The levels of circulating angiogenic and anti-angiogenic factors, namely vascular endothelial growth factor–A (VEGF-A) and soluble vascular endothelial growth factor receptor-1 (sVEGFR-1), have been linked to the development of renal dysfunction due to the proliferation of microvasculature within the kidneys of type 2 diabetic (T2DM) patients. The study aims to scrutinize serum levels of VEGF and sVEGFR-1 in a sample of Iraqi diabetic nephropathy patients to support their reliability as markers for the prediction of nephropathy in type 2 diabetes mellitus patients as well as to assess the ACE inhibitor’s effect on the levels of these two markers. Method: The ninety participants of this case-control study were split into three groups: thirty-five patients with T2DM and an equal number of patients with DN and the third group involve twenty apparently healthy individuals as the control group. The two diabetic groups have been further divided into four groups according to the ACE inhibitors use. Laboratory measurements involve the glycemic indices, renal function test with serum VEGF-A and sVEGFR-1. Results: the median serum levels of VEGF-A show valuable discrepancies between the three groups (p-value<0.05) but for sVEGFR-1 it doesn’t show a notable difference between the DM and the DN groups only(p-value> 0.05).
Hartree-Fock (HF) method relies in the calculations of nonlinear optical properties (NLO) for benzoic acid molecule. Also, another theoretical study is conducted by using the TD-DFT Density Functional Theory through B3LYP/High Base Set 6-311++G (2d,2p) on Gaussian program09. Moreover, an experimental study has been done to obtain the electrons spectrum for benzoic acid with and without ethanol. While the experimental study is done by using UV/VIS. spectrophotometer. Energy gap values of electronic transition between HOMO and LUMO is obtained from theoretical and experimental results. Consequently, the theoretical result for determining the energy gap calculated from EHOMO-LUMO wasvery close to the results of UV / VIS. spectrum. A theoretica
... Show MoreThroughout this paper, three concepts are introduced namely stable semisimple modules, stable t-semisimple modules and strongly stable t-semisimple. Many features co-related with these concepts are presented. Also many connections between these concepts are given. Moreover several relationships between these classes of modules and other co-related classes and other related concepts are introduced.
The primary objective of this research be to develop a novel thought of fibrewise micro—topological spaces over B. We present the notions from fibrewise micro closed, fibrewise micro open, fibrewise locally micro sliceable, and fibrewise locally micro-section able micro topological spaces over B. Moreover, we define these concepts and back them up with proof and some micro topological characteristics connected to these ideas, including studies and fibrewise locally micro sliceable and fibrewise locally micro-section able micro topological spaces, making it ideal for applications where high-performance processing is needed. This paper will explore the features and benefits of fibrewise locally micro-sliceable and fibrewise locally
... Show MoreKE Sharquie, AA Noaimi, MS Abass, American Journal of Dermatology and Venereology, 2019 - Cited by 4
has experienced a step-change since the inception of ambient mass spectrometry removed the requirement for samples to be investigated under vacuum conditions. Approaches based on surface– plasma interactions are especially promising, including PADI. Whilst the mechanisms involved in generating PADI spectra still need to be unravelled, PADI shows significant promise to become a valuable and versatile tool in the instrumental arsenal available to the surface analyst
The significance of the research lies in the fact that electronic technologies represent an important step in evaluating legal situations, and the research problem centered on the lack of attention to visual requirements and the absence of a clear image of legal situations that may be difficult for the referee to apply correctly in addition to the lack of focus on visual requirements and the unclear depiction of some legal cases which make it difficult for the referee to interpret them correctly This is because the referee's main tool is visual perception, which interprets live situations such as violations, fouls, and other cases that arise during a game Moreover, there are numerous responses and challenges in evaluating legal situ
... Show MorePhotovoltaic devices (PVs) were fabricated by spray-coating an ink of copper indium diselenide CuInSeR 2 R(CIS) nanocrystals as the light-absorbing layer. Without high-temperature post-deposition annealing, PVs were made on glass substrates with power conversion efficiencies of up to 1.5% and 0.9%, for Au and Mo coated respectively, under AM 1.5 illumination. UV–Vis spectrophotometer in the wavelength range 350–1500 nm. X-ray diffraction (XRD) and energy dispersive spectroscopy (EDS) analysis it is evident that CuInSeR 2 R have the chalcopyrite structure as the major phase and no secondary phase with a preferred orientation along (112) direction and The atomic ratio of Cu : In : Se in the nanocrystals is nearly 1 : 1 : 2.