Preferred Language
Articles
/
CRcG0ZEBVTCNdQwCwpt_
Utilizing the Controlled Hydropower System to Harness the Collected Water in Drainage System for Power Generation
...Show More Authors

The variety of clean energy sources has risen, involving many resources, although their fundamental principles remain consistent in terms of energy generation and pollution reduction. The using of hydropower system for energy production also has a dynamic impact in which it utilizes to harness the water for the purpose of energy production. As it is important to overcome the problem of accidents in the highway and rural areas in the case of server rainfall and flood by implementation a smart system that used for energy production. This paper aims to develop a controlled hydropower system installed in the drainage sinks allocated in highway roads used for producing. The proposed system consists of storage unit represented by pipes used for the purpose of water collecting, it's coupled with Francis's turbine and DC generator. A controlled unit is utilized to control the discharging process of collected water in which float and rotation sensors are connected to identify the water level and generator movement to allot the solenoid valve for the purpose of water collecting and discharging based on assigned point. According to the elementary findings, a power output of 20 watts is observed for every 10-second interval. In the event of a significant flood occurrence, the system will continue to operate, resulting in an output energy accumulation of 4 KWATT per hour. The quantity of energy available is adequate to supply electricity for a duration of one hour to direct current light-emitting diode (DC-LED) devices, or it can alternatively be stored in batteries.

Scopus Crossref
View Publication
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Implementation of Power System Stabilizer Based on Conventional and Fuzzy Logic Controllers
...Show More Authors

To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. A suitable PSS model was selected considering the low frequencies oscillation in the inter-area mode based on conventional PSS and Fuzzy Logic Controller. Two types of (FIS) Mamdani and suggeno were considered in this paper. The software of the methods was executed using MATLAB R2015a package.

 

 

View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Mar 31 2026
Journal Name
Polymers For Advanced Technologies
Utilizing the Potential of Polyvinylidene Fluoride in Developing Durable Superhydrophobic and Antibacterial Nanocomposite Coatings for Oil/Water Separation
...Show More Authors
ABSTRACT<p> The increasing demand for durable and multifunctional separation materials necessitates polymer‐based coatings that combine mechanical robustness with high selectivity. This study aims to develop antibacterial oil/water separation systems that effectively address challenges posed by microorganisms, which can decrease filter effectiveness and impact overall separation efficiency. Metal meshes were coated with titanium dioxide (TiO <sub>2</sub> ), octadecanethiol (ODT), and polyvinylidene fluoride (PVDF) via spray coating using four formulations: TiO <sub>2</sub> </p> ... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2010
Journal Name
Int. J. Adv. Comp. Techn.
Adding PC Connectivity to the MTS-88 Microcomputer Teaching System
...Show More Authors

The MTS-88. c trainer is a training system targeting students in the microprocessors course. It has a built in single-line assembler allowing the users to enter programs in assembly. It has the problem that long programs cannot be traced and tested efficiently. A simple error may cause all the code to be erased and the system to stop responding. Also, this system lacks the ability to be connected to the PC. The aim of this work is to modify the system to make it possible to be connected to the PC through the parallel port. This gives the capability to download long programs to the system after being developed in the PC. The 8255 Programmable Peripheral Interface available in the teaching system is interfaced to the parallel port and used as

... Show More
Publication Date
Sat Jul 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
The Effect of Dry Farming and Water Stress under Subsurface Drip Irrigation System on Water and Rice Productivity
...Show More Authors
Abstract<p>A field experiment was carried out during the 2020 season at the College of Agricultural Engineering/ University of Baghdad, Al-Jadriya to evaluate the effect of dry farming when applying water stress under the subsurface drip irrigation system on water productivity and rice yield. The experiment was conducted with three levels of irrigation water stress when 10, 20 and 40% of the available water was depleted and in three dimensions between drip lines 10, 15 and 20 cm. The experiment was designed according to a randomized complete block design, according to the split plot design, with three replications. Determine the depth of irrigation water depending on the moisture depletion of th</p> ... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Design and Implementation of an Automatic Control for Two Axis Tracking System for Applications of Concentrated Solar Thermal Power
...Show More Authors

The present work presents design and implementation of an automated two-axis solar tracking system using local materials with minimum cost, light weight and reliable structure. The tracking system consists of two parts, mechanical units (fixed and moving parts) and control units (four LDR sensors and Arduino UNO microcontroller to control two DC servomotors). The tracking system was fitted and assembled together with a parabolic trough solar concentrator (PTSC) system to move it according to information come from the sensors so as to keep the PTSC always perpendicular to sun rays. The experimental tests have been done on the PTSC system to investigate its thermal performance in two cases, with tracking system (case 1) and without trackin

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Oct 20 2018
Journal Name
Journal Of Economics And Administrative Sciences
Measuring the performance of government units according to the government accounting system
...Show More Authors

Abstract

This study aims at clarifying the current performance appraisal system in government units and the extent to which they contribute to the development of the performance of these units by evaluating and measuring the performance of these units on an ongoing basis to subject their services to an assessment and measurement process in order to improve the efficiency of these units to reach their objectives efficiently and effectively. (Iraqi hospitals) by trying to determine the possibility of the government accounting system in the process of evaluating performance, through the comparison of financial performance for successive years and different hospitals using the financial and non-financial model of the evaluati

... Show More
View Publication
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Minar International Journal Of Applied Sciences And Technology
INVESTIGATION OF THE DENSITY OF STATE PROBABILITY FOR FE METAL CONTACT TO TIO2 SEMICONDUCTOR SYSTEM
...Show More Authors

In this paper, the density of state (DOS) at Fe metal contact to Titanium dioxide semiconductor (TiO2) has been studied and investigated using quantum consideration approaches. The study and calculations of (DOS) depended on the orientation and driving energies. was a function of TiO2 and Fe materials' refractive index and dielectric constant. Attention has focused on the effect of on the characteristic of (DOS), which increased with the increasing of refractive index and dielectric constant of Fe metal and vice versa. The results of (DOS) and its relation with and values of system have been discussed. As for contact system is increased, (DOS) values increased at first, but the relation is disturbed later and transforms into an inve

... Show More
View Publication
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
An Investigation into Thermal Performance of Mist Water System and The Related Consumption Energy
...Show More Authors

Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
The Mutagenic Effect of water Extracts of Malva parviflora by Bacterial System (part II )
...Show More Authors

This study was carried out in order to determine the toxic, mutagenic and antimutagenic effects for Mallow (Malva parviflora) in comparison to its mutagenic effect of Ultraviolet (UV) because it is consider physical mutagen by using parameters for the extract pri , with , post UV exposure by using bacterial system (G-system). The used system consisted of three isolates G3 Bacillus spp., G12 Arthrobacter spp. and G27 Brevibacterium spp.. The study depended on recording survival fraction (Sx) for studying the effects and induction of Streptomycin and Refampicin resistance mutants as a genetic markers.Water Extract was prepared from fresh and dry mallow leaves, stems, flowers and roots, in optimum concentration equal to (125µg/ml) which is

... Show More
View Publication Preview PDF
Crossref (1)
Crossref