Doppler assessment may lead to intervention that reduces the risk of fetal brain damage. Aim of thestudy: to assess the relation between ultrasonic hemodynamic Doppler indices of middle cerebral and umbilical arteries (PI, RI), growth indices to immediate neonatal outcomes (weight, head & abdominal circumference, APGAR scores at 1 and 5 minutes and neonatal unit admission) in women with mild, moderate and severe anemia during pregnancy. Present study is a clinical prospective study carried out in Al-Elwiya Maternity Teaching Hospital during (January-Jun) 2019, all anemic pregnant women presented to Obstetrical wards in hospitals for emergency cesarean section were the study population. The final sample selected was 120 pregnant women. Ultrasound Doppler velocimetry measurements like middle cerebral artery-peak systolic velocity (MCA-PSV), middle cerebral artery-pulsatility index (MCA-PI), middle cerebral artery-resistance index (MCA-PR), umbilical artery-pulsatility index (UA-PI), umbilical artery- resistance index (UA-RI), middle cerebral artery to umbilical artery- resistance index ratio (MCA/UA-RI) and middle cerebral artery to umbilical artery- pulsatility index ratio (MCA/UA-PI) were measured. Neonates with less than7had low vital activities (appearance, pulse, grimace, activity, and respiration). Mean MCA-PI of anemic pregnant women with severe anemia was 1.4ms which was significantly lower than pregnant women with mild and moderate anemia, also mean MCA/UA-PI of anemic pregnant women with severe anemia was significantly lower than mild and moderate anemia with p-value <0.001. as well as the Mean neonatal HC of anemic pregnant women with severe anemia 30 cm which was significantly lower than HC of pregnant women with mild and moderate anemia (p=0.04), also mean neonatal AC of pregnant women with mild, moderate and severe, Current study showed no statistical difference in Apgar scores between the studies group, The validity results of MCA/UA-PI ratio regarding neonatal HC of anemic pregnant women are Sensitivity (22.2%), specificity (41.7%). Severe maternal anemia is found significantly associated with abnormal Doppler study middle cerebral artery to umbilical artery pulsatility index. so Doppler middle cerebral artery to umbilical artery pulsatility index has limited validity in the prediction of neonatal outcomes in anemic pregnant women.
In this paper, a new equivalent lumped parameter model is proposed for describing the vibration of beams under the moving load effect. Also, an analytical formula for calculating such vibration for low-speed loads is presented. Furthermore, a MATLAB/Simulink model is introduced to give a simple and accurate solution that can be used to design beams subjected to any moving loads, i.e., loads of any magnitude and speed. In general, the proposed Simulink model can be used much easier than the alternative FEM software, which is usually used in designing such beams. The obtained results from the analytical formula and the proposed Simulink model were compared with those obtained from Ansys R19.0, and very good agreement has been shown. I
... Show MoreBecause the Coronavirus epidemic spread in Iraq, the COVID-19 epidemic of people quarantined due to infection is our application in this work. The numerical simulation methods used in this research are more suitable than other analytical and numerical methods because they solve random systems. Since the Covid-19 epidemic system has random variables coefficients, these methods are used. Suitable numerical simulation methods have been applied to solve the COVID-19 epidemic model in Iraq. The analytical results of the Variation iteration method (VIM) are executed to compare the results. One numerical method which is the Finite difference method (FD) has been used to solve the Coronavirus model and for comparison purposes. The numerical simulat
... Show MoreIn this work, Co-Y-oxide Nano Structure is successfully synthesized via hydrothermal method. The XRD analysis, SEM analysis, optical, electrical and photo sensing properties have been investigated for Co3O4 and Co-Y-oxide thin films. The X-ray diffraction (XRD) analysis reveals that all films are polycrystalline in nature, having cubic structure. The SEM images of thin films clearly indicates that Co3O4 possesses nanosphere like structure and flower like for Co-Y-oxide. The optical properties show that the optical energy gap follows allowed direct electronic transition calculated using Tauc equation and it increases for Co-Y-oxide. The photo sensing properties of thin films are investigated as a function of time at different wavelengths to
... Show MoreDevelopments are carried out to enhance the performance of vertical axis wind turbines (VAWT). This paper studies the performance of the ducted wind turbine with convergent duct (DAWT). Basically, the duct technique is utilized to provide the desired wind velocity facing the turbine. Methodology was developed to estimate the decisive performance parameter and to present the effect of the convergent duct with different inlet angles. The ducted wind turbine was analyzed and simulated using MATLAB software and numerically using ANSYS-Fluent 17.2. Result of both approaches were presented and showed good closeness for the two cases of covering angles 12 and 20 respectively. Results also showed that the convergent duct with an inlet angl
... Show MoreImpact strength of self-compacted concrete is a field of interest, mostly when the concrete is produced from sustainable materials. This research's main objective is to clarify the ability to use two types of Portland limestone cement (Karasta and Tasluja) in self compacted concrete under impact loading, further to the economic and environmental benefits of the limestone cement. The impact loading was applied by a low-speed test, using the drop ball on concrete. Moreover, the study reveals the resistance of the grids reinforced concrete to impact loading by using polymer grid, and steel grid reinforced concrete slabs. Mixes reinforced by steel mesh had the highest results, indicating that the steel mesh was more robust because it had
... Show MoreIn this work, the switching nonlinear dynamics of a Fabry-Perot etalon are studied. The method used to complete the solution of the differential equations for the nonlinear medium. The Debye relaxation equations solved numerically to predict the behavior of the cavity for modulated input power. The response of the cavity filled with materials of different response time is depicted. For a material with a response time equal to = 50 ns, the cavity switches after about (100 ns). Notice that there is always a finite time delay before the cavity switches. The switch up time is much longer than the cavity build-up time of the corresponding linear cavity which was found to be of the order of a few round-trip ti
... Show MoreIn this paper, a least squares group finite element method for solving coupled Burgers' problem in 2-D is presented. A fully discrete formulation of least squares finite element method is analyzed, the backward-Euler scheme for the time variable is considered, the discretization with respect to space variable is applied as biquadratic quadrangular elements with nine nodes for each element. The continuity, ellipticity, stability condition and error estimate of least squares group finite element method are proved. The theoretical results show that the error estimate of this method is . The numerical results are compared with the exact solution and other available literature when the convection-dominated case to illustrate the effic
... Show MoreBackground: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hosp
... Show More