Objective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time exposure, and radiologic reduction of the fracture using Chang criteria. Results: The setup, fluoroscopic exposure, and surgical times were shorter in the lateral decubitus group with statistical significance. The collodiaphyseal angles, the tip-to-apex distance, and the radiological fracture reduction were not significantly different between two groups. Conclusions: The lateral decubitus positioning is superior to the supine position in setup, fluoroscopic exposure, and surgical times
Background: Determination of sex and estimation of stature from the skeleton is vital to medicolegal investigations. Skull is composed of hard tissue and is the best preserved part of skeleton after death, hence, in many cases it is the only available part for forensic examination. Lateral cephalogram is ideal for the skull examination as it gives details of various anatomical points in a single radiograph. This study was undertaken to evaluate the accuracy of digital cephalometric system as quick, easy and reproducible supplement tool in sex determination in Iraqi samples in different age range using certain linear and angular craniofacial measurements in predicting sex. Materials and Method The sample consisted of 113of true lateral cepha
... Show MoreThe skirt foundation is one of the powerful types of foundations to resist the lateral loads produced from natural forces, such as earthquakes and wind action, or from the type of structures, such as oil platforms and offshore wind turbines.
This research experimentally investigated the response of skirted footing resting on sandy soil of different states to lateral applications of loads on a small-scale physical model manufactured for this purpose. The parameters studied are the dista
Background: A worldwide health epidemic, type 2 diabetes mellitus was significantly influenced by chronic inflammation, which led to increased insulin resistance (IR). The most widely practiced form of therapy used to control musculoskeletal pain in people with diabetes is non-steroidal anti-inflammatory drugs (NSAIDs), which provide their action by inhibiting cyclooxygenase enzyme (COX). COX1, COX2, and COX3 are distinct isoforms of the cyclooxygenase enzyme. The potential anti-inflammatory benefits of cyclooxygenase-2 (COX-2) inhibitors, both selective and non-selective, have been investigated concerning the management of type 2 diabetes patients. Objective: the purpose of this research is to explore the impact of highly selective
... Show MoreRetreatment Efficacy of Continuous Rotation Versus Reciprocation Kinematic Movements in Removing Gutta-Percha with Calcium Silicate-Based Sealer: SEM Study, Raghad Noori Nawaf*, Ra
ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear imp
... Show MoreL1 adaptive controller has proven to provide fast adaptation with guaranteed transients in a large variety of systems. It is commonly used for controlling systems with uncertain time-varying unknown parameters. The effectiveness of L1 adaptive controller for position control of single axis has been examined and compared with Model Reference Adaptive Controller (MRAC). The Linear servo motor is one of the main constituting elements of the x-y table which is mostly used in automation application. It is characterized by time-varying friction and disturbance.
The tracking and steady state performances of both controllers have been assessed fo
... Show MoreAbstract
The research addresses the specification table and the extent of its use in developing achievement tests, as well as detects the obstacles to its use through a sample of (120) respondents from the faculty members in some Baghdad schools and colleges. After unpacking and processing the data statistically, the research reached several results: the study sample do not use the test map in the development of their tests, as their percentage reached (82%) and there are no statistically significant differences in the use of the specification table by the sample members according to their place of work or the number of years of experience. The results also revealed the most important reasons that prevent the use
... Show More