Preferred Language
Articles
/
CxcmT48BVTCNdQwCnWuH
Analysis of laser induced breakdown spectra for distinguish between healthy and carious teeth
...Show More Authors

Dielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadening method was used to calculate the electron density (ne). © 2024 American Institute of Physics Inc.. All rights reserved.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Feb 05 2019
Journal Name
Journal Of The College Of Education For Women
Women of drama between theoretical and practical
...Show More Authors

Greek theatre and roman theatre don’t let for woman with working in the theatre such as writer , directing and acting theatre , so appear term women theatre in past sixty central because the woman feeling with iniquitousness in your life , so this search included several sections that include money parts . Part one is term theatre women. Part two causes show the women theatre. Part three jenouse women in writer, direction, and action in the world. Part four jenouse women in the Arab theatre. Part fife Iraqi woman jenouse in the theatre. Section tow includes analyses for once performance Iraqi theatre that include several women. This performance from editor and direction by kaseem – Muhammad, assistant in the direction montaha – rah

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD
...Show More Authors

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Wed Jun 15 2022
Journal Name
Malaysian Journal Of Science
STUDY THE RELATIONSHIP BETWEEN BREMSSTRAHLUNG DOSE RATE AND THE ENERGY OF BETA RAY FOR DIFFERENT TYPES OF SHIELD
...Show More Authors

The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each

... Show More
Preview PDF
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Effectiveness of 980nm diode Laser in reduction the diameters of exposed dentinal tubules for hypersensitive tooth
...Show More Authors

Abstracts:

Background: The oral cavity is a complex environment, both structurally and functionally, the hard and soft tissues are in close a proximity. Oral tissues subjected to wear throughout the life, that threatened the vitality of the pulp or increase the sensitivity of dentinal tubules. One of the common dental problems is loss of enamel or cementum, which stimulate the nerve ending in or near the pulp and manifested as pain sensation. Aim of the study: This study had done to evaluate the effects of 980nm diode Laser in diameters reduction of exposed dentinal tubules analyze the results and morphological changes of irradiated dentine surface by FE-SEM (field emission scann

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of the competitiveness for commercial banks in Iraq for a period of 2004 – 2012
...Show More Authors

This study was conducted on a sample of commercial banks in Iraq, chosen according number of considerations for twenty banks, contained two public banks and eighteen private banks.                                                                                             &

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
Potential Benefits of Ethanol extract of Anredera cordifolia for Antiobesity of High Fat diet-Induced Obesity in White Male Rat Wistar
...Show More Authors

Obesity-related deaths continue to rise, and thus losing weight in overweight and obese patients is critical to prevent complications. Anredera cordifolia (Ten,) Steenis, species of succulent plant of the genus Basellaceae, is widely used in herbal medicine to decrease body weight. This study evaluated the potential benefits of Anredera cordifolia ethanol extract to reduce body weight in high-fat diet-induced obesity rat model. This was an experimental with post-test only control group design study involving 36 obese rats. They were divided into two groups: three control groups (K1, K2, K3) and three treatment groups (P1, P2, P3). All the groups were induced with high-fat diet, except K1 control group that received a standard di

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Feb 29 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Laser Cutting Methods on Hole Deviation and Surface Integrity
...Show More Authors

In the present work usedNd:YAG laser systems of different output characteristic were employed to study the drilling process of material used in scientific and industrial fields. This material include Manganese hard steel. Our study went into the affecting parameters in drilling of Manganese hard steel by laser. Drilling process is achieved through material absorption of part of the incident laser beam. It is the resultant of interfering both, laser beam and material properties and the focusing conditions of the beam. The results as shown that the increase in the laser pulse energy over the used level has raised the hole diameter, depth and increased the hole taper. In addition to that a hole taper was affected by the laser energy, the fo

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitat

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Effect of Laser Energy and Repetition Rate on Holmium Plasma Emission
...Show More Authors

The holmium plasma induced by a 1064-nmQ-switched Nd:YAG laser in air was investigated. This work was done theoretically and experimentally.  Cowan code was used to get the emission spectra for different transition of the holmium target. In the experimental work, the evolution of the plasma was studied by acquiring spectral images at different laser pulse energies (600,650,700, 750, and 800 mJ). The repetition rates of (1Hz and 10Hz) in the UV region (200-400 nm). The results indicate that, the emission line intensities increase with increasing of the laser pulse energy and repetition rate. The strongest emission spectra appeared when the laser pulse energy is 800mJ and 10 Hz repetition rate at λ= 345.64nm, with the maximum intensi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Journal Of Materials Research And Technology
The effect of laser pulse energy on ZnO nanoparticles formation by liquid phase pulsed laser ablation
...Show More Authors

Zinc Oxide nanoparticles were prepared using pulsed laser ablation process from a pure zinc metal placed inside a liquid environment. The latter is composed of acetyltrimethylammonium bromide (CTAB) of 10−3 molarity and distilled water. A Ti:Sapphire laser of 800 nm wavelength, 1 kHz pulse repetition rate, 130 fs pulse duration is used at three values of pulse energies of 0.05 mJ, 1.11 mJ and 1.15 mJ. The evaluation of the optical properties for the obtained suspension was applied through ultraviolet–visible absorption spectroscopy test (UV/VIS). The result showed peak wavelengths at 210 nm, 211 nm and 213 nm for the three used pulse energies 0.05 mJ, 1.11 mJ and 1.15 mJ respectively. This indicates a blue shift,

... Show More
View Publication Preview PDF
Scopus (56)
Crossref (53)
Scopus Clarivate Crossref