Aim and Objectives: The objective of this study was to illustrate the link between periodontitis (PO) and endothelial dysfunction in hypertensive patients. Materials and Methods: This cross‑sectional study involved 53 hypertensive patients with or without PO compared with 28 healthy controls. On the basis of the study protocol, the participants were divided into three groups: Group (1): 24 patients with hypertension only, Group (2): 29 patients with hypertension and PO, and Group (3): 28 healthy controls. Lipid profile, endothelin‑1 (ET‑1), and high‑sensitivity C‑reactive protein (hs‑CRP) were measured. Blood pressure and body mass index (BMI) were evaluated. Diagnostic criteria of severe PO periodontal indices including plaque index, gingival index, and community periodontal index were estimated. Data collected during the study were analyzed using analysis of variance followed by Bonferroni post hoc test and unpaired t‑test (IBM SPSS Statistics for Windows, version 20.0, 2014, IBM, Armonk, NY). Results: BMI was not differed in both groups, P = 0.08. Systolic blood pressure and diastolic blood pressure were high in hypertensive patients with PO compared with hypertensive patients only, P = 0.04 and P = 0.03, respectively. Moreover, hypertensive patients with PO showed significant dyslipidemic status compared with hypertensive patients only (P < 0.05). Biomarker of endothelial dysfunction (ET‑1) was elevated in patients with PO (67.54 ± 13.56 pg/mL) compared with hypertensive patients only (23.67 ± 9.63 pg/mL), P = 0.0001. hs‑CRP serum level was increased patients with PO compared with hypertensive patients only, P = 0.002. PO indices were high in patients with PO compared with hypertensive patients only, P < 0.01. Conclusion: ET‑1 serum level is elevated in hypertensive patients with severe PO and correlated with cardio‑metabolic complications, mainly endothelial dysfunction. Therefore, ET‑1 serum level is regarded as a surrogate biomarker link PO with risk of endothelial dysfunction.
The preparation of composite metal oxide to attain high efficiency in removing phenol from wastewater has a great concern. In the present study, the focus would be on adopting antimony-tin oxide coating onto graphite substrates instead of titanium; besides the effect of SbCl3 concentration on the SnO2-Sb2O3 composite would be examined. The performance of this composite electrode as the working electrode in the removal of phenol by sonoelectrochemical oxidation will be studied. The antimony-tin dioxide composite electrode was prepared by cathodic deposition with SnCl2 . 2H2O solution in a mixture of HNO3 and NaNO3, with different concentrations of SbCl3. The SnO2-Sb2O3 deposit layer’s structure and morphology were examined and the 4 g/l Sb
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri
... Show MoreBackground: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri
... Show MoreBackground: Debonding and fracture of artificial teeth from denture bases are common clinical problem, bonding of artificial teeth to heat cure acrylic and high impact heat cure acrylic denture base materials with autoclave processing method is not well known. The aim of this study was to evaluate the effect of autoclave processing method on shear bond of artificial teeth to heat cure denture base material and high impact heat cure denture base material. Materials and methods: Heat polymerized (Vertex) and high impact acrylic (Vertex) acrylic resins were used. Teeth were processed to each of the denture base materials after the application of different surface treatments. The sample (which consist of artificial tooth attached to the dentur
... Show Moreتم تحضير ثلاث معقدات جديدة Ni (II)و Cu (II) و Zn (II) باستخدام الليكند المحضر الجديد من تفاعل حامض مالونيك ثنائي هيدرازايد مع 2-بيريدين كربوكسالديهايد. حيث شخصت المعقدات لمحضرة وكذلك الليكند باستخدام تقنيات مختلفة مثل FT-IR و UV-Vis و Mass و 1H-NMR و 13C-NMR وتحليل العناصر CHN و تقدير محتوى الكلور والموصلية المولارية والحساسية المغناطيسية والامتصاص الذري لتشخيص هذه المركبات. لكل معقد محضر جديد من النيكل والنحاس والزنك ، كشفت نتائج ا
... Show MoreTraumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at leas
... Show MoreThe simulation have been made for 3D flow structure and heat transfer with and without
longitudinal riblet upstream of leading edge vane endwall junction of first stage nozzle guide vane .The research explores concept of weakening the secondary flows and reducing their harmful effects.Numerical investigation involved examination of the secondary flows ,velocity and heat transfer rates by solving the governing equations (continuity, Navier -stokes and energy equations ) using the known package FLUENT version (12.1).The governing equations were solved for three dimentional, turbulent flowe, incompressible with an appropriate turbulent model (k-ω,SST) .The numerical solution was carried out for 25 mode
... Show More