Invasomes are newly developed types of nanovesicles. A vesicular drug delivery system is considered one of the approaches for transdermal delivery to enhance permeation and improve drug bioavailability. Ondansetron is a serotonin receptor antagonist used for treating vomiting associated with different clinical cases. The study aimed to prepare invasomal dispersions for improving permeation of ondansetron across the skin with a controlled release pattern. Twenty-seven formulas of ondansetron-loaded invasomes were prepared by a modified mechanical dispersion method. These formulas were optimized by studying the effect of variables on entrapment efficiency. Vesicle size, polydispersity, zeta potential, in-vitro release and ex-vivo permeation studies were done for the optimized formulas. The selected formula was )F25( had )88.24%±0.04 (entrapment, (317.7 nm) vesicle size, (0.29) polydispersity, and (-31.5mV) zeta potential. In-vitro release study showed That (F25) had 75% release after (12) hrs., and dissolution followed the Korsmeyer-Peppas model with anomalous diffusion. Ex-vivo permeation study showed steady-state flux was 340.2 µg/cm2.hr with no lag time using rat skin tissue. A transmission electron microscope was done to visualize the selected formula. Invasomes are considered promising drug delivery systems for transdermal delivery of ondansetron, ensuring efficient permeation with a sustained release pattern.
Objective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show MoreIn this research a local adsorbent was prepared from waste tires using two-step pyrolysis method. In the carbonization process, nitrogen gas flow rate was 0.2L/min at carbonization temperature of 500ºC for 1h. The char products were then preceded to the activation process at 850°C under carbon dioxide (CO2) activation flow rate of 0.6L/min for 3h. The activation method produced local adsorbent material with a surface area and total pore volume as high as 118.59m2 /g and 0.1467cm3/g, respectively. The produced . local adsorbent (activated carbon) was used for adsorption of lead from aqueous solution. The continuous fixed bed column experiments were conducted. The adsorption capacity performance of prepared activated carbons in this work
... Show MoreThe aim of this study was to know ( the impact of education differentiated strategy to modify the alternative developments of geographical concepts when students first grade average) .
To achieve the goal of this study , researcher relied on the experimental design of a partial set , the design is ( the experimental group with a control group of post-test ).
&nbs
... Show MoreDialysis is a stressful process and follows various psychological and social problems, which can lead to psychological disturbances. Patients on dialysis experience psychological distress, and the reduction of stress in patients provides psychological resources to cope with their physical condition. The study aimed to evaluate the effect of deep-breathing exercise training on the level of stress among maintenance hemodialysis patients.
This study is a randomized
This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol
... Show MoreThis paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation
... Show MoreIntravascular embolisation of foreign bodies (FB) is a rare, serious complication that may occur during central venous line insertion. A 39-yearold male in a critical condition presented to casualty department with a through-and-through chest gunshot wound. Chest X-ray showed left haemothorax; an urgent chest tube was introduced and central venous access was introduced via the right femoral vein. The guided wire used in the procedure was unintentionally pushed to reach the right ventricular apex. Echocardiography confirmed FB location. Once stabilised, the patient was referred to Iraqi Centre of Cardiac Diseases, where transcatheter retrieval was performed. To stabilise the FB, a 6F pigtail catheter was used to create a U-shaped loop in the
... Show MoreSolid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm2), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on