AgInSe2 (AIS) thin films solar cell involving of n-type AgInSe2 and Si of p-type substrate by using thermal evaporation method. The influence of annealing of the preparation AgInSe2 were considered to find the best properties of solar device. Thin film AIS have been deposited under the vacuum of 1.5*10-6 Torr with (400) nm thickness at R.T and annealing temperatures (473,573) K. Polycrystalline tetragonal structure for AIS thin films from XRD and increasing of surface roughness from AFM, energy gap values decreasing with increasing annealing temperatures, all films were negative type, I-V characteristics show increasing of efficiency with increasing of annealing temperatures.
Background: Tumor associated tissue eosinophilia (TATE) has been described in a variety of neoplasms. In regard to squamous cell carcinoma, some studies worldwide done to assess stromal eosinophilia in oral and cervical squamous cell carcinoma. The objectives of this study is to evaluate the association of stromal eosinophilic infiltration of cutaneous squamous cell carcinoma and to detect the significance of this association.
Aim of the study
The aim of our study is to establish the relationship between the degree of stromal eosinophilia and the level of invasion and the histological grade in cutaneous squamous cell carcinoma.
Methods: In this retrospective study
... Show MoreBackground: Tumor associated tissue eosinophilia (TATE) has been described in a variety of neoplasms. In regard to squamous cell carcinoma, some studies worldwide done to assess stromal eosinophilia in oral and cervical squamous cell carcinoma. The objectives of this study is to evaluate the association of stromal eosinophilic infiltration of cutaneous squamous cell carcinoma and to detect the significance of this association. Aim of the study The aim of our study is to establish the relationship between the degree of stromal eosinophilia and the level of invasion and the histological grade in cutaneous squamous cell carcinoma. Methods: In this retrospective study done at the histopathology department of al Wasity teaching hospital for orth
... Show MoreHigh cost of qualifying library standard cells on silicon wafer limits the number of test circuits on the test chip. This paper proposes a technique to share common load circuits among test circuits to reduce the silicon area. By enabling the load sharing, number of transistors for the common load can be reduced significantly. Results show up to 80% reduction in silicon area due to load area reduction.
Silicon nanowire arrays (SiNWs) are created utilizing the metal-assisted chemical etching method with an Ag metal as a catalyst and different etching time of 15, 30, and 60 minutes using n-Si (100). Physical properties such as structural, surface morphology, and optical properties of the prepared SiNWs are studied. The diameter of prepared SiNWs ranged from 20 to 280 nm, and the reflectance in the visible part of the wavelength spectrum was less than 1% for all prepared samples. The obtained energy gap of prepared SiNWs was around 2 eV, which is higher than the energy gap of bulk silicon. X-ray diffraction (XRD) has diffraction peaks at 68.70o for all prepared samples. The heterojunction solar cell was fabricated based on the
... Show MoreBACKGROUND: Sickle cell nephropathy, a heterogeneous group of renal abnormalities resulting from complex interactions of sickle cell disease (SCD)-related factors and non-SCD phenotype characteristics, is associated with an increased risk for morbidity and mortality. AIMS: The aims of this study were to determine the frequency of microalbuminuria (MA) among pediatric patients with SCD and to determine risk factors for MA among those patients. SUBJECTS AND METHODS: A case–control study was carried out on 120 patients with SCD, 2–18 years old, registered at Basrah Center for Hereditary Blood Diseases, and 132 age-and sex-matched healthy children were included as a control group. Investigations included complete blood panel, blood urea, se
... Show MoreAdvances in gamma imaging technology mean that is now technologically feasible to conduct stereoscopic gamma imaging in a hand-held unit. This paper derives an analytical model for stereoscopic pinhole imaging which can be used to predict performance for a wide range of camera configurations. Investigation of this concept through Monte Carlo and benchtop studies, for an example configuration, shows camera-source distance measurements with a mean deviation between calculated and actual distances of <5 mm for imaging distances of 50–250 mm. By combining this technique with stereoscopic optical imaging, we are then able to calculate the depth of a radioisotope source beneath a surfa
Wireless channels are typically much more noisy than wired links and subjected to fading due to multipath propagation which result in ISI and hence high error rate. Adaptive modulation is a powerful technique to improve the tradeoff between spectral efficiency and Bit Error Rate (BER). In order to adjust the transmission rate, channel state information (CSI) is required at the transmitter side.
In this paper the performance enhancement of using linear prediction along with channel estimation to track the channel variations and adaptive modulation were examined. The simulation results shows that the channel estimation is sufficient for low Doppler frequency shifts (<30 Hz), while channel prediction is much more suited at
... Show MoreThe goal beyond this Research is to review methods that used to estimate Logistic distribution parameters. An exact estimators method which is the Moment method, compared with other approximate estimators obtained essentially from White approach such as: OLS, Ridge, and Adjusted Ridge as a suggested one to be applied with this distribution. The Results of all those methods are based on Simulation experiment, with different models and variety of sample sizes. The comparison had been made with respect to two criteria: Mean Square Error (MSE) and Mean Absolute Percentage Error (MAPE).