Radio observations from astronomical sources like supernovae became one the most important sources of information about the physical properties of those objects. However, such radio observations are affected by various types of noise such as those from sky, background, receiver, and the system itself. Therefore, it is essential to eliminate or reduce these undesired noise from the signals in order to ensure accurate measurements and analysis of radio observations. One of the most commonly used methods for reducing the noise is to use a noise calibrator. In this study, the 3-m Baghdad University Radio Telescope (BURT) has been used to observe crab nebula with and without using a calibration unit in order to investigate its impact on the signal. Radio observations of crab nebula have been carried out for different periods in 2022. Several parameters of the telescope have been calculated and analyzed using statistical measurements with and without using the noise calibration unit. Those parameters are receiver gain, system temperature, antenna temperature, and degree per flux unit. The results of this research revealed that the fluctuation sensitivity of BURT improved by about an order of magnitude, when the noise calibration unit is used. The root mean square error and the radiometer equation of the antenna temperature decreased to less than 33% and 10%, respectively in comparison to their initial values. In conclusion, the noise calibration unit plays a crucial role to improve the sensitivity of a radio telescope drastically.
Objectives: The study aim to evaluate nursing performance during nasogastric tube feeding in neonatal intensive care unit. Methodology: A descriptive study was carried out in Neonatal Intensive Care Unit at al–Batool Teaching Hospital, for the purpose of evaluate of quality of nursing performance for premature baby during nasogastric tube feeding in neonatal intensive care unit. The study consumed the period from 4th of December 2017 to the 24nd of April 2018, Non-probability purposive sample of (25) nurses working in the neonatal intensive care unit. The data were collected through the use of Observational instrument which consist of socio-demographic characteristics, quality of nursing care. Results: The study shows that the majority
... Show MoreIntravascular embolisation of foreign bodies (FB) is a rare, serious complication that may occur during central venous line insertion. A 39-yearold male in a critical condition presented to casualty department with a through-and-through chest gunshot wound. Chest X-ray showed left haemothorax; an urgent chest tube was introduced and central venous access was introduced via the right femoral vein. The guided wire used in the procedure was unintentionally pushed to reach the right ventricular apex. Echocardiography confirmed FB location. Once stabilised, the patient was referred to Iraqi Centre of Cardiac Diseases, where transcatheter retrieval was performed. To stabilise the FB, a 6F pigtail catheter was used to create a U-shaped loop in the
... Show MoreThe electronic characteristics, including the density of state and bond length, in addition to the spectroscopic properties such as IR spectrum and Raman scattering, as a function of the frequency of Sn10O16, C24O6, and hybrid junction (Sn10O16/C24O6) were studied. The methodology uses DFT for all electron levels with the hybrid function B3-LYP (Becke level, 3-parameters, Lee–Yang-Parr), with 6-311G (p,d) basis set, and Stuttgart/Dresden (SDD) basis set, using Gaussian 09 theoretical calculations. The geometrical structures were calculated by Gaussian view 05 as a supplementary program. The band gap was calculated and compared to the measured valu
... Show MoreThe annealing temperature (200–500 °C) effects of optical frequency response on the dielectric functions of sol–gel derived CuCoO
Manganese-zinc ferrite MnxZn1-xFe2O4 (MnZnF) powder was prepared using the sol-gel method. The morphological, structural, and magnetic properties of MnZnF powder were studied using X-ray diffraction (XRD), atomic force microscopy (AFM), energy dispersive X-ray (EDX), field emission-scanning electron microscopes (FE-SEM), and vibrating sample magnetometers (VSM). The XRD results showed that the MnxZn1-xFe2O4 that was formed had a trigonal crystalline structure. AFM results showed that the average diameter of Manganese-Zinc Ferrite is 55.35 nm, indicating that the sample has a nanostructure dimension. The EDX spectrum revealed the presence of transition metals (Mn, Fe, Zn, and O) in Mang
... Show More