Background: Sialosis described as a specific consequence of diabetes. In diabetic sialosis, the increased volume of the glands is due to the infiltration of adipose in the parenchyma. The B-scan ultrasonography is a generally accepted tool for determining parotid gland enlargement. Oral health is, to a greater extent, dependent on quality and quantity of saliva, both of which may be altered in diabetics. This study was established to detect the enlargement of parotid gland in diabetic patient and study the changes in physical properties of saliva and its relation with the salivary gland enlargement. Subjects, Materials and Methods: A cross-sectional study with highly specified criteria with ages ranged (20-65) years, male and female subject
... Show MoreCertain bacterial and viral infectious agents may play a role in the activation of inflammation in atherosclerosis lesions. Epidemiological studies indicate that infectious agents may predispose patients to atherosclerosis as Infections have been associated with an increased risk of this disease. Moreover, a positive antibody status has been detected against some infectious organisms associated with atherosclerotic rupture. Infectious agents found in human atheroma, which may directly cause or accelerate atherosclerosis , include many pathogens but the present study focused on Helicobacter pylori, hepatitis B virus surface antigen and C. In order to evaluate the possible association between H. pylori, HBV, and HCV infections and the risk of
... Show MoreBackground: The main purpose of this study is to find if there is any correlation between the level of C-reactive protein (CRP) in gingival crevicular fluid with its serum level in chronic periodontitis patients and to explore the differences between them according to the probing depth. Materials and methods: Forty seven male subjects enrolled in this study. Thirty males with chronic periodontitis considered as study group whom further subdivided according to probing depth into subgroup 1 with pocket depth ≤6mm, subgroup 2 with pocket depth >6mm. The other 17 subjects considered as controls. For all subjects, clinical examination where done for periodontal parameters plaque index (PLI), gingival index (GI), bleeding on probing (BOP),
... Show MoreThe fluorescence emission of Rhodamine 6G (R6G) and Acriflavine dyes in PMMA polymer have been studied by changing the irradiation and exposure time of laser light to know the effect of this parameter. It was found that the fluorescence intensity decreases in the polymer samples doped dyes as the exposure time increases and then reaches stabilization at long times, this behavior called photobleaching, which have been shown in liquid phase less than solid phase. Using 2nd harmonic with wavelength 530 nm laser, the photobleaching effect in the two dye-doped polymers different solvent but same was studied. It was observed that photobleaching of by different solution and by using dip spin coating the photobleaching seem in liquid phase
... Show MoreWe have investigated twenty five patients with type-2 diabetes mellitus aged (35-60) years and fifteen healthy persons as control group to detect Anti-Helicobacter pylori IgG antibody. All studied groups were carried out to measure fasting blood sugar, anti- Glutamic acid decarboxylase (GAD), anti-? islets cells antibody by IFAT, Anti-H. pylori IgG antibody by ELISA technique. There was significant elevation in the concentration of fasting blood sugar than in control group (P < 0.05), the patients had negative results for anti-GAD antibody and anti- ? islets cells antibody, there were significant differences (P < 0.05) of anti-H. pylori IgG antibody in 28 % of patients had type-2 diabetes than control group. This lead to suggestion that typ
... Show MoreThe new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and dis
... Show MoreObjectives: To determine the effectiveness of the instructional program on patients’ knowledge about home safety while receiving anti-cancer treatment at Al- Karama Teaching Hospital in Al-Kut City.
Methodology: A quasi-experimental design is conducted through the application of a pre-test and post-test approach for the study and control groups from February 5th, 2020 to April 25th, 2020. A non–probability (purposive) sample of (50) patients treated at the Blood Disease and Oncology Center is selected and divided into two groups. Each group contains (25) patients as control and study groups. An instrument is constructed that is comprised of two parts; t
... Show MoreObjective: The aims of present study to detect the effectiveness of instruction program of non-pharmacological guideline on blood pressure and laboratory test.
Methodology: A pre-experimental study was conducted in Al-Sader Teaching Hospital from 8th of September 2019 to 25th of May 2020, in order to find out the effectiveness of instruction program concerning non-pharmacological guideline on controlling essential hypertension among patients. A non- probability (purposive sample) of 50 patients with essential hypertension is selected. Those patients are already diagnosed with Essential Hypertension
... Show MoreA simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi
... Show More