The current study was conducted to demonstrate the effects of air pollution on different biochemical parameters inCitrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected tocollect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and closeto the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonalsamples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters totalchlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugarcontent, proline, electrical conductivity, cadmium and lead. The results of Citrus plant showed high chlorophyllconcentration and ascorbic acid content in private generator site reached to (10.620 mg/g and 0.403 mg/g)respectively. While relative water content recorded high concentration (57.563 %) at Al-Jadriya site. pH recordedhigh value (6.358) at Al-Doura site. In addition, values of APTI of the Citrus plant were calculated to determinethe sensitivity of the plant to air pollution. Highest value of APTI (6.23) was recorded at Al-Jadriya site, whilelowest value of APTI (5.03) was recorded at Al-Andlous site. The results of present study revealed that Citrusaurantium is sensitive to air pollution and can be used as bio-indicator under pollution stress. (PDF) Use Citrus aurantium plant as bio-indicator of air pollution in Baghdad city. Available from: https://www.researchgate.net/publication/379807094_Use_Citrus_aurantium_plant_as_bio-indicator_of_air_pollution_in_Baghdad_city [accessed May 07 2024].
Collapsing building structures during recent earthquakes, especially in Northern and Eastern Kurdistan, including the 2003 earthquake in Cewlig; the 2011 earthquake in Van; and the 2017 earthquake near Halabja province, has raised several concerns about the safety of pre-seismic code buildings and emergency facilities in Erbil city. The seismic vulnerability assessment of the hospital buildings as emergency facilities is one of the necessities which have a critical role in the recovery period following earthquakes. This research aims to study in detail and to extend the present knowledge about the seismic vulnerability of the Rizgary public hospital building in Erbil city, which was constructed before releasing the seism
... Show MoreThe earth-air heat exchanger (EHX) has a promising potential to passively save the energy consumption of traditional air conditioning systems while maintaining a high degree of indoor comfort. The use of EHX systems for air conditioning in commercial and industrial settings offers several environmental benefits and is capable of operating in both standalone and hybrid modes. This study tests the performance and effectiveness of an EHX design in a sandy soil area in Baghdad, Iraq. The area has a climate of the subtropical semi-humid type. Ambient air temperatures and soil temperatures were recorded throughout the months of 2021. During the months of January and June, the temperatures of the inlet and outflow air at varying air veloci
... Show MoreThe air flow pattern in a co-current pilot plant spray dryer fitted with a rotary disk atomizer was determined experimentally and modelled numerically using Computational Fluid Dynamics (CFD) (ANSYS Fluent ) software. The CFD simulation used a three dimensions system, Reynolds-Average Navier-Stokes equations (RANS), closed via the RNG k −ε turbulence model. Measurements were carried out at a rotation of the atomizer (3000 rpm) and when there is no rotation using a drying air at 25 oC and air velocity at the inlet of 5 m/s without swirl. The air flow pattern was predicted experimentally using cotton tufts and digital anemometer. The CFD simulation predicted a downward central flowing air core surrounded by a slow
... Show MoreIn this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show MoreThe objective of the present paper is to examine the effect of Recycled Asphalt Pavement (RAP) on marshall properties and indirect tensile strength of HMA through experimental investigation. A mixture with 0% RAP was used as a control mix to evaluate the properties of mixes with 5%, 10%, and 15% RAP. One type of RAP was brought from Bab Al-moadam’s road in Baghdad for this purpose. The experimental testing program included Marshall and Indirect Tensile Strength tests. The results indicated that the bulk density, flow and VFA increase with the increasing of the percentage of RAP, while increasing in RAP results decreases in VTM and VMA values. Furthermore, the stability is changed from 10.1 kN for the control mix to12, 13.6 and 11.7 kN
... Show MoreValue Engineering is an analytical study on projects or services using a specific procedure and a multidisciplinary working group, works for the identification and classification of the project functions; either for a better perfuming of these functions or to lessen the total project cost or the two together. Value Engineering main aim is on finding innovative alternatives, without effecting the basic requirements of the project, its methodology based on the functional balancing between the three elements of production "performance, quality and cost". This methodology based on the "functional analysis", had shown high possibilities in solving any problem facing the production procedure , achieve better investment for available re
... Show MoreAir pollution refers to the release of pollutants into the air that are detrimental to human health and the planet as a whole.In this research, the air pollutants concentration measurements such as Total Suspended Particles(TSP), Carbon Monoxides(CO),Carbon Dioxide (CO2) and meteorological parameters including temperature (T), relative humidity (RH) and wind speed & direction were conducted in Baghdad city by several stations measuring numbered (22) stations located in different regions, and were classified into (industrial, commercial and residential) stations. Using Arc-GIS program ( spatial Analyses), different maps have been prepared for the distribution of different pollutant