

View Publication
Scopus (22)
Crossref (15)
Scopus Crossref
Publication Date
Fri Nov 15 2024
Journal Name
Scientific Reports
Ag@WO3 core–shell nanocomposite for wide range photo detection
...Show More Authors

This study successfully synthesized high-performance photodetectors based on Ag-WO3 core–shell heterostructures using a simple and economical two-step pulsed laser ablation in water method and has investigated the electrical characteristics of the Ag@WO3 nanocomposite heterojunction. The Hall effect tests indicate that the synthesized Ag@WO3 exhibits n-type conduction with a Hall mobility of 1.25 × 103 cm2V-1S-1. Dark current–voltage properties indicated that the created heterojunctions displayed rectification capabilities, with the highest rectification factor of around 1.71 seen at a 5 V bias. A photodetector’s responsivity reveals the existence of two response peaks, which are situated in the ultraviolet and visible region. The ph

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EVALUATION OF ELECTRONIC TRADING AND CENTRAL DEPOSITERY IN THE IRAQ STOCK EXCHANGE FOR THE PERIOS (2008- 2018): EVALUATION OF ELECTRONIC TRADING AND CENTRAL DEPOSITERY IN THE IRAQ STOCK EXCHANGE FOR THE PERIOS (2008- 2018)
...Show More Authors

The rapid developmemt of information technology and its use in all fields has a bositive influence on all fields , and financial markets have a share of this development through the use of an electronic trading system to settle transactions and enhance transparency and disclosure in all activities of these markets and stimulate their performance .

It is worth nothing that these revolutions remove the necessity for nonstop connection with persons through the internet or phone networks , novel knowledge decreases the charges of structure original transaction system and reducing the fences of new participants entry .

The development in transportations expertise allows for quicker or

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2020
Journal Name
Medico-legal Update,
Histological and enzyme histochemical changes of liver induced by the action of maxxthor insecticide in male albino rats
...Show More Authors

The present study aimed to investigate the histological, enzyme histochemical changes and liver function effects of Maxxthor insecticide on albino rats in liver. The experiment included 20 rat which were divided into four groups, the first group 5 rats were considered the control animals and the others were divided equally into three groups with a dose of 0.01, 0.1and 1 mg / kg of body weight, respectively for a period 40 days. The animals given each 48 hours via oral route Maxxthor by tube dosage after dissolved with distilled water. Microscopic examination of liver showed inflammatory cell aggregation around vessels, congestion and dilation of sinusoids hepatocytes hypertrophy with severs inflammatory cells infiltration, kupffer cells pro

... Show More
Preview PDF
Scopus (1)
Scopus