Background: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15 for each stage) and 18 healthy subjects as controls were included. The levels of all salivary biomarkers and clinical parameters were significantly higher in periodontitis subjects than in the controls. The ROC curve showed that MMP-8, MMP-9, TIMP-1, MMP-8/TIMP-1, and MMP-9/TIMP-1 had statistically significant diagnostic accuracy, with areas under the curve (AUCs) of 0.892, 0.844, 0.920, 0.986, and 1.000, respectively, when distinguishing periodontitis from the controls. Similarly, these biomarkers showed significant diagnostic accuracy in the differentiation of S1 periodontitis from the controls (AUC range from 0.902 to 1.000). Conclusions: This study suggested that salivary biomarkers exhibited high diagnostic accuracy in distinguishing periodontal health from periodontitis in general as well as S1 periodontitis. Furthermore, TIMP-1 could differentiate S1 from S3.
Background: Chronic periodontitis (CP) is greatly prevalent condition of inflammatory behavior. Salivary biomarker total antioxidants capacity (T-AOC) status, may be related to both periodontal condition and oral hygiene. Aims of the study: To assess the level of salivary T-AOC of patients with chronic periodontitis in comparison to healthy control and to correlate between the level of this marker with the clinical periodontal parameters (plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD), and clinical attachment level (CAL)). Materials and Methods: Ninety subjects of males and females with an age ranged between (35-55) years were participated in this study. Participants were divided into two grou
... Show MoreBackground: Saliva is a specific bio-fluid with important biomarkers. Analyzing any alternation in these markers could give valuable information, in relation to oral health status parameters. The aim of this study was to investigate the level of α -amylase in unstimulated whole saliva of healthy, primary school children in relation to some oral health parameters. Materials and Methods: A questionnaires consisted of demography and medical histories of participants were filled by children families. Saliva samples were collected for 5- minutes between 9:00 -11:00 AM from 114 healthy students aged 6-13 years, divided into four age groups. Flow- rate, Plaque and Gingival Index were assessed and dentition status was investigated by DMFT/dmft
... Show MoreAfter baking the flour, azodicarbonamide, an approved food additive, can be converted into carcinogenic semicarbazide hydrochloride (SEM) and biurea in flour products. Thus, determine SEM in commercial bread products is become mandatory and need to be performed. Therefore, two accurate, precision, simple and economics colorimetric methods have been developed for the visual detection and quantitative determination of SEM in commercial flour products. The 1st method is based on the formation of a blue-coloured product with λmax at 690 nm as a result of a reaction between the SEM and potassium ferrocyanide in an acidic medium (pH 6.0). In the 2nd method, a brownish-green colored product is formed due to the reaction between the SEM and phosph
... Show MoreA method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav
... Show MoreThe research includes the preparation of a new Schiff base(4-methyl-2-((2-phenyl hydrazineylidene)methyl)naphthalen-1-ol), which was subsequently, used to prepare a series of complexes using chlorides of Mn2+, Co2+, Cu2+, Cr3+, and Fe3+ ions. The synthesized compounds were characterized using various techniques such as elemental microanalysis (C.H.N), chloride content determination using Mohr’s method, FT-IR spectroscopy, UV-Visible, mass spectra, conductivity, DSC (Differential Scanning Calorimetry), and thermogravimetric analysis. Overall, the decay of the ligand and its metal complexes was recorded to determine their thermal stability and weight-loss profiles. The results indicated that ligand acts as a bidentate doner, coordinating wi
... Show MoreA sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and
... Show MoreThe purpose of this paper is to identifying the values of some physical and Bio- Kinematic variables during the performance of the jump spike serve skill, and identifying the effect of the proposed training program using intermittent training to develop some physical and Bio- Kinematic variables and accuracy of the jump spike serve skill among the research sample. The experimental method was used and the research was conducted on a deliberately chosen sample of the players of the Army Club, who were primarily advanced in volleyball, and the number of the sample was (10) players. The conclusions were reached that the proposed training program using intermittent training has a positive effect on some of the physical and Bio- Kinematic variabl
... Show MoreBackground: Vitamin D improves innate immunity by enhancing the expression of antimicrobial peptides. The antimicrobial action of cathelicidin is widespread and effective against cariogenic bacteria. This research aimed to investigate the effect of vitamin D deficiency on the level of salivary cathelicidin concerning dental caries experience.
Subjects and Methods: A case-control study was carried out, and the sample was composed of 80 females; the study group involved 40 females with a serum vitamin D concentration of less than 10 ng/ml. In addition to the control group involving 40 females wh
... Show MoreThis systematic review aimed to analyse available evidence to answer two focused questions about the efficacy of erythritol powder air‐polishing (EPAP) (i) as an adjunctive during active periodontal therapy (APT) and (ii) as an alternative to hand/ultrasonic instrumentation during supportive periodontal therapy (SPT). Additionally, microbiological outcomes and patient's comfort/perceptions were assessed as secondary outcomes.
PubMed, Cochrane and Medline were searched for relevant articles published before February 2021 following PRISMA guidelines. The search was conducted by three indep