High smoke emissions, nitrogen oxide and particulate matter typically produced by diesel engines. Diminishing the exhausted emissions without doing any significant changes in their mechanical configuration is a challenging subject. Thus, adding hydrogen to the traditional fuel would be the best practical choice to ameliorate diesel engines performance and reduce emissions. The air hydrogen mixer is an essential part of converting the diesel engine to work under dual fuel mode (hydrogen-diesel) without any engine modification. In this study, the Air-hydrogen mixer is developed to get a homogenous mixture for hydrogen with air and a stoichiometric air-fuel ratio according to the speed of the engine. The mixer depends on the balance between the force exerted on the head surface of the valve and the opposite forces (the spring and friction forces) and its relation to decrease and increase the fuel inlet. Computational fluid dynamics (CFD) analysis software was utilised to study the hydrogen and airflow behaviour inside the mixer, established by 3.2 L engine. The Air-hydrogen mixer is examined with different speeds of engine1000, 2000, 3000 and 4000 RPM. Results showed air-hydrogen mixture was homogenous in the mixer. Furthermore, the stoichiometric air-fuel ratio was achieved according to the speed of the engine, the developed mixer of the AIR-Hydrogen mixing process provides high mixing homogeneity and engines with stoichiometric air-fuel ratios, which subsequently contributes to the high levels of efficiency in engine operation. In summary, the current study intends to reduce the emissions of gases and offer a wide range of new alternative fuels usage. While the performance of the diesel engine with the new air-hydrogen mixer needs to be tested practically.
Abstract:
The aim of this research is to highlight the importance of reducing the cost of a flight ticket by using information technology and the Internet, in the process of purchasing tickets for electronic flights, and to shift from the traditional method of purchasing and payment operations to the electronic method, to reduce the financial and non-financial risks associated with the traditional purchase process, as well as saving the cost Time, effort and money for the customer, and the researcher used the deductive approach in linking the variables (Internet of Things technology and reducing the costs of air tickets) wi
... Show MoreIn this work, an experimental study has been done to expect the heat characteristics and performance of the forced-convection from a heated horizontal rectangular fins array to air inside a rectangular cross-section duct. Three several configurations of rectangular fins array have been employed. One configuration without notches and perforations (solid) and two configurations with combination of rectangular-notches and circular-perforations for two various area removal percentages from fins namely 18% notches-9% perforations and 9% notches-18% perforations are utilized. The rectangular fins dimensions and fins number are kept constant. The fins array is heated electrically from the base
... Show MoreThe current study was conducted to demonstrate the effects of air pollution on different biochemical parameters inCitrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected tocollect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and closeto the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonalsamples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters totalchlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugarcontent, proline, electrical conductivity, cadmium and lead. The results of Citr
... Show MoreIn Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c
... Show MoreThis study aims to evaluate the influence of the air abrasion of dentin on the shear bond strength of lithium disilicate using three different types of luting cements. Sixty cylindrical specimens were milled from lithium disilicate CAD/CAM blocks (IPSe.max CAD). Sixty sound human maxillary premolar teeth were decoronated to the level of peripheral dentin, then randomly divided into three groups according to the type of luting cement used for the cementation of the lithium disilicate specimens (n = 20); Group A: Glass ionomer cement (Riva Self- Cure); Group B: Adhesive resin cement (Rely X Ultimate); Group C: Self-adhesive resin cement (Rely X U200). Each group was then further subdivided into two subgroups (n=10); Subgroups AI, BI, and CI,
... Show MoreIn this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel
... Show MoreThe effect of air injection device on the performance of airlift pump used for water pumping has been studied numerically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90 (for conventional) to 22.5 (for modified). Continuity and Navier-Stokes equations in turbulent regime with an appropriate two-phase flow model (VOF) and turbulent model ( ) in two dimensions axisymmetry flow were formulated and solved by using the known package FLUENT version (14.5). The numerical and experimental investiga
... Show MoreThis research include synthesized and characterization the compound [I] by reaction terephthaldehyde , mercaptoacetic acid and thiosemicarbazide with concentrated sulfuric acid then this compound reaction with ethyl chloroacetate and sodium acetate to product ester compound [II],the latter compound reaction with hydrazine hydrate to synthesized acid hydrazide [III] after that reaction with 4-alkoxy benzaldehyde[IV]n to synthesized Schiff bases compounds [V]n, the compound [VI] synthesized via reaction compound [I] with chloroacetic acid and sodium acetate then the compound[VI] reaction with 2-phenylenediamine in 4 N hydrochloric acid to product benzimidazole compound[VII]. The compounds characterized by melting points, FTIR and 1HNMR spectr
... Show MoreAn infant incubator in the neonatal intensive care unit (NICU) is a medical instrument of care that provides oxygen, warmth and moisture to a newborn baby. Due to environmental conditions affecting the infants foster babies may experience discomfort and pain at some point. Thus, this study aimed to assess ambient air quality in neonatal incubators to improve the environmental quality of neonatal intensive care units and safety. Air pollutants concentrations consisting of particulate matter (pm2.5, pm10), hydrocarbons (HOCH), volatile organic compounds (VOC), air quality index (AQI), humidity and temperature, were measured at four selected Baghdad hospitals (Al-Karkh and Rusafa) . The results showed that the increase in rela
... Show More
