This study experimentally investigated Free-Fall Gravity Drainage (FFGD) under combination-drive conditions in a two-dimensional Hele-Shaw model representing a water-drive reservoir. An initially high gravity potential from the oil column enabled early oil drainage before aquifer support became dominant. Three water-drive strengths were tested, demonstrating that a stronger aquifer (1.15 psig) accelerated oil recovery to approximately 75% of the original oil in place (OOIP) within 60 minutes, resulting in a final recovery of 79.5%. However, this was accompanied by rapid water breakthrough after 2.5 minutes and high-water cuts exceeding 90%. In contrast, a weaker aquifer (0.725 psig) stabilized the oil–water contact, delaying water encroachment and maintaining zero water cut throughout 240 minutes, albeit with a lower ultimate recovery of 70.2%. Visual observations confirmed that a stable water crest and oil bank were preserved longer under moderate to weak aquifer pressures, extending the gravity-dominated recovery and reducing water handling requirements. Residual oil saturation was higher under weak aquifer support (27.9%) than stronger water drive (16.8%) due to a loss of gravity potential as the oil column declined and limited aquifer support. A comparative experiment in a heterogeneous system revealed approximately 22% lower ultimate recovery and water breakthrough within 5 minutes, attributed to heterogeneity promoting preferential flow, poor sweep efficiency, and early breakthrough. In contrast, the homogeneous system sustained production with no water breakthrough for 300 minutes. These insights strengthen the understanding of gravity drainage and can help guide enhanced oil recovery strategies in water-drive reservoirs.
A new tool geometry was used to achieve friction stir spot welding (FSSW) in which the shoulder was designed separately from the rotating pin, and in order to examine weldment strength through the modified tool, a lap joints of AA2024 aluminum alloy plate 1 mm thick were welded successfully by using 6 mm pin diameter and varying process parameters (rotational speeds, tool nose geometry, and depth of tool penetration in the lower welded plate). Experimental tests indicate that the maximum average tensile shear load was 3100 N at the best selected condition. Microstructure examination and micro hardness test along the spot zones were investigated as well as measuring pin penetration load. Visual inspection of the welded spot surface shows a g
... Show MoreBackground: This study report the corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy samples without coating and with hydroxyapatite, partial stabilized zirconia and mixture of partial stabilized zirconia and hydroxyapatite coating and comparison between them through electrochemical polarization tests in 37 0 C Hank's solution. Materials and methods: Electrophoretic deposition technique (EPD) was used to achieve the coating from each one of three types of the coating materials (HAP, PSZ and mixture of 50% HAP and 50%PSZ) on Cp Ti and Ti-6Al-4V alloy samples. The electrochemical corrosion test was performed when samples were exposed to Hank's solution prepared in the laboratory and the polarization potential, corrosion rate
... Show MoreOndansetron hydrochloride (ONH) is a very bitter, potent antiemetic drug used for the treatment and/or prophylaxis of chemotherapy or radiotherapy or postoperative induced emesis. The objective of this study is to formulate and evaluate of taste masked fast dissolving tablet (FDTs) of ONH to increase patient compliance.
ONH taste masked granules were prepared by solid dispersion technique using Eudragit E100 polymer as an inert carrier. Solvent evaporation and fusion melting methods were used for such preparation.
Completely taste masking with zero release of drug in phosphate buffer pH 6.8was obtained from granules prepared by solvent evaporation method using drug: polymer ratio of 1:2, from which four formulas pas
... Show MoreTwo tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min−1 (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r
Since its start spreed "Severe acute respiratory syndrome coronavirus 2" was discovered in Wuhan, China.that is chargeable COVID-19, a pandemic virus, has end up a widespread fitness hassle everywhere in the global Over 2.1 million people have been affected. We analyze serum concentration of CD4 marker and CD8 marker depend in COVID-19 sufferers, and to make clear a relationship between these variables and disorder Progression and severity For those purpose, (158) sufferers with COVID-19 (showed with the aid of using polymerase chain reaction) and (22) seemingly wholesome human beings have been protected withinside the present day examine and taken into consideration as a manipulate group. All examine population (sufferers and manipulate) h
... Show MoreObjective: To evaluate knowledge towards smoking and its relationship with lung cancer among members of
Baghdad Nursing College.
Methodology: The study comprised 100 affiliates from the College of Nursing/ University of Baghdad that
included students, teaching staff and employees. All data was collected through a structured questionnaire
prepared by the National Cancer Research Center which were answered during a scientific symposium
organized by the center on lung Cancer Awareness in March 2016.The data were analyzed by using the SPSS,
version 22
Results: The age of the respondents ranged from (19-64 years); 76% were females and only 4% were smokers.
The results showed that the mean score for the level of knowled
Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,
... Show MoreSewer system plays an essential task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be sustainable and scientifically. For this purpose, it is crucial to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. To test this methodology; a case study of al-Rusafa in Baghdad city is
... Show More