The objectives of the study were to identify the incidence rate and characteristics of adverse drug events (ADEs) in nursing homes (NHs) using the ADE trigger tool and to evaluate the relationships between resident and facility work system factors and incidence of ADEs using the System Engineering Initiative for Patient Safety (SEIPS) model. The study used 2 observational quantitative methods, retrospective resident chart extraction, and surveys. The participating staff included Directors of nursing, registered nurses, certified nurse assistants (CNAs). Data were collected from fall 2016 to spring 2017 from 11 NHs in 9 cities in Iowa. Binary logistic regression with generalized estimated equations was used to measure the association between ADE incidence and resident and facility characteristics. We extracted data from 755 medical charts and conducted 33 staff surveys. There were 6.13 ADEs per 100 residents per month. More than half were fall‐related (51.1%), and half of those were due to hypotension. Regression analysis revealed significant associations between ADEs and opioid analgesics, psychotropic medications, warfarin, skilled care, consultant pharmacist accessibility, nurse‐physician collaboration, CNA vital sign assessment skills, number of physician visits, nurse workload, and use of electronic health records. Five resident characteristics (skilled care, dementia, use of opioids, warfarin, psychotropics) and variables from 5 domains of the facility work system (organization, task, environment, person, technology) had significant associations with ADE incidence. The SEIPS model successfully identified work system factors influencing ADEs in NHs.
Objective (s): To determine factors associated with the pregnancy complications (Maternal age, education,
obstetrical history, gravidity, birth space interval, and smoking).
Methodology: A cross-sectional study conducted at Al- washash & Bab-almoadham primary health care
centers. The sample was (non probability convenient sample) which included (550) pregnant women. The
study started from 1st April 2014 to 1
st of April 2015. The data was collected by direct interview using
special questionnaire to obtain socio-demographic information.
Results: the result shows that mean age of the subjects was 26.5± 4.39 years, 57.8% were housewives, the
sample included 103 premature uterine contractions, 98 pregnancy induce
Buildings begin to deteriorate gradually over time due to several factors, including environmental influences, improper use of the building, and neglected repairs for damages during the building's life span. Effective maintenance practices can minimize operational costs, extend the life of building systems and components, improve energy efficiency, and maintain property value. This paper aims to review articles related to building maintenance to identify factors affecting maintenance practices. After conducting the review, the result was that there were 33 factors affecting building maintenance categorized into six groups: management-related factors, manpower-related factors, technical-related factors, financial-
... Show MoreTwo simple, rapid, and useful spectrophotometric methods were suggest or the determination of sulphadimidine sodium (SDMS) with and without using cloud point extraction technique in pure form and pharmaceutical preparation. The first method was based on diazotization of the Sulphdimidine Sodium drug by sodium nitrite at 5 ºC, followed by coupling with α –Naphthol in basic medium to form an orange colored product . The product was stabilized and its absorption was measured at 473 nm. Beer’s law was obeyed in the concentration range of (1-12) μg∙ml-1. Sandell’s sensitivity was 0.03012 μg∙cm-1, the detection limit was 0.0277 μg∙ml-1, and the limit of Quantitation was 0.03605μg
... Show MoreThe purpose of this study to synthesize and characterize silver nanoparticles using phenolic compounds obtained from Camellia sinensis, to test the antibacterial properties of biosynthesized nanoparticles on the formation of biofilms in multidrug-resistant Pseudomonas aeruginosa. Ten isolates of P. aeruginosa were obtained from the Genetic Engineering and Biotechnology Institute laboratories of the University of Baghdad. By using the VITEK-2 system and culturing the isolates on cetrimide agar, the diagnosis was confirmed. Camellia sinensis silver nanoparticles (CAgNPs) were created using an extract of the plant's aqueous and methanolic leaves. Based on the results of the nanoparticle synthesis, spherical nanoparticles that may be single or
... Show MoreThe present study was conducted to determine histopathological changes caused by chronic effect of Nitrofurantoin(NFT) in The albino mice Testes. The Study included 40 mice were divided on the five groups: the first group taken distilled water and become control group . the remaining group which are exposure with NFT drug in concentration (100-150-200-250) mg / kg, respectively, Doses were given orally for a period (month and two months). The results of histopathological changes included occurrence of congestion in the blood vessel and degeneration of spermatogonia and aggregation of spermatids in the lumen of semineferous tubules and inhibition of spermatogensis process and decrease of sperm inside the lumen
... Show MoreThis paper is concerned with introducing and studying the first new approximation operators using mixed degree system and second new approximation operators using mixed degree system which are the core concept in this paper. In addition, the approximations of graphs using the operators first lower and first upper are accurate then the approximations obtained by using the operators second lower and second upper sincefirst accuracy less then second accuracy. For this reason, we study in detail the properties of second lower and second upper in this paper. Furthermore, we summarize the results for the properties of approximation operators second lower and second upper when the graph G is arbitrary, serial 1, serial 2, reflexive, symmetric, tra
... Show MoreGlobally, Sustainability is very quickly becoming a fundamental requirement of the construction industry as it delivers its projects; whether buildings or infrastructures. Throughout more than two decades, many modeling schemes, evaluation tools, and rating systems have been introduced en route to realizing sustainable construction. Many of these, however, lack consensus on evaluation criteria, a robust scientific model that captures the logic behind their sustainability performance evaluation, and therefore experience discrepancies between rated results and actual performance. Moreover, very few of the evaluation tools available satisfactorily address infrastructure projects. The res