Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesisMethods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
The art of theater penetrated various scientific and human fields, as well as touching the facts and events surrounding it, and scientific innovations had a wide field, so it adopted feedback in interactive theater performances, especially the theater of the oppressed. Then came the indicators that resulted from the theoretical framework for the formation of the tool by which the research sample is analyzed, and then the chapter concluded with previous studies. As for the third chapter, it involved the research procedures, and through the research tool and the research method, and by selecting the intentional sample, the sample represented by a play (the story of Shahrour) was analyzed. As for the fourth chapter, it included the results
... Show MoreThiamine stimulates the production of a red pigment , which is chromatographically and spectrophotometrically identical to prodigiosin , by growing cultures of serratia marcescens mutant 9-3-3 . this mutant is blocked in the formation of 2- methyl -3- amyl pyrorol( MAP),the monopyrrole moiety of prodigiosin , but accumulates 4-methoxy-2, 2-bipyrrole -5- carboxaldehyde (MBC) and can couple this compound with( MAP) to form prodigiosin . Addition of thiamine caused production of( MAP) , and as little as 0.02 mg of thiamine / ml in peptone- glycerol medium stimulated production of measurable amounts of prodigiosin. Phosphate saltes and another type of peptone decreased the thiamine- induced formation of prodigiosin ,yeast extract and glyc
... Show MoreBackground: Radiation therapy reported to be an effective in palliating pain. Objective: To describe roles of palliative radiotherapy in controlling pain in metastatic cancerous patients, and evaluation of radio-therapy doses in pain management. Methods: A prospective observational study carried out at the Baghdad Radiotherapy and Nuclear Medicine Center/Baghdad Medical City Complex, Baghdad, Iraq, from 1st of December 2018 to 30th of May 2019. 88 Patients, were included. Patients were assessed before applying radiotherapy, and at the end of treatment. Pain scoring used from 0 to 10. Kaplan Meier survival curve used. Result: The mean±SD of age was 55.44±11.1 years, and the most frequent age group was 41-50years as 37(42.1%). Breas
... Show MoreA calculation have been carried out for determination some of the spectroscopic properties of Hydrogen Iodide HI molecules such as, the intensity of the absorption spectrum as a function of the variation of the temperature ranging from 10 to 1000 K. This study shows that the populations and hence intensity of the molecule increased as the temperature increased. Another determination of the maximum rotational quantum number Jmax of N2 , CO , BrF AgCl and HI molecules has been carried out.
The aim of the study is to detect the malignant conditions of the skin tumors through the features of optical images. This research included some of image processing techniques to detect skin cancer as a strong threat to human beings' lives. Using image processing and analysis methods to improves the ability of pathologists to detect this disease leading to more specified diagnosis and better treatment of them. One hundred images were collected from Benign and Malignant tumors and some appropriate image features were calculated, like Maximum Probability, Entropy, Coefficient of Variation, Homogeneity and Contrast, and using Minimum Distance method to separate these images. These features with Minimum Distance as a proposed making decision a
... Show More
The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased
... Show MoreConcrete is the main construction material of many structures. Exposing to loads creates cracks in concrete, which reduce the performance and durability. The decrease of concrete cracks becomes a necessity demand to ensure more durability and structural integrity of the concrete structure. Autogenous healing concrete is a kind of new smart concretes, which has the ability to reclose its cracks by means of itself. Concrete self-healing is a type of free repairs processes, which is reduce direct and indirect cost of maintenance and repairing. This work targets to inspect the mechanical properties of concrete after using two combinations of two materials (20 kg/m3 calcium hydroxide Ca(OH
Five new ceftazidime derivatives were designed and synthesized in an attempt to improve the acid stability and may increase the spectrum of ceftazidime. The synthesized compounds included; Schiff base of ceftazidime (compound 1), ceftazidime lysine amide Schiff base (compound 2), ceftazidime lysine amide (compound 3), ceftazidime-di-lysine amide Schiff base (compound 4) and ceftazidime-di-lysine amide (compound 5). New ceftazidime derivatives were successfully prepared characterized and identified using spectral and elemental microanalysis (CHNS) analyses and the results comply with the calculated measurements.
Compounds 1 and 2 were subjected to a stability study in phosphate buffer (0.2M, pH 7.4) and in KCl/HCl buffer (0.
... Show More