The solvent free oxidation of benzyl alcohol was conducted employing Au and Pd supported catalysts, while utilizing hydrogen peroxide 35% (H2O2) as the oxidant, H2O2 is very cheap, mild, and an environment friendly reagent, which produced water as the only by-product. Various proportions of Au-Pd catalysts on carbon and titanium oxide activated as supports were synthesized through the use of sol immobilization catalyst synthesis technique. Characterization of the synthesized catalysts was performed using X-Ray Diffraction (XRD), Brunauer-Emmett-Teller (BET), Field Emission Scanning Electron Microscopy (FESEM), and Transmission Electron Microscopy (TEM). It was found that the synthesized Au-Pd/ activated carbon catalyst was beneficial for the solvent free oxidation of benzyl alcohol after its containing high surface area measuring 871 m2g-1. Analysis of the TEM data and particle dimension revealed smaller and narrower particle size of 1 wt%. Thus, the distribution of Au-Pd/C was attained. Carbon-supported bimetallic catalysts presented a higher conversion compared to catalysts that are supported titanium oxide (TiO2) for for the oxidation reaction of benzyl alcohol. It was determined that this technique was a suitable process for catalyst synthesis with high selectivity, same distribution of the particle size and activations.
This study aimed at revealing the degree of availability of standards of word problems in mathematics books for the first three grades of the basic stage in Palestine. For this purpose, the researcher prepared an analysis tool and a list of criteria consisting of two areas: linguistic formulation and mathematical content. Every area had seven items. The results of the study showed that the third-grade mathematics book has the highest degree of availability of the standards with 85.75%, and then came the second-grade mathematics book with 83.12%. Finally, the first-grade mathematics book came with 80.13%. In the light of the previous results, the researcher recommended to develop the language of word problems, to take into account their i
... Show MoreIn the current study, new derivatives were synthesized by reaction of N-hydroxyphthalimide with chloro acetyl chloride in the presence of Et3N as a base to form 1,3-dioxoisoindolin-2-yl 2-chloroacetate (B1), which in turn enters several reactions with different amines where it interacts with primary amines to give 1,3-dioxoisoindolin-2-yl acetate derivatives (B2-B4) in basic medium, in the same way it interacts with these amines but with adding KNCS to form thiourea derivatives (B5-B7). It also reacts with diamines to give bis(azanediyl) derivatives (compounds B8-B10). The prepared derivatives were diagnosed using infrared FTIR and 1HNMR,13CNMR for some derivatives. Compounds B4, B5 and B9 were measured as corrosion inhibitors the inhibitio
... Show MoreIn this work, the extraction of glycyrrhizin from Licorice using bulk liquid membrane technique was developed and optimized. The effect of various parameters such as pH of stripping and donor solutions, temperature, stirring speed and kinetic parameters were investigated. Moreover, to study the impact of the polarity of membrane solvent, two types of extraction solvents were used as a membrane solvent: n-Hexane was used as a non-polar solvent and 1-Hexanol was as a polar solvent. The optimum extraction condition was found (95.53%) using 1-Hexanol, rotating speed was 400 rpm, and pH of the acceptor and donor solutions were 8 and 5.5, respectively. The reaction kinetics constants ( and ) for the transport of glycyrrhizin from the donor pha
... Show MoreBox-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been
... Show MoreIn this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the
... Show MoreAs regional development, as a matter of course, poses a number of systemic, scientific and political problems. While the issue of development is primarily at the national level to the limits of World War II in the industrialized world and to the 1960s borders in most Third World countries, the increasing awareness of regional disparities has led to the regional issue Were taken into consideration in the early 1960s and 1970s in most industrialized and developing countries alike. The local issue was only introduced in the early 1980s. The awareness of regional disparities and the fact that the regions do not have the same potential and that some regions have the resources to enable them to develop, grow and develop, unlike other r
... Show MoreA cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm
... Show MoreThe aim of research is to identify the effect of using Waks strategy upon acquiring the psychological concepts and mind habits for students in the college of education. An experimental design with a partial adjustment of two experimental and control groups as well as a posttest were employed. The researcher divided the study sample into two groups: group one consisted of (38) students to represent the experimental group that was taught according to the waks strategy, and group two consisted of (35) students to represent the control group that was taught according to the traditional method. The sample was chosen based on some variables namely (Intelligence, Prior knowledge). The researcher has designed the research tools as th
... Show MoreThis study aims to develop a thermosensitive mucoadhesive periodontal in situ gel of secnidazole for local release of drug for treatment of periodontitis, in order to increase the drug residence time and to increase patient compliance while lowering the side effects of the drug.
Cold method was used to prepare 30 formulas of secnidazole periodontal in situ gel, using different concentrations of thermosensitive polymers (poloxamer407 alone or in combination with poloxamer 188) and methyl cellulose (MC ) or hydroxypropyl methylcellulose (HPMC K4M )in different concentrations used as mucoadhesive polymer and the resultant formulations were subjected to several tests such as gelation temperature GT, appearance and pH value. The fo
... Show More