Background: Orthodontic treatment with fixed appliances is frequently associated with difficulties in maintaining good oral hygiene and creation of plaque-retentive areas on tooth surfaces that are typically more prone to the development of caries; such drawbacks may result in white spot lesion (WSL) development that affects the esthetic outcome following bracket debonding. This review article focuses on orthodontic WSLs development, prevention, and remineralization potential via incorporating various remineralizing / antibacterial additives into orthodontic adhesives. Results: Unbalanced enamel demineralization and remineralization processes, along with rapid alterations in the dental plaque bacterial ecology, particularly acidogenic bacteria, are the causes of the start and progression of a carious lesion. Without significantly compromising an adhesive mechanical performance, several antibacterial and remineralizing substances have been added to orthodontic adhesives in an effort to reduce bacterial colonization and promote remineralization. Conclusions: Antibacterial and/or remineralizing substances were utilized as additives in the creation of innovative orthodontic adhesive systems to address white spot lesions (WSLs) and improve the ability of enamel remineralization. Compared to adding only one agent, including multiple agents in an orthodontic adhesive system may have a greater impact on lowering enamel demineralization and improving enamel remineralization during orthodontic therapy.
Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bila
... Show MoreOsteoporosis is a global health concern with bone frailty and high fracture risk. Existing diagnostic paradigms largely rely on bone scanning and bone mineral density evaluation which are hindered by the delayed prediction of fractures, especially in high-risk groups. This review assesses existing and novel Osteoporosis biomarkers, their mechanisms, clinical efficacy, drawbacks, and discusses the best biomarkers in Osteoporosis risk stratification and management, to convert them into better patient care. An online search was conducted, including PubMed, Web of Science, Embase, and Google Scholar up to June 2026. Passed studies were reviewed critically and organized biomarkers into five different panels: traditional and bone turnover
... Show MoreFifteen local isolates of Pseudomonas were obtained from several sources such as soil, water and some high-fat foods (Meat, olives, coconuts, etc.). The ability of isolates to produce lipase was measured by the size of clear zone on Tween 20 solid medium and by measuring the enzymatic activity and specific activity. Isolate M3 (as named in this study) was found to be the most efficient for the production of the lipase with enzymatic activity reached 56.6 U/ml and specific activity of 305.94 U/mg. This isolate was identified through genetic analysis of the 16S rRNA gene. and it was shown that the isolate M3 belongs to Pseudomonas aeruginosa with 99% similarity. The DNA of isolate M3 was extracted and lipase gene was amplified through PCR tec
... Show MoreThis research deals with study of the effect of additives on rheological properties (yield point, plastic viscosity ,and apparent viscosity) of emulsions. Twenty seven emulsion samples were prepared; all emulsions in this investigation are invert emulsions when water droplets are dispersed in diesel oil. The resulting emulsions are called water-in-oil (W/O) emulsions. The rheological properties of these emulsions were investigated using a couett coaxial cylinder rotational viscometer (Fann-VG model 35 A), by measuring shear stress versus shear rate. It was found that the effect of additives on rheological properties of emulsions as follow: the increase in the concentration of asphaltic material tends to increase the rheological propertie
... Show MoreThis research deals with the effects of welding variables using MIG/MAG spot by using Argon (Ar) gas and CO2 to show their effect on the mechanical characteristics and microstructure of low alloy steel type DIN15Mo3 and determine the optimum condition for the process of welding ; current & time. The results show the possibility of using CO2 and also Ar in low alloy steel welding with a little decrease in the shear force of not more than 13% for 4mm thickness and time 2sec. The shear force increased when using Ar instead of CO2 to be , The shear force reach 36KN when using Ar at 2mm thickness time of 8 sec and current of 220 Amp. , when used CO2 instead of Ar d
... Show MoreThe parameters of resistance spot welding (RSW) performed on low strength commercial aluminum sheets are investigated experimentally, the performance requirements and weldability issues were driven the choice of a specific aluminum alloy that was AA1050. RSW aluminum alloys has a major problem of inconsistent quality from weld to weld comparing with welding steel
alloys sheet, due to the higher thermal conductivity, higher thermal expansion, narrow plastic temperature range, and lower electrical resistivity. Much effort has been devoted to the study of describing the relation between the parameters of the process (welding current, welding time, and electrode force) and weld strength. Shear-tensile strength tests were performed to ind
An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.
Background/Objectives: This study evaluates the diagnostic and referral skills of final-year dental students at Al-Iraqia University using a questionnaire based on malocclusion cases ranging from mild to severe. Methods: The questionnaire, featuring photos and radiographs of five selected treated cases from two textbooks, was answered by 165 students who were asked to assess each case and determine whether orthodontic or surgical treatment was necessary, as well as to identify factors contributing to an unesthetic profile, such as irregular teeth. Frequency distribution and the Chi-square test were used for statistical analysis. Results: The results indicated good overall clinical competence. The unesthetic profile and irregular tee
... Show MoreBackground: The formation of white spot lesions around fixed orthodontic attachments is a common complication during and after fixed orthodontic treatment, which hinders the result of a successfully completed orthodontic treatment. The aim of the study was to assess the effectiveness of the Caries Infiltrant (ICON®) on prevention of caries on the smooth enamel surface when applied alone or combined with conventional adhesives. Materials and methods: Seventy eight human premolar enamel discs were randomly assigned to six groups (n=13). The discs were etched and treated with resins of different monomer content forming the following groups: (1)Untreated etched samples served as the negative control, (2) ICON® (DMG), (3) Adper™ S
... Show More