This paper proposes a hybrid speech enhancement estimator that integrates the Perceptually-motivated Karhunen–Loève Transform (PKLT) with the Dual-Masking Harmonic-based (DMH) algorithm in a unified framework termed PKDMH. The main novelty lies in combining perceptual subspace projection with harmonic-residual suppression, enabling the system to jointly remove noise while preserving speech-relevant spectral cues. PKLT first performs perceptual subspace projection and suppresses inaudible components, after which DMH eliminates remaining broadband and harmonic residuals. The proposed PKDMH system was evaluated using the TIMIT dataset contaminated with five noise types: White, Pink, F16, Airport, and Car noise—across five SNR levels (−10 dB, −5 dB, 0 dB, +5 dB, +10 dB). Objective evaluation used the standard perceptual and signal-level measures of PESQ, STOI, SNRseg, Csig, Cbak and Covl. Results show that the enhanced quality of separation and speech signal ratio between enhanced signals and original target binary mask cause obvious improvements in quantity, with average PESQ gains of 1.099, 0.888 and 0.824 for White, Pink and F16 noise, respectively. These results bring out the subjective benefit of the PKDMH cascade, in terms of being a more robust enhancement approach under low SNR and acoustically varying cases.
This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u
... Show MoreFusidic acid (FA) is a well-known pharmaceutical antibiotic used to treat dermal infections. This experiment aimed for developing a standardized HPLC protocol to determine the accurate concentration of fusidic acid in both non-ionic and cationic nano-emulsion based gels. For this purpose, a simple, precise, accurate approach was developed. A column with reversed-phase C18 (250 mm x 4.6 mm ID x 5 m) was utilized for the separation process. The main constituents of the HPLC mobile phase were composed of water: acetonitrile (1: 4); adjusted at pH 3.3. The flow rate was 1.0 mL/minute. The optimized wavelength was selected at 235 nm. This approach achieved strong linearity for alcoholic solutions of FA when loaded at a serial concentrati
... Show MoreThe aim of the research is to determine the requirements for developing the technical capabilities of the agricultural extension service providers to face the effects of climatic changes in Baghdad Governorate, to achieve the goal of the research and in order to obtain the respondents’ approval of the requirements (28) requirements were identified in the light of the literature and studies related to the subject and the opinions of specialists to develop the technical capabilities of the agricultural extension service providers distributed on two axes (the ability to know the effects of climate changes, the ability to know the practices to reduce the effects of climate changes). The
Background: Large amounts of oily wastewater and its derivatives are discharged annually from several industries to the environment. Objective: The present study aims to investigate the ability to remove oil content and turbidity from real oily wastewater discharged from the wet oil's unit (West Qurna 1-Crude Oil Location/ Basra-Iraq) by using an innovated electrocoagulation reactor containing concentric aluminum tubes in a monopolar mode. Methods: The influences of the operational variables (current density (1.77-7.07 mA/cm2) and electrolysis time (10-40 min)) were studied using response surface methodology (RSM) and Minitab-17 statistical program. The agitation speed was taken as 200 rpm. Energy and electrodes consumption had been studi
... Show More