Preferred Language
Articles
/
8RewPpIBVTCNdQwC7Kjp
Evaluating the effect of ursodeoxycholic acid (UDCA) in comparison with dexamethasone and diclofenac in a rat model of rheumatoid arthritis
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Fabrication of Copper-Graphite MMCs Using Powder Metallurgy Technique
...Show More Authors

Copper, and its, alloys and composites (being the matrix), are broadly used in the electronic as well as bearing materials due to the excellent thermal and electrical conductivities it has.

In this study, powder metallurgy technique was used for the production of copper graphite composite with three volume perc ent of graphite.  Processing parameters selected is (900) °C sintering temperature and (90) minutes holding time for samples that were heated in an inert atmosphere (argon gas). Wear test results showed a pronounced improvement in wear resistance as the percent of graphite increased which acts as solid lubricant (where wear rate was decreased by about 88% as compared with pure Cu). Microhardness and

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Physical Properties of Cu Doped ZnO Nanocrystiline Thin Films
...Show More Authors

Thin films of ZnO nano crystalline doped with different concentrations (0, 6, 9, 12, and 18 )wt. % of copper were deposited on a glass substrate via pulsed laser deposition method (PLD). The properties of ZnO: Cu thin-nanofilms have been studied by absorbing UV-VIS, X-ray diffraction (XRD) and atomic force microscopes (AFM). UV-VIS spectroscopy was used to determine the type and value of the optical energy gap, while X-ray diffraction was used to examine the structure and determine the size of the crystals.  Atomic force microscopes were used to study the surface formation of precipitated materials. The UV-VIS spectroscopy was used to determine the type and value of the optical energy gap.

View Publication Preview PDF
Scopus (13)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Jan 30 2026
Journal Name
Iraqi Journal Of Science
Square root of fuzzy QS-ideals on QS-algebras
...Show More Authors

In real-life problems, we use square roots in natural distributions such as (the probability density function), distances and lengths in the Pythagorean theorem, and quadratic formulas in (the height of falling objects), radius of circles, harmonic movements (pendulum and springs), and standard deviation in statistics. We have observed that using fuzzy sets in real-life problems is more convenient than ordinary sets. Therefore, they are important in algebraic structures. As a result, more effort has been made to study square root structures in fuzzy sets. This paper introduces the notion of square roots fuzzy of QS-ideals on QS-algebras and some important characteristics. Some illustrative examples have been provided which prove tha

... Show More
View Publication
Crossref
Publication Date
Tue Aug 02 2022
Journal Name
Basic And Clinical Andrology
Effects of Covid-19 vaccination on different semen parameters
...Show More Authors
Abstract<sec> <title>Background

The possible effects of COVID-19 vaccines on reproductive health and male fertility in particular have been discussed intensely by the scientific community and the public since their introduction during the pandemic. On news outlets and social media platforms, many claims have been raised regarding the deleterious effects of COVID-19 vaccines on sperm quality without scientific evidence. In response to this emerging conflict, we designed this study to evaluate and assess the effect of the Pfizer-BioNTech mRNA COVID-19 vaccine on male fertility represented by the semen analysis parameters.

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Colloid And Interface Science
Wettability alteration of oil-wet carbonate by silica nanofluid
...Show More Authors

Changing oil-wet surfaces toward higher water wettability is of key importance in subsurface engineering applications. This includes petroleum recovery from fractured limestone reservoirs, which are typically mixed or oil-wet, resulting in poor productivity as conventional waterflooding techniques are inefficient. A wettability change toward more water-wet would significantly improve oil displacement efficiency, and thus productivity. Another area where such a wettability shift would be highly beneficial is carbon geo-sequestration, where compressed CO2 is pumped underground for storage. It has recently been identified that more water-wet formations can store more CO2. We thus examined how silica based nanofluids can induce such a wettabil

... Show More
View Publication Preview PDF
Crossref (389)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Software Engineering And Computer Systems
Practical Adoptions of T-Way Strategies for Interaction Testing
...Show More Authors

View Publication
Scopus (10)
Crossref (2)
Scopus Crossref
Publication Date
Sat Oct 31 2020
Journal Name
International Journal Of Intelligent Engineering And Systems
Speech Emotion Recognition Using MELBP Variants of Spectrogram Image
...Show More Authors

View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Crossref
Publication Date
Wed Jan 01 2003
Journal Name
Turkish Journal Of Chemistry
Gas Chr Gas Chromatographic Separ aphic Separation of Phenol Deriv ation of Phenol Derivatives by Schiff- y SchiffBase Liquid Crystalline Stationary Phases
...Show More Authors

The chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other

... Show More
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
GEOMETRY OPTIMIZATION OF COUPLING ALLIN -METFORMIN USING DFT/B3LYP MOLECULAR MODELLING TECHNIQUE: GEOMETRY OPTIMIZATION OF COUPLING ALLIN -METFORMIN USING DFT/B3LYP MOLECULAR MODELLING TECHNIQUE
...Show More Authors

This researchpaper includes the incorporation of Alliin at various energy levels and angles 

With Metformin using Gaussian 09 and Gaussian view 06. Two computers were used in this work. Samples were generated to draw, integrate, simulate and measure the value of the potential energy surface by means of which the lowest energy value was (-1227.408au). The best correlation compound was achieved between Alliin and Metformin through the low energy values where the best place for metformin to b

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.: SYNTHESIS OF NEW LEVOFLOXACIN SELECTIVE MEMBRANE SENSOR BASED ON MOLECULARLY IMPRINTED POLYMERS.
...Show More Authors

Two molecular imprinted polymer (MIP) membranes for Levofloxacin (LEV) were prepared based on PVC matrix. The imprinted polymers were prepared by polymerization of styrene (STY) as monomer, N,N methylene di acrylamide as a cross linker ,benzoyl peroxide (BPO) as an initiator and levofloxacin as a template. Di methyl adepate (DMA) and acetophenone (AOPH) were used as plasticizers , the molecular imprinted membranes and the non molecular imprinted membranes were prepared.  The slopes and detection limits of the liquid electrodes ranged from -21.96 – -19.38 mV/decade and 2×10-4M- 4×10-4M, and Its response time was around 1 minute, respectively. The liquid  electrodes were packed with 0.1 M standar

... Show More
View Publication Preview PDF