The objectives of the study were to identify the incidence rate and characteristics of adverse drug events (ADEs) in nursing homes (NHs) using the ADE trigger tool and to evaluate the relationships between resident and facility work system factors and incidence of ADEs using the System Engineering Initiative for Patient Safety (SEIPS) model. The study used 2 observational quantitative methods, retrospective resident chart extraction, and surveys. The participating staff included Directors of nursing, registered nurses, certified nurse assistants (CNAs). Data were collected from fall 2016 to spring 2017 from 11 NHs in 9 cities in Iowa. Binary logistic regression with generalized estimated equations was used to measure the association between ADE incidence and resident and facility characteristics. We extracted data from 755 medical charts and conducted 33 staff surveys. There were 6.13 ADEs per 100 residents per month. More than half were fall‐related (51.1%), and half of those were due to hypotension. Regression analysis revealed significant associations between ADEs and opioid analgesics, psychotropic medications, warfarin, skilled care, consultant pharmacist accessibility, nurse‐physician collaboration, CNA vital sign assessment skills, number of physician visits, nurse workload, and use of electronic health records. Five resident characteristics (skilled care, dementia, use of opioids, warfarin, psychotropics) and variables from 5 domains of the facility work system (organization, task, environment, person, technology) had significant associations with ADE incidence. The SEIPS model successfully identified work system factors influencing ADEs in NHs.
In this research work, a simulator with time-domain visualizers and configurable parameters using a continuous time simulation approach with Matlab R2019a is presented for modeling and investigating the performance of optical fiber and free-space quantum channels as a part of a generic quantum key distribution system simulator. The modeled optical fiber quantum channel is characterized with a maximum allowable distance of 150 km with 0.2 dB/km at =1550nm. While, at =900nm and =830nm the attenuation values are 2 dB/km and 3 dB/km respectively. The modeled free space quantum channel is characterized at 0.1 dB/km at =860 nm with maximum allowable distance of 150 km also. The simulator was investigated in terms of the execution of the BB84 prot
... Show MoreThis paper studies the combination fluid viscous dampers in the outrigger system to add supplementary damping into the structure, which purpose to remove the dependability of the structure to lower variable intrinsic damping. It works by connecting the central core, comprising either shear walls or braced frames, to the outer perimeter columns.
The modal considered is a 36 storey square high rise reinforced concrete building. By constructing a discrete lumped mass model, and using frequency-based response function, two systems of dampers, parallel and series systems are studied. The maximum lateral load at the top of the building is calculated, and this load w
... Show MoreThis paper presents a method to organize memory chips when they are used to build memory systems that have word size wider than 8-bit. Most memory chips have 8-bit word size. When the memory system has to be built from several memory chips of various sizes, this method gives all possible organizations of these chips in the memory system. This paper also suggests a precise definition of the term “memory bank” that is usually used in memory systems. Finally, an illustrative design problem was taken to illustrate the presented method practically.
This paper presents a method to organize memory chips when they are used to build memory systems that have word size wider than 8-bit. Most memory chips have 8-bit word size. When the memory system has to be built from several memory chips of various sizes, this method gives all possible organizations of these chips in the memory system. This paper also suggests a precise definition of the term “memory bank” that is usually used in memory systems. Finally, an illustrative design problem was taken to illustrate the presented method practically
Theoretical and experimental investigations of the transient heat transfer parameters of constant heat flux source subjected to water flowing in the downward direction in closed channel are conducted. The power increase transient is ensured by step change increase in the heat source power. The theoretical investigation involved a mathematical modeling for axially symmetric, simultaneously developing laminar water flow in a vertical annulus. The mathematical model is based on one dimensional downward flow. The boundary conditions of the studied case are based on adiabatic outer wall, while the inner wall is subjected to a constant heat flux. The heat & mass balance equation derived for specified element of bulk water within the annulu
... Show MoreIn this paper, a random transistor-transistor logic signal generator and a synchronization circuit are designed and implemented in lab-scale measurement device independent–quantum key distribution systems. The random operation of the weak coherent sources and the system’s synchronization signals were tested by a time to digital convertor.