Resveratrol, (RES), a phytoalexin, is well-known for its anti-inflammatory and anti-oxidant properties. SEB, a superantigen, is known to trigger ALI and cause mortality. In the current study, we tested the effect of RES in a dual-dose model of SEB exposure that triggers ALI and causes 100% mortality in C3H/HeJ-mice. The data revealed RES attenuated SEB-induced ALI and prevented mortality. Forty eight hours post-SEB exposure, lung-infiltrating mononuclear cells were tested for microRNA expression profile to determine the epigenetic regulation by resveratrol. SEB-activated splenocytes were pre-treated with 50 μM of RES or vehicle for metabolic profile analysis by measuring oxygen consumption rate (OCR) and extracellular acidification rate (ECAR). We also noted significant decline in miR-193a in the lungs of RES-treated SEB group, which targeted and caused an increase in TGFβ2 and TGFβR3, potent inhibitors of T-cell proliferation, by using RT-PCR and validation by transfection studies. RES-induced downregulation of miR-193a also influenced the activity of mechanistic target of rapamycin (mTOR) as well as pyruvate kinase muscle isozyme2 (PKM2) genes, and caused RES-treated SEB-activated T cells to be quiescent metabolically in comparison to the energetic vehicle-treated SEB-activated T cells. Together, RES caused inhibition in the proliferation of SEB-activated T-cells by alterations in miR expression and metabolic profiles. (Supported by NIH grants P01AT003961, R01AT006888, R01ES019313, R01MH094755, P20GM103641 and R01AI129788).
Background: Radiotherapy, is therapy using ionizing radiation in order to deliver an optimal dose of either particulate or electromagnetic radiation to a particular area of the body with minimal damage to normal tissues. The source of radiation may be outside the body of the patient (external beam irradiation) or it may be an isotope that has been implanted or instilled into abnormal tissue or a body cavity. Called also radiotherapy. The aim of work studies the relationship between the depth dose and the high photon xray energies (6MeV and 10MeV). Patients and methods: in our work, we studied the dose distribution in water phantom given at different depths (zero-18) cm deep at1cm intervals treated with different field size (5×5-,10×1
... Show MoreThe purpose of this study is to compare the influence of three teaching methods, as represented by problem-based learning (PBL), the PBL with lecture method, and the conventional teaching on undergraduate physics students' group work skills among bachelor’s degree physics students. In this study, the pre- and post-test were done and the instruments were administered to the students for data collection. The actual sample size comprises of 122 students, who were selected randomly from the physics department, college of education in iraq. Overall, the statistical results rejected null hypothesis of this study. Thus, using the PBL without or with lecture method enhances the skills of the group work among the bachelor’s degree physics studen
... Show MoreIn this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised
IMPLICATION OF GEOMECHANICAL EVALUATION ON TIGHT RESERVOIR DEVELOPMENT / SADI RESERVOIR HALFAYA OIL FIELD
In this paper, we calculate and measure the SNR theoretically and experimental for digital full duplex optical communication systems for different ranges in free space, the system consists of transmitter and receiver in each side. The semiconductor laser (pointer) was used as a carrier wave in free space with the specification is 5mW power and 650nm wavelength. The type of optical detector was used a PIN with area 1mm2 and responsively 0.4A/W for this wavelength. The results show a high quality optical communication system for different range from (300-1300)m with different bit rat (60-140)kbit/sec is achieved with best values of the signal to noise ratio (SNR).
Sewage pumping stations are considered an important part of any sewerage system. Pumps failure in these stations means that the pumps are unable to work at the design requirement (flow capacity and head) and that may cause sewer overflow and flooding leading to sewer deterioration. In this paper, two main sewage pumping stations in Baghdad city were selected as case studies, Al- Habibia and Al-Ghazali located on Zublin trunk sewer 3000 mm and Baghdad trunk sewer 1200-2100 respectively. This study focused mainly on the operation of main sewage pumping stations and their effect, both directly and indirectly, on changing hydraulic properties, which leads to an increase in the deterioration of sewage pipes. The hydraulic analysis was co
... Show MoreBackground: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show More