Aim and Objectives: The objective of this study was to illustrate the link between periodontitis (PO) and endothelial dysfunction in hypertensive patients. Materials and Methods: This cross‑sectional study involved 53 hypertensive patients with or without PO compared with 28 healthy controls. On the basis of the study protocol, the participants were divided into three groups: Group (1): 24 patients with hypertension only, Group (2): 29 patients with hypertension and PO, and Group (3): 28 healthy controls. Lipid profile, endothelin‑1 (ET‑1), and high‑sensitivity C‑reactive protein (hs‑CRP) were measured. Blood pressure and body mass index (BMI) were evaluated. Diagnostic criteria of severe PO periodontal indices including plaque index, gingival index, and community periodontal index were estimated. Data collected during the study were analyzed using analysis of variance followed by Bonferroni post hoc test and unpaired t‑test (IBM SPSS Statistics for Windows, version 20.0, 2014, IBM, Armonk, NY). Results: BMI was not differed in both groups, P = 0.08. Systolic blood pressure and diastolic blood pressure were high in hypertensive patients with PO compared with hypertensive patients only, P = 0.04 and P = 0.03, respectively. Moreover, hypertensive patients with PO showed significant dyslipidemic status compared with hypertensive patients only (P < 0.05). Biomarker of endothelial dysfunction (ET‑1) was elevated in patients with PO (67.54 ± 13.56 pg/mL) compared with hypertensive patients only (23.67 ± 9.63 pg/mL), P = 0.0001. hs‑CRP serum level was increased patients with PO compared with hypertensive patients only, P = 0.002. PO indices were high in patients with PO compared with hypertensive patients only, P < 0.01. Conclusion: ET‑1 serum level is elevated in hypertensive patients with severe PO and correlated with cardio‑metabolic complications, mainly endothelial dysfunction. Therefore, ET‑1 serum level is regarded as a surrogate biomarker link PO with risk of endothelial dysfunction.
Polycrystalline Cadmium Oxide (CdO) thin films were prepared using pulsed laser deposition onto glass substrates at room temperature with different thicknesses of (300, 350 and 400)nm, these films were irradiated with cesium-137(Cs-137) radiation. The thickness and irradiation effects on structural and optical properties were studied. It is observed by XRD results that films are polycrystalline before and after irradiation, with cubic structure and show preferential growth along (111) and (200) directions. The crystallite sizes increases with increasing of thickness, and decreases with gamma radiation, which are found to be within the range (23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for thickness 350nm and 4
... Show MoreEpithelial ovarian cancer is the leading cause of cancer deaths in women. To date, an effective screening tool for ovarian cancer has not been identified Several clinical and biological factors including serum cancer antigen 125 (CA- 125) have been assessed for prognostic and predictive relevance CA-125 is an epithelial marker derived from coelomic epithelium. It is elevated in 90% of advanced ovarian cancers and in 50% of early ovarian cancers while 20% of ovarian cancers have low or no expression of CA- 125 CA-125 concentrations were measured by Mini Vidas test (VIDAS CA125 II / BIOMERIEUX / France). The median CA-125 levels were significantly higher in the sera of ovarian cancer patients than in those with benign tumors an
... Show MoreComplexes of (Co2+, Ni2+, Cu2+, Zn2+, Cd2+ and Hg2+) with the ligand Ethyl cyano (2-methyl carboxylate phenyl azo acetate) (ECA) have been prepared and characterized by FTIR, (UV-Visible), Atomic absorption spectroscopy, Molar conductivity measurements and magnetic moments measurements. The following general formula has been suggested for the prepared complexes [M(ECA)2]Cl2 where M = (Co2+, Ni2+, Cu2+ ,Zn2+, Cd2+, Hg2+) and the geometry is octahedral.
In the present article, mixed ligand metal (II) complexes have been synthesized with Schiff base (1E, 5Z, 6E)-1,7 bis (4-hydroxy-3- methoxyphenyl)-5-(3-hydroxyphenyl) imino) hepta-1,6-dien-3-one derived from Curcumin and 3-aminophenol as primary ligand and L-dopa as a secondary ligand. The Schiff base act as bidentate and arrange to the metals through the azomethine (C=N) nitrogen and (C=O) oxygen atom. The mode of bonding of the Schiff base has been affirmed on the infrared by the UV-Visible, 1H, and 13C NMR spectroscopic techniques. The magnetic susceptibility and the UV-Vis data of the complexes propose octahedral geometry around the central metal ion. The information appears that the complexes have the structure of [L-M-(L-dopa)] system
... Show Morewell log analysis is used to determine the rock properties like porosity, water saturation, and shale volume. Archie parameters in Archie equation, which sometimes considered constants greatly affect the determination of water saturation, also these parameters may be used to indicate whether the rocks are fractured or not so they should be determined. This research involves well logging analysis for Zubair formation in Luhais field which involves the determination of Archie parameters instead of using them as constant.
The log interpretation proved that the formation is hydrocarbon reservoir, as it could be concluded from Rwa (high values) and water saturation values (low values), the lithology of Zubair from cro
... Show MoreThis effort is related to describe and assess the performance of the Iraqi cement sample planned for oil well-cementing jobs in Iraq. In this paper, major cementing properties which are thickening time, compressive strength, and free water in addition to the rheological properties and filtration of cement slurry underneath definite circumstances are experimentally tested. The consequences point to that the Iraqi cement after special additives encounter the requests of the API standards and can consequently is used in cementing jobs for oil wells. At this research, there is a comparative investigation established on experimental work on the effectiveness of some additives that considered as waste materials which are silica fume, bauxite,
... Show MoreThin films ZrO2: MgO nanostructure have been synthesized by a radio frequency magnetron plasma sputtering technique at different ratios of MgO (0,6, 8 and 10)% percentage to be used as the gas sensor for nitrogen dioxide NO2. The samples were investigated by X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) and sensing properties were also investigated. The average particle size of all prepared samples was found lower than 33.22nm and the structure was a monoclinic phase. The distribution of grain size was found lower than36.3 nm and uninformed particles on the surface. Finally, the data of sensing properties have been discussed, where the
... Show MoreIn the present study, activated carbon supported metal oxides was prepared for thiophene removal from model fuel (Thiophene in n-hexane) using adsorptive desulfurization technique. Commercial activated carbon was loaded individually with copper oxide in the form of Cu2O/AC. A comparison of the kinetic and isotherm models of the sorption of thiophene from model fuel was made at different operating conditions including adsorbent dose, initial thiophene concentration and contact time. Various adsorption rate constants and isotherm parameters were calculated. Results indicated that the desulfurization was enhanced when copper was loaded onto activated carbon surface. The highest desulfurization percent for Cu2O/AC and o
... Show MoreBackground: acrylic resin denture base consider a common denture base material for its acceptable cost, aesthetic and easy processing but still has disadvantages including easy of fracture and low impact strength. Material and method: The experimental group was prepared by addition of 15% phosphoric acid 2-hydroxyethyl methacrylate ester (PA2HEME) with polymethyl methacrylate monomer; the experimental groups was compared with the control one. The specimens were prepared according to ADA specification No. 12 with dimension 65 mm x 10 mm x2.5 mm (length x width x thickness respectively). The prepared specimens were tested by three-point flexural strength utilizing Instron Universal Testing Machine (WDW, Layree Technology Co.), Shore D hard
... Show More