Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratchet from the dental implant kit and ISQ values generated from the Osstell device. Results: Twenty patients (13 female and 7 male) with an age range of 25-65 years received twenty immediate dental implants. The insertion torque value ranged from 15 to 50 N/cm with a mean of 28 N/cm. At the same time, the ISQ values ranged between 50 and 80 ISQ values, with a mean of 63 ISQ values. The results showed a statistically significant positive correlation between the insertion torque of the dental implant measured by torque rachet and ISQ values checked with Osstell. Conclusion: The insertion torque can be used as a reliable method to estimate the primary stability of the immediately inserted dental implants in the maxillary non-molar sites comparable to the Osstell device ISQ values. In addition, torque ratchet is readily available in the dental implant kit at no additional cost, making it a valuable choice over the Osstell device.
Aims: This study aims to compare patients’ complaints and problems of wearing complete dentures.
Methodology: The sample included 40 Iraqi patients who are wearing complete dentures from about five years ago. They
were selected randomly with a age range between (55–65) years. The questions asked to the patients were listed according
to the recent classification of post-insertion problems.
Result: The results showed that the percentage of patient's complaint from adaptation problems (62.1%) was higher than
looseness problems (61.3%) and discomfort problems (39.3%) as followed.
Recommendation: Dentists need thorough knowledge of anatomy, physiology, pathology and psychology. The assessing
of the psyche and emotions
The topic of this research deals with an analytical study of the nature of the visual sent by the sculptural monument of the person of Christ around the world, the nature of this monument, the manner of its embodiment, the mechanism of reception for each of the societies that this monument addressed to them, how it was reflected on them, how it was reflected on them, and whether these works are related to their culture or not, I discussed this study All this, and the researcher has established theoretical research axes for the research according to the desired goal of this study, which is the definition of the mechanism of visual discourse of statues of Christ around the world and were as follows: (The first axis: the discourse and visua
... Show MoreA descriptive evaluation study is conducted on primary health care centers in Baghdad City in order to
evaluate the organization structure as component of quality improvement of maternal and child health promotion
from April 10th 2012 to May20th 2013. A total of (22) primary health care centers. Study instrument was
comprised of three questionnaires and overall items included in these questionnaire were (65) items. Data are
collected through the utilization of the developed questionnaire and the interview technique as means of data
collection. Data are analyzed through the application of descriptive statistical data analysis methods which
includes the measurement of the frequencies, percentages, and computation of mean
Abstract
We produced a study in Estimation for Reliability of the Exponential distribution based on the Bayesian approach. These estimates are derived using Bayesian approaches. In the Bayesian approach, the parameter of the Exponential distribution is assumed to be random variable .we derived bayes estimators of reliability under four types when the prior distribution for the scale parameter of the Exponential distribution is: Inverse Chi-squar
... Show MoreFlexible molecular docking is a computational method of structure-based drug design to evaluate binding interactions between receptor and ligand and identify the ligand conformation within the receptor pocket. Currently, various molecular docking programs are extensively applied; therefore, realizing accuracy and performance of the various docking programs could have a significant value. In this comparative study, the performance and accuracy of three widely used non-commercial docking software (AutoDock Vina, 1-Click Docking, and UCSF DOCK) was evaluated through investigations of the predicted binding affinity and binding conformation of the same set of small molecules (HIV-1 protease inhibitors) and a protein target HIV-1 protease enzy
... Show MoreThe research specified with study the relation between the market share for the sample research banks and the amount of the achieved revenues from the investment, where the dominated belief that there potentiality enhancing the revenue on investment with the increase of the banks shares in their markets after their success in achieving rates of successive growth in their sales of sales and to a suitable achieve market coverage for their products and they have dissemination and suitable promotion activity, the market share represented the competition for the banks, and the markets pay attention to the market share as a strategic objective and to maintain them also increasi
... Show More