Doppler assessment may lead to intervention that reduces the risk of fetal brain damage. Aim of thestudy: to assess the relation between ultrasonic hemodynamic Doppler indices of middle cerebral and umbilical arteries (PI, RI), growth indices to immediate neonatal outcomes (weight, head & abdominal circumference, APGAR scores at 1 and 5 minutes and neonatal unit admission) in women with mild, moderate and severe anemia during pregnancy. Present study is a clinical prospective study carried out in Al-Elwiya Maternity Teaching Hospital during (January-Jun) 2019, all anemic pregnant women presented to Obstetrical wards in hospitals for emergency cesarean section were the study population. The final sample selected was 120 pregnant women. Ultrasound Doppler velocimetry measurements like middle cerebral artery-peak systolic velocity (MCA-PSV), middle cerebral artery-pulsatility index (MCA-PI), middle cerebral artery-resistance index (MCA-PR), umbilical artery-pulsatility index (UA-PI), umbilical artery- resistance index (UA-RI), middle cerebral artery to umbilical artery- resistance index ratio (MCA/UA-RI) and middle cerebral artery to umbilical artery- pulsatility index ratio (MCA/UA-PI) were measured. Neonates with less than7had low vital activities (appearance, pulse, grimace, activity, and respiration). Mean MCA-PI of anemic pregnant women with severe anemia was 1.4ms which was significantly lower than pregnant women with mild and moderate anemia, also mean MCA/UA-PI of anemic pregnant women with severe anemia was significantly lower than mild and moderate anemia with p-value <0.001. as well as the Mean neonatal HC of anemic pregnant women with severe anemia 30 cm which was significantly lower than HC of pregnant women with mild and moderate anemia (p=0.04), also mean neonatal AC of pregnant women with mild, moderate and severe, Current study showed no statistical difference in Apgar scores between the studies group, The validity results of MCA/UA-PI ratio regarding neonatal HC of anemic pregnant women are Sensitivity (22.2%), specificity (41.7%). Severe maternal anemia is found significantly associated with abnormal Doppler study middle cerebral artery to umbilical artery pulsatility index. so Doppler middle cerebral artery to umbilical artery pulsatility index has limited validity in the prediction of neonatal outcomes in anemic pregnant women.
Polyacrylonitrile nanofiber (PANFS), a well-known polymers, has been extensively employed in the manufacturing of carbon nanofibers (CNFS), which have recently gained substantial attention due to their excellent features, such as spinnability, environmental friendliness, and commercial feasibility. Because of their high carbon yield and versatility in tailoring the final CNFS structure, In addition to the simple formation of ladder structures through nitrile polymerization to yield stable products, CNFS and PAN have been the focus of extensive research as potential production precursors. For instance, the development of biomedical and high-performance composites has now become achievable. PAN homopolymer or PAN-based precursor copolymer can
... Show MoreAbstract
This study came to clarify the redemption in terms of being a method and a subject of knowledge that has its causes, controls, etiquette and scientific implications for Muslim scholars.
The science of redemption has a historical extension, starting from the era of the Companions - may God be pleased with them - and through the stages of codification and classification of works in an effort to document it and diversify its methods at the inductive, analytical, critical and argumentative levels, and to determine its causes and from the completion of the research conclude it with evidence of its scientific effects because it is a science that enriched the Islamic library in general, and hadith in particular.
For the most reliable and reproducible results for calibration or general testing purposes of two immiscible liquids, such as water in engine oil, good emulsification is vital. This study explores the impact of emulsion quality on the Fourier transform infrared (FT-IR) spectroscopy calibration standards for measuring water contamination in used or in-service engine oil, in an attempt to strengthen the specific guidelines of ASTM International standards for sample preparation. By using different emulsification techniques and readily available laboratory equipment, this work is an attempt to establish the ideal sample preparation technique for reliability, repeatability, and reproducibility for FT-IR analysis while still considering t
... Show MoreBackground: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods
... Show MoreIn this work, diamond-like carbon (DLC) thin films were prepared from Cyclohexane. Thin films were deposited on quartz substrate by atmospheric pressure Argon plasma jet system. The plasma jet system was applying high voltage sinusoidal waves of frequency 28 kHz and potential difference of 7.5kV peak to peak across the electrodes. The effect of annealing at 400, 500 and 600 °C under vacuum for two hours on optical properties and structural properties of the DLC thin films were investigated. This effect was clarified by X-ray diffraction (XRD), FTIR, UV-Visible absorption, Scanning Electron Microscopy (SEM) and Raman Spectroscopy. The X-ray diffraction patterns for the annealing DLC thin films show two broad peaks at 2θ, 26.62° and 51.58
... Show More<p>Analyzing X-rays and computed tomography-scan (CT scan) images using a convolutional neural network (CNN) method is a very interesting subject, especially after coronavirus disease 2019 (COVID-19) pandemic. In this paper, a study is made on 423 patients’ CT scan images from Al-Kadhimiya (Madenat Al Emammain Al Kadhmain) hospital in Baghdad, Iraq, to diagnose if they have COVID or not using CNN. The total data being tested has 15000 CT-scan images chosen in a specific way to give a correct diagnosis. The activation function used in this research is the wavelet function, which differs from CNN activation functions. The convolutional wavelet neural network (CWNN) model proposed in this paper is compared with regular convol
... Show MoreIn this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption. No significant effect of initial Cd concentration on the removal efficiency of cadmium b
... Show MoreIn this research, deposition of titanium oxide (TiO2) and vanadium oxide (V2O5) thin film in different mixing percentage (0, 25 ,50, 75 and100)% on the substrate of glass .The coating thickness was ( 50 nm ).
In this research contact angle was measured and the effect of weather conditions. Results showed that the value of the contact angle of the prepared films reached its highest value at 50% (TiO2+V2O5) was 160º.
The results showed that the optical transmittance of TiO2 and V2O5 thin film decrease with increasing the deposition angle and decrease with increasing V2O5 pro
... Show MoreThyroid hemiagenesis (THA) is a rare congenital anomaly in which one lobe of thyroid gland fails to develop during embryological stage. Agenesis may be unilateral, total or isthmic. Left thyroid lobe is more commonly involved than right lobe in hemiagenesis. Agenesis of the isthmus was seen in 50% of cases. Left sided hemiagenesis is more common than right sided hemiagenesis with a Left to right ratio of 4:1. Clinically patients can be euthyroid, hypothyroid or hyperthyroid. Often it is diagnosed as an incidental finding during ultrasonography (USG) study of neck, which can easily diagnose this condition.
Actual incidence of THA is unknown; most cases are diagnosed in patients admitted for thyroid scan or thyroid surgery because
... Show More