Preferred Language
Articles
/
BBij7pYBVTCNdQwCTJQT
Expired azithromycin and cephalexin as corrosion inhibitors for aluminum in saline-acidic solution
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Studying of the optical properties of poly (vinyl alcohol) films using Aluminum sulphate as additive by measuring allowed direct transition energy gap
...Show More Authors

The change in the optical band gap and optical activation energy have been investigated for pure Poly (vinyl alcohol)and Poly (vinyl alcohol) doped with Aluminum sulphate to proper films from their optical absorption spectra. The absorption spectra were measured in the wave range from (200-700) nm at temperature range (25-140) 0C. The optical band gap (Eg) for allowed direct transition decrease with increase the concentration of Aluminum sulphate. The optical activation energy for allowed direct transition band gap was evaluated using Urbach- edges method. It was found that ?E increases with increasing the concentration of Al2 (SO4)3 and decreases when temperature increases.

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Neuroquantology
HOMO-LUMO Energies and Geometrical Structures Effecton Corrosion Inhibition for Organic Compounds Predict by DFT and PM3 Methods
...Show More Authors

A theoretical study on corrosion inhibitors was done by quantum calculations includes semi-empirical PM3 and Density Functional Theory (DFT) methods based on B3LYP/6311++G (2d,2P). Benzimidazole derivative (oxo(4- ((phenylcarbamothioyl) carbamoyl)phenyl) ammonio) oxonium (4NBP) and thiourea derivative 2-((4- bromobenzyl)thio) -1H-benzo[d] imidazole (2SB) were used as corrosion inhibitors and an essential quantum chemical parameters correlated with inhibition efficiency, EHOMO (highest occupied molecular orbital energy) and ELUMO (lowest molecular orbital energy). Other parameters are also studied like energy gap [ΔE (HOMO-LUMO)], electron affinity (EA), hardness (Δ), dipole moment (μ), softness (S), ionization potential (IE), absolut

... Show More
View Publication Preview PDF
Scopus (80)
Crossref (72)
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Color stability of nano resin-modified glass Ionomer restorative cement after acidic and basic medications challenge
...Show More Authors

Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Color stability of nano resin-modified glass Ionomer restorative cement after acidic and basic medications challenge
...Show More Authors

Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over a thr

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Sat May 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An Assessment of Oral Health in Hypertensive Patients Treated with HMG-CoA Reductase Inhibitors (Statins)
...Show More Authors

Background: Hypertension is a chronic medical condition in which the blood pressure in the arteries is elevated, it's classified as either primary (essential) hypertension or secondary hypertension, and it increases the risk of ischemic heart disease, peripheral vascular disease and other cardiovascular diseases. Several classes of medications collectively referred to as antihypertensive drugs like beta blockers, calcium channel blockers, angiotensin converting enzyme (ACE) inhibitors, angiotensin receptor blockers, renin inhibitors and statins (HMG-CoA) reductase inhibitor. Statin medication may have some beneficial effects when subjects have dental plaque or signs of periodontitis as gingival bleeding. The purpose of this study were to as

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 23 2025
Journal Name
Baghdad Science Journal
Preparation, Characterization, and Studying the Biological Activity of Schiff Base Metal Complexes Derived From Cephalexin With 3-Methoxy-4-Hydroxy Benzaldehyde
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Effect of irrigation by saline magnetized water on seed germination and seedling growth of wheat Triticum aestivum
...Show More Authors

The effect of saline magnetized water irrigation on seed germination and seedling growth of wheat cultivar Iraq were studied. Irrigation water was supplemented with different levels of Sodium chloride 6, 12 or 18 mmhos/ cm in addition control treatment, and passed through a proper magnetic felid with 1000, 1250, 1500 or 2000 gaus in addition control treatment. The results showed significantly stimulated shoot development and led to the increase of germination, seedling emergence, area leaf, length of shoot and root and fresh and dry weight compared to the controls. Results also showed significant interaction between saline water and magnetized water. So, using magnetic treatment of saline water could be a promising technique

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jan 02 2017
Journal Name
Al-nahrain Journal For Engineering Sciences (njes)
Experimental Investigation of Forced Convection Heat Transfer and Pressure Drop in Open Cell Aluminum Fins
...Show More Authors

Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical Behavior of Chemical Conversion Coated Aluminum ASA6061 in Chromic Acid
...Show More Authors

The corrosion behavior of bare and chemical conversion coated (through anodizing) aluminum ASA 606 I in stagnant chromic acid solutions . Solutions of 2, 6 & J O wt. % Cr03 at 45°C, have been investigated using polarization technique. The anodizing experiments were conducted under fixed conditions of 35 minute exposure time and 30 volt supplied voltage. The most important feature achieved was the great difference in behavior between the anodic polarization curves for bare and anodized aluminum in different concentrations of chromic acid solutions.

View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Monitoring of Defects Concentration in Deformed Aluminum Using Doppler Broadening Technique
...Show More Authors

Doppler broadening of the 511 keV positron annihilation ??? ? was used to estimate the concentration of defects ?? different deformation levels of pure alnminum samples. These samples were compressed at room temperature to 15, 22, 28, 38,40, and 75 % thickness reduction. The two-state ^sitron-trapping model has been employed. 'I he s and w lineshape parameters were measured using high-resolution gamma spectrometer with high pure germanium detector of 2.1 keV resolution at 1.33 MeV of 60Co. The change of defects concentration (Co) with the deformation level (e) is found to obey an empirical formula of the form Cd - A £ B where A and ? are positive constants that depend mainly on the deformation procedure and the temperature at which the def

... Show More
View Publication Preview PDF