Preferred Language
Articles
/
AxYRuYcBVTCNdQwCEV8k
The substitutions of Strontium by yttrium and their effects on Bi<sub>2</sub>Sr<sub>2</sub>-<sub>x</sub>Y<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10</sub>+<sub>δ</sub> superconducting compound
...Show More Authors
Abstract<p>Superconducting compound Bi<sub>2</sub>Sr2-<sub>x</sub>Y<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> were Synthesized by method of solid state reaction, at 1033 K for 160 hours temperature of the sintering at normal atmospheric pressure where substitutions Yttrium oxide with Strontium. When Y2O3 concentration (0.0, 0.1, 0.2, 0.3, 0.4 and 0.5). All specimens of Bi<sub>2</sub>Sr<sub>2</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> superconducting compounds were examined. The resistivity of electrical was checked by the four point probe technique, It was found that the optimum and maximum transition temperature T<sub>c</sub> = 125°K. The crystal structure studied by using XRD analysis and it was showed that the all specimens have tetragonal structures. Bi-2223phase increase by increasing Y<sub>2</sub>O<sub>3</sub> concentration up x=0.4, The increasing addition Yttrium oxide concentration produce increasing in high-phase (Bi-2223) and c lattice parameter.</p>
Scopus Crossref
View Publication
Publication Date
Thu Oct 23 2025
Journal Name
Baghdad Science Journal
Continuous Flow Injection-Turbidimetric Analysis for Determination of Cobalt (II) Ion in Alloys Using a Microcell with Irradiation Sources at 0–180° Using a Single Solar Cell as a Detector
...Show More Authors

A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Dec 23 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Shear bond strength of stainless steel brackets bonded to porcelain surface treated with 1.23% acidulated phosphate fluoride gel compared to hydro fluoric acid with silane coupling agent (In vitro comparative study)
...Show More Authors

Background: With the increasing demands for adult orthodontics, a growing need arises to bond attachments to porcelain surfaces. Optimal adhesion to porcelain surface should allow orthodontic treatment without bond failure but not jeopardize porcelain integrity after debonding.The present study was carried out to compare the shear bond strength of metal bracket bonded to porcelain surface prepared by two mechanical treatments and by using different etching systems (Hydrofluoric acid 9% and acidulated phosphate fluoride 1.23%). Materials and Methods: The samples were comprised of 60 models (28mm *15mm*28mm) of metal fused to porcelain (feldspathic porcelain). They were divided as the following: group I (control): the porcelain surface left u

... Show More
View Publication Preview PDF