Summary Kidney transplantation is widely performed nowadays as an optimal treatment of end stage kidney diseases. Complications such as stenosis in graft renal arteries anastomosis may occur. Different suturing techniques are available for renal artery anastomosis. We aimed to compare the incidence of renal artery stenosis of the transplanted kidney when two suture techniques (continuous or interrupted) used for renal artery anastomosis. Therefore, a retrospectively comparative study was conducted on 44 patients managed with kidney transplantation during the years 2009-2011. Patients assigned into two groups; first group included 20 patients namely, continuous suture group, and the second group included 24 patients in whom the allograft arteries were anastomosed with an interrupted suture technique. Post transplantation, the velocity of blood flow in the renal and iliac arteries at the site of anastomosis was assessed using color duplex ultrasonography for the presence of graft renal artery stenosis. In each group only one case developed We graft renal artery stenosis with no statistically significant difference in the incidence rate. In conclusion, No difference in the incidence of graft renal artery stenosis in different anastomosis techniques. Other factors such as gentle handling of tissue, enough spatulation, margin eversion, and comparable diameter of the anastomosed vessels may be more important in the prevention of renal allograft stenosis than the type of suture technique used.
Back ground: This in vitro study was carried out to investigate the effect of post space regions (coronal, middle and apical), Time and the mode of polymerization (dual, self-cured) of the cements used on the bond strength between translucent fiber post and root dentin by using push-out test. Materials and Methods: Forty eight extracted mandibular first premolars (single root) were instrumented with ProTaper Universal system files (for hand use) and obturated with gutta percha for ProTaper and AH26® root canal sealer following the manufacturer instructions, after 24 hours post space was prepared using FRC postec® plus drills no.3 creating 8 mm depth post space. The prepared samples were randomly divided into two main groups (24 samples ea
... Show MoreThe goal of this paper is to show the kinematic characteristics of gaseous stellar dynamics using scaling coefficient relationships (such as Tully-Fisher) in different spiral galaxies. We selected a sample of types of spiral morphology (116 early, 150 intermediate, and 146 late) from previous literature work, and used statistical software (statistic-win-program) to find out the associations of multiple factors under investigation, such as the main kinematic properties of the gaseous-stellar (mass, luminosity, rotational speed, and baryons) in different types of spiral galaxies. We concluded that there is a robust positive connection between Log Vrot.max.) and Log Mstar(B-V), as well as between Log Vrot.max. and Log Mbar (
... Show MoreAbstract Kidney stones are one of the most common and most painful medical problems known (1). Nurses assess and monitor patients through diagnosis and treatment and teach patients how to avoid recurrence of stones (2). A descriptive study was conducted on 150 patients diagnosed with recurrent kidney stones, who were attending the out patients consultation urology disease clinics at surgical specialties, Al-Kadhimia, Al-Yarmook, and Al-Karama Teaching Hospital and Extracorporeal shock wave lithotripsy (ESWL) departments for the period from the 1st of Feb. 2002 through to the end of May 2004. The aim of
This paper deals with a method called Statistical Energy Analysis that can be applied to the mechanical and acoustical systems like buildings, bridges and aircrafts …etc. S.E.A as a tool can be applied to the resonant systems in the circumstances of high frequency or/and complex structure». The parameters of S.E.A such as coupling loss factor, internal loss factor, modal density and input power are clarified in this work ; coupled plate sub-systems and explanations are presented for these parameters. The developed system is assumed to be resonant, conservative, linear and there is an equipartition of energy between all the resonant modes within a given frequency band in a given sub-system. The aim of th
... Show MoreBN Rashid…, Special Education, 2022
This paper aims to evaluate large-scale water treatment plants’ performance and demonstrate that it can produce high-level effluent water. Raw water and treated water parameters of a large monitoring databank from 2016 to 2019, from eight water treatment plants located at different parts in Baghdad city, were analyzed using nonparametric and multivariate statistical tools such as principal component analysis (PCA) and hierarchical cluster analysis (HCA). The plants are Al-Karkh, Sharq-Dijlah, Al-Wathba, Al-Qadisiya Al-Karama, Al-Dora, Al-Rasheed, Al-Wehda. PCA extracted six factors as the most significant water quality parameters that can be used to evaluate the variation in drinkin
Background: Prosthodontic services have changed markedly due to an introduction of new materials, techniques and treatment options. The aim of this study were to identify the type of materials and the methods used by dental practitioners in their clinics to construct conventional complete dentures and to specify the type and design for removable partial dentures (RPDs); and to then compare them with those taught in dental schools. Materials and methods: A total of 153 dental practitioners in Sulaimani city completed a written questionnaire. The questionnaire included 19 questions regarding complete and RPDs fabrication. Results: Most of the practitioners provide complete dentures (81.6%) and RPDs (95.3%) in their clinics. Polyvinyl silox
... Show More
